Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

ABB AC 800M CI869 3BSE049110R1 AF 100 Communication Interface Module

ABB AC 800M CI869 3BSE049110R1 AF 100 Communication Interface Module

Product form

ABB CI869 3BSE049110R1 AF 100 Communication Interface Module The ABB CI869 3BSE049110R1, also cataloged as the CI869 AF 100 Communication... Read more

SKU: CI869K01 3BSE049110R1
Country of origin: Sweden

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 153 9592 3051

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    ABB CI869 3BSE049110R1 AF 100 Communication Interface Module

    The ABB CI869 3BSE049110R1, also cataloged as the CI869 AF 100 Communication Interface Module, operates as a dedicated hardware component for Advant Fieldbus 100 communication through twisted pair (TWP) connections within AC 800M controller platforms.

    Hardware Specifications

    Parameter Specification
    Model CI869 3BSE049110R1
    Brand ABB
    Product Type AF 100 Communication Interface Module
    System Platform ABB AC 800M / AC 160 / Connectivity Server
    Communication Protocol ABB Advant Fieldbus 100
    Communication Role Slave station
    Connector Twisted Pair (TWP)
    Transmission Speed 1.5 Mbit/s
    Line Redundancy Supported
    Module Redundancy Supported
    Hot Swap Supported
    High Integrity Controller Support Supported
    Maximum Units on CEX Bus 12
    Power Supply +24 VDC through CEX-Bus
    Power Consumption Typical 160 mA at 24 VDC
    Operating Temp 0 to +55 deg C
    Storage Temp -40 to +70 deg C
    Protection Class IP20 according to EN60529 and IEC 529
    Corrosion Protection G3 compliant to ISA 71.04
    CE Marking Yes
    WEEE Compliance Directive 2012/19/EU
    Weight 700 g including base
    Dimensions 59 mm W x 185 mm H x 127.5 mm D

    ABB CEX-Bus and AF 100 Communication Architecture

    The CI869 provides the physical and logical interface between an AC 800M controller and the ABB Advant Fieldbus 100 network. The module integrates CEX-Bus communication logic, an AF 100 communication unit, and a DC/DC converter for internal voltage distribution.

    The module receives +24 VDC input through the CEX-Bus and supplies the required operating voltage for the communication electronics. Additionally, the integrated twisted pair modem enables direct connection to AF 100 field devices and controller stations.

    The CI869 supports redundant cable configurations and redundant communication interface arrangements. Therefore, an AC 800M controller equipped with CI869 operates as an AF 100 station that exchanges process data with other AF 100 nodes.

    Backplane Bus Communication and Redundancy Functions

    The CI869 uses ABB controller expansion architecture with CEX-Bus communication handling. The module supports communication interface redundancy and line redundancy configurations for continuous fieldbus operation.

    Furthermore, the module supports hot swap operation, allowing replacement procedures within supported AC 800M configurations without complete system shutdown. The communication design maintains AF 100 slave station behavior while transferring data between connected control nodes.

    The CI869 can also operate within AC 800M High Integrity systems where communication availability and controlled system behavior are required.

    Frequently Asked Questions

    Q: What communication protocol does the CI869 3BSE049110R1 support?
    A: The CI869 supports ABB Advant Fieldbus 100 communication through twisted pair (TWP) connections with a transmission speed of 1.5 Mbit/s.

    Q: Does the CI869 support redundant communication configurations?
    A: Yes. The module supports both line redundancy and module redundancy functions when installed in compatible AC 800M configurations.

    Q: How is the CI869 powered inside the AC 800M system?
    A: The CI869 receives +24 VDC supply through the CEX-Bus and uses an internal DC/DC converter to generate required operating voltages.

    Field Installation Guidelines

    Install the CI869 module on the designated AC 800M CEX-Bus position according to the controller hardware configuration.

    Verify that the twisted pair (TWP) fieldbus wiring follows ABB fieldbus installation requirements. Maintain proper cable routing separation from high-voltage power conductors and high-frequency interference sources.

    Connect the communication shield according to the site grounding standard to minimize electrical noise coupling. Confirm that redundant fieldbus cables and redundant communication interfaces are installed according to the configured system topology.

    Before commissioning, verify the +24 VDC supply connection, CEX-Bus communication status, and AF 100 network addressing parameters.

    Specifications

    • Brand: ABB

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Send us a message!

    Do you need a large stock? Contact us.

    Collections you may also like

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account