Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ADV142-P03 Yokogawa AC Digital Input Module | New & Original Stock

ADV142-P03 Yokogawa AC Digital Input Module | New & Original Stock

Product form

Yokogawa ADV142-P03 AC Digital Input Module Configured for AC discrete signal acquisition in CENTUM VP systems, the Yokogawa ADV142-P03 (ADV142 AC Digital Input... Read more

SKU: ADV142-P03
Country of origin: JAPAN

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Yokogawa ADV142-P03 AC Digital Input Module

    Configured for AC discrete signal acquisition in CENTUM VP systems, the Yokogawa ADV142-P03 (ADV142 AC Digital Input Module) provides direct physical/electrical execution. The module processes 200 to 240 VAC field inputs through 16 isolated channels with common isolation every 8 channels and supports ON/OFF state monitoring together with pushbutton edge counting functions.

    Suffix Breakdown & Model Matrix

    Model Segment Description
    ADV142 AC Digital Input Module
    -P03 200 to 240 VAC input specification variant

    Hardware Specifications

    Parameter Specification
    Model ADV142-P03
    Brand Yokogawa
    Origin Japan
    Product Type AC Digital Input Module
    Number of Channels 16
    Input Signal Type AC digital input
    Signal Isolation Common isolation every 8 channels
    Rated Input Voltage 200 to 240 VAC, 50/60 Hz
    Input ON Voltage (Peak) 160 VAC (226 V peak) to 264 VAC (373 V peak)
    Input OFF Voltage (Peak) 40 VAC (56 V peak) maximum
    Input Current (Typical) 6.2 mA per channel at 240 V / 60 Hz
    Input Current (Maximum) 9.3 mA per channel
    Input Response Time 160 ms maximum
    Minimum ON Detection Time 200 ms
    Maximum ON/OFF Cycle 2.5 Hz
    Withstanding Voltage 2 kVAC for 1 minute (signal to system), 1.35 kVAC between commons
    Power Consumption 500 mA at 5 VDC
    Weight 0.3 kg
    Dimensions Not specified in supplied data
    Operating Temp Not specified in supplied data
    Redundancy Support Dual redundant configuration supported

    Channel Isolation and DCS Signal Handling

    The ADV142-P03 implements channel grouping isolation every 8 channels to separate high-voltage AC field signals from internal control circuitry within CENTUM VP I/O architectures. The module supports discrete status acquisition for 200 to 240 VAC process contacts while maintaining electrical separation between isolated commons.

    Input processing includes ON/OFF state validation and pushbutton pulse detection for low-frequency transition monitoring up to 2.5 Hz. Isolation barriers are designed for direct integration into distributed process control cabinets where mixed-voltage field termination and grounded AC sensing loops are present.

    Frequently Asked Questions

    Q: Does the ADV142-P03 support redundant I/O operation?

    A: Yes. The module supports dual redundant configuration within compatible Yokogawa CENTUM VP system architectures.

    Q: Can the module detect short-duration pulse transitions from pushbuttons?

    A: Yes. The specified minimum ON detection time for pushbutton input processing is 200 ms, with a maximum ON/OFF cycle rate of 2.5 Hz.

    Q: What isolation structure is used for the input channels?

    A: The module provides common isolation for every 8 input channels. Signal-to-system dielectric withstand voltage is rated at 2 kVAC for 1 minute.

    Field Installation Guidelines

    • Verify field input voltage before energizing terminal circuits. The module is intended for 200 to 240 VAC discrete input signals only.

    • Maintain separation between AC input wiring and low-level analog or communication cables inside the cabinet to reduce induced noise coupling.

    • Connect cable shields according to plant grounding standards and terminate shields at a single grounding reference point where applicable.

    • Confirm backplane seating and locking engagement before applying system power in redundant node configurations.

    • Use properly rated terminal blocks and insulation spacing for high-voltage AC field wiring.

    • Perform insulation resistance checks on field loops prior to module insertion when commissioning new installations.

    Specifications

    • Brand: Yokogawa

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account