170AAI14000 Modicon Momentum Schneider Electric Analog Input Base

170AAI14000 Modicon Momentum Schneider Electric Analog Input Base

Product form

Schneider Electric 170AAI14000 Modicon Momentum Analog Input Base The Schneider Electric 170AAI14000, also cataloged as the 170AAI14000 Analog Input Base,... Read more

SKU: 170AAI14000
Country of origin: France

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Schneider Electric 170AAI14000 Modicon Momentum Analog Input Base

    The Schneider Electric 170AAI14000, also cataloged as the 170AAI14000 Analog Input Base, operates as a dedicated hardware component for analog signal acquisition within the Modicon Momentum automation platform. It accepts voltage and current process signals, converts them into 16-bit signed data, and transfers measurement values to the controller through the Momentum I/O architecture.

    Hardware Specifications

    Parameter Specification
    Model 170AAI14000
    Brand Schneider Electric
    Series Modicon Momentum
    Product Type Analog Input Base
    Analog Input Channels 16, single-ended
    Input Ranges 4-20 mA, +/- 5 V, +/- 10 V
    Resolution 12-bit conversion, 16-bit signed data format
    Input Impedance > 2200 kOhm (voltage inputs), < 0.25 Ohm (4-20 mA)
    Input Filter Low-pass, 10 kHz
    Full Scale 16 mA (4-20 mA), 5 V (+/- 5 V), 10 V (+/- 10 V)
    Update Time 25 ms
    Absolute Accuracy +/- 0.15 % FS at 25 degC (voltage), +/- 0.25 % FS at 25 degC (current)
    Temperature Drift 30 ppm FS/degC (voltage), 60 ppm FS/degC (current)
    Channel-to-Ground Isolation 1780 VAC for 1 minute
    Supply-to-Ground Isolation 500 V for 1 minute
    Permissible Common Mode Voltage 250 VAC, 47-63 Hz; 100 VDC
    External Power Requirement +/- 30 VDC
    Power Consumption 305 mA at 24 VDC
    Maximum Power Dissipation 5.55 W
    Reverse Polarity Protection Internal
    Internal Protection 2 A slow-blow
    Associated Fuse 500 mA fast-blow
    Local Indicators 16 channel status LEDs
    Electrical Connection Two removable terminal block connectors
    Dimensions 141.5 x 125 x 47.5 mm
    Weight 0.215 kg
    Operating Temp 0 to 60 degC
    Storage Temp -40 to 85 degC
    Relative Humidity 95 % non-condensing
    Operating Altitude Up to 5000 m
    Certifications CE, UL, CSA, FM Class 1 Division 2
    Protective Treatment TC
    Origin Schneider Electric manufacturing location not specified in the supplied data

    PLC Backplane Communication and I/O Density

    The 170AAI14000 is designed for the Modicon Momentum distributed I/O platform, where analog measurement data is transferred through the Momentum backplane interface to the controller. Sixteen single-ended analog input channels provide high I/O density for distributed acquisition while maintaining independent channel status indication through front-panel LEDs. The module delivers a fixed 25 ms update period for cyclic analog data acquisition.

    Frequently Asked Questions

    Q: Does the module support both voltage and current analog inputs?

    A: Yes. The module supports +/- 5 V, +/- 10 V, and 4-20 mA analog input ranges. Input type selection is determined during system configuration.

    Q: Is channel isolation provided?

    A: The module provides 1780 VAC isolation between input channels and ground for 1 minute, and 500 V isolation between the supply and ground. The supplied specification does not indicate channel-to-channel isolation.

    Q: Can field wiring be connected through removable terminals?

    A: Yes. The module uses two removable terminal block connectors to simplify field wiring and module replacement.

    Field Installation Guidelines

    • Verify that the configured input range matches the connected field instrument before applying power.
    • Route analog signal cables separately from motor power and high-current conductors to minimize electrical interference.
    • Connect cable shields according to the plant grounding standard and avoid multiple shield grounding points unless specified by the control system design.
    • Confirm that the external supply meets the specified +/- 30 VDC requirement before energizing the module.
    • Install the specified external 500 mA fast-blow fuse and observe the internal protection limits during maintenance.
    • Maintain ambient operating conditions within the specified temperature and humidity limits.

    Specifications

    • Brand: Schneider Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems