Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ABB S800 I/O DI828 3BSE069054R1 Digital Input Module

ABB S800 I/O DI828 3BSE069054R1 Digital Input Module

Product form

ABB DI828 3BSE069054R1 Digital Input Module Configured for 120 V AC/DC digital signal acquisition in ABB S800 I/O systems, the... Read more

SKU: DI828 3BSE069054R1
Country of origin: Sweden

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    ABB DI828 3BSE069054R1 Digital Input Module

    Configured for 120 V AC/DC digital signal acquisition in ABB S800 I/O systems, the ABB DI828 3BSE069054R1 (DI828 Digital Input Module) provides direct electrical monitoring of discrete input states through individually isolated channels.

    Hardware Specifications

    Parameter Specification
    Model DI828 3BSE069054R1
    Brand ABB
    Product Type Digital Input Module
    System Platform ABB S800 I/O
    Origin Sweden
    Weight 0.15 kg
    Dimensions 4.5 x 11 x 11.8 cm
    Operating Temp 0 to +55 deg C
    Storage Temp -40 to +70 deg C
    Power Consumption Input dependent, 8.5 mA at 120 V AC / 2.4 mA at 120 V DC
    Signal Specification 120 V AC/DC
    Number of Channels 16
    Signal Type Current sinking
    AC Input Voltage Range 77 to 130 V AC
    DC Input Voltage Range 75 to 130 V DC
    Input Impedance 14.2 kOhm AC / 50 kOhm DC
    Channel Isolation Individually isolated channels
    Rated Insulation Voltage 250 V
    Dielectric Test Voltage 2000 V AC
    Input Frequency Range 47 to 63 Hz
    Digital Filter Times 2.5 +/- 0.5 ms, 5 +/- 1 ms, 10 +/- 2 ms, 20 +/- 4 ms
    Analog Filter On/Off Delay 5 ms / 10 ms
    Relative Humidity 5 to 95 %, non-condensing

    Industrial Control I/O Architecture Features

    The DI828 integrates with ABB S800 I/O backplane communication structures for deterministic digital signal handling. It supports I/O density scaling through 16 input channels while maintaining individual channel isolation.

    The module uses optical isolation barriers, EMC protection components, current limiting circuits, input state LEDs, and analog filtering on each input channel. Therefore, the module separates field signal conditions from internal electronics during normal operation.

    ABB S800 I/O modules use structured backplane bus communication for controller interaction. The DI828 supports stable digital acquisition within ABB control architectures where firmware and hardware compatibility follow the configured S800 I/O system requirements.

    The module also supports voltage supervision functions. Channel 1 supervises the supply voltage condition for channels 2 to 8, while channel 16 supervises channels 9 to 15. When supervision detects voltage loss, the module reports channel errors through the ModuleBus interface and activates the Warning LED.

    Frequently Asked Questions

    Q: What input signals does the ABB DI828 3BSE069054R1 process?
    A: The DI828 processes 120 V AC/DC discrete input signals with 16 individually isolated channels. It accepts 77 to 130 V AC and 75 to 130 V DC field inputs.

    Q: Does the DI828 provide electrical isolation between input channels?
    A: Yes. Each input channel contains an optical isolation barrier and independent protection components to separate field signals.

    Q: How does voltage supervision operate on the DI828 module?
    A: Channel 1 supervises channels 2 to 8, and channel 16 supervises channels 9 to 15. If the monitored voltage disappears, the module generates channel error information through the ModuleBus.

    Field Installation Guidelines

    Install the DI828 module according to ABB S800 I/O installation requirements and verify the ModuleBus connection before applying field voltage.

    Connect field wiring with correct polarity and maintain separation between signal wiring and high-energy power conductors. Use appropriate grounding methods for cable shields where required by the control system design.

    Confirm that the connected AC/DC voltage levels remain within the specified input ranges before commissioning. Check input LEDs and ModuleBus diagnostics to validate channel operation after installation.

    Avoid routing input cables near sources of electromagnetic interference. Verify terminal connections, insulation conditions, and cabinet ventilation before placing the module into continuous service.

    Specifications

    • Brand: ABB

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems