Available on working days between 9:00 am to 6:00 pm
Email us: sales2@industriaxplc.com
Available 24/7 for inquiries and support
Description
Yokogawa ANB10D-415/CU2N ESB Bus Node Unit
Configured for distributed I/O communication over the ESB Bus network in CENTUM VP and CENTUM CS 3000 systems, the Yokogawa ANB10D-415/CU2N (ANB10D ESB Bus Node Unit) provides direct physical and electrical execution of I/O module interfacing and bus-level data exchange. The unit incorporates dual-redundant AC power supply architecture, supports rack-mounted installation, and includes the /CU2N connector unit configuration for ESB Bus connectivity.
Suffix Breakdown & Model Matrix
Code
Description
ANB10D
ESB Bus Node Unit, Dual-Redundant Type
-4
Dual-redundant power supply configuration
1
100 - 120 V AC power supply
5
Basic type without explosion protection
/CU2N
Connector Unit for ESB Bus, Part No. S9562FA (2 pieces supplied)
Hardware Specifications
Parameter
Specification
Model
ANB10D-415/CU2N
Brand
Yokogawa
Origin
Japan
Product Type
ESB Bus Node Unit
Interface
ESB Bus
I/O Module Slots
8 slots
Power Supply
100 - 120 V AC
Power Redundancy
Dual-redundant
Frequency
50/60 Hz +/- 3 Hz
Power Consumption
Approx. 80 VA to 100 VA (depending on installed modules)
Withstanding Voltage
1500 V AC between power terminals and grounding terminal
Mounting
19-inch rack mounting
Weight
Approx. 10 kg
Operating Temp
0 to 50 degC
Humidity
10 to 90 % RH, non-condensing
Explosion Protection
Not provided (Basic Type)
Connector Option
/CU2N ESB Bus Connector Unit
Channel Isolation and DCS Communication Architecture
Within Yokogawa CENTUM distributed control platforms, the ANB10D functions as an ESB Bus node interface between field I/O assemblies and the control station. Signal transfer is performed through dedicated ESB Bus communication paths while maintaining electrical separation between field-side modules and control-level communication interfaces according to the installed I/O module characteristics. The dual-redundant power architecture permits continuous node operation during replacement or failure of a single power supply module, subject to system maintenance procedures and installed hardware configuration.
Frequently Asked Questions
Q: Does the ANB10D-415/CU2N support redundant power operation? A: Yes. The "-4" suffix designates a dual-redundant power supply configuration operating from a 100 - 120 V AC source.
Q: How many I/O modules can be installed in the node unit? A: The ANB10D chassis provides 8 available slots for compatible Yokogawa FIO modules.
Q: What is the function of the /CU2N option code? A: The /CU2N option supplies the ESB Bus connector unit configuration and includes S9562FA connector assemblies for ESB Bus connection.
Field Installation Guidelines
Verify rack grounding continuity before connecting AC power wiring.
Confirm node address switch settings match the configured ESB Bus network topology before energization.
Route ESB Bus communication cables separately from AC power conductors to reduce conducted electrical interference.
Tighten rack mounting hardware according to site mechanical installation standards.
Inspect connector engagement and locking mechanisms before commissioning.
During maintenance activities, follow plant procedures for redundant power supply replacement and bus communication verification.
Maintain environmental conditions within the specified operating temperature and humidity limits.