Over 100,000 PLC, DCS, Drive, TSI & MRO Parts In Stock Learn more

140CPU67160S Schneider Electric Unity Safety Processor

140CPU67160S Schneider Electric Unity Safety Processor

Product form

Schneider Electric 140CPU67160S Unity Safety Processor Configured for Hot Standby safety control in the Modicon Quantum automation platform, the Schneider... Read more

SKU: 140CPU67160S
Country of origin: France

      100% Original and Authentic

    Do you need a large stock? Contact us.

      100% Brand New,Ready to ship

    Do you need a large stock? Contact us.

      Support Refund,7X24h Service

    Support Refund,7X24h Service , Contact us.

      Call us: +86 135 995 07613

    Available on working days between 9:00 am to 6:00 pm

      Email us: sales2@industriaxplc.com

    Available 24/7 for inquiries and support

    Description

    Schneider Electric 140CPU67160S Unity Safety Processor

    Configured for Hot Standby safety control in the Modicon Quantum automation platform, the Schneider Electric 140CPU67160S (140CPU67160 Unity Safety Processor) provides direct physical and communication execution for redundant PLC architectures. The module integrates CPU processing, memory management, Ethernet connectivity, Modbus communication, and Hot Standby synchronization for deterministic controller operation.

    Suffix Breakdown & Model Matrix

    The supplied documentation identifies 140CPU67160S as the complete ordering reference and 140CPU67160 as the base processor model. No official suffix definition or ordering matrix is provided in the available technical data.

    Hardware Specifications

    Parameter Specification
    Model 140CPU67160S
    Brand Schneider Electric
    Product Type Unity Safety Processor
    Series Modicon Quantum Automation Platform
    Software Unity Pro XL Safety
    Processor Frequency 266 MHz
    User Memory 1024 kB Internal RAM (512 kB Data Memory)
    Backup Battery 3 VDC Lithium Battery (990XCP98000)
    Battery Capacity 1200 Ah
    Battery Service Life Up to 10 years
    Number of Local Racks 1
    Supported Rack Sizes 2, 3, 4, 6, 10, 16 slots
    Remote I/O Stations Up to 31
    Maximum Remote Discrete I/O 31,744 Inputs / 31,744 Outputs
    Maximum Remote Analog I/O 1,984 Inputs / 1,984 Outputs
    Optional Ethernet Modules Up to 6 x 140NOE77111
    Integrated Interfaces Ethernet TCP/IP, Modbus, Modbus Plus, USB
    Ethernet Connections 1 Local Ethernet TCP/IP, 1 Hot Standby Ethernet
    Modbus Connections 1 Local Modbus, 1 RS232/485 Modbus ASCII
    USB Connections 1 USB Type B
    Display LCD, 2 x 16 Characters
    Execution Time (Word) 0.09 to 0.12 us
    Execution Time (Boolean) 0.105 to 0.15 us
    Fixed-Point Arithmetic 0.96 to 1.02 us
    1 K Instruction Execution 5.03 us (65 % Boolean, 35 % Numerical); 5.14 us (100 % Boolean)
    System Overhead 1.5 ms Master Task
    Bus Current Requirement 2500 mA
    Supply Voltage 3 VDC (Lithium Battery)
    Switch Function Key Switch, Memory Port On/Off
    Local Indicators Ethernet COM LED, Ethernet ERR LED
    Electrical Connections USB Type B, Dual RJ45, 9-pin Sub-D Modbus Plus
    Certifications CE, CSA, C-Tick, TÜV Rheinland SIL3
    Power Consumption Bus Current 2500 mA

    Backplane Communication and Firmware Compatibility

    The processor exchanges controller data through the Modicon Quantum backplane while supporting Hot Standby synchronization using dedicated Ethernet communication with the 140NOE77111 module. Firmware compatibility should be maintained between redundant CPUs and associated communication modules before commissioning or processor replacement. During maintenance, processor firmware revisions should be verified to avoid synchronization mismatches within redundant controller pairs.

    Frequently Asked Questions

    Q: Can local I/O modules be used in a Hot Standby application?

    A: The supplied specifications state that local discrete and analog I/O expansion is not permitted for Hot Standby applications. Remote I/O architecture is intended for redundant operation.

    Q: Does the processor include integrated communication interfaces?

    A: Yes. The processor provides integrated Ethernet TCP/IP, Modbus, Modbus Plus, and USB interfaces. Additional Ethernet capability can be expanded with up to six 140NOE77111 communication modules.

    Q: Is processor memory retained during power removal?

    A: Internal memory retention is supported by the specified 3 VDC lithium backup battery. Battery condition should be checked during scheduled maintenance to maintain memory retention.

    Field Installation Guidelines

    • Install the processor only after confirming compatibility with the Modicon Quantum rack and power supply.
    • Verify the key switch position before downloading or modifying the application program.
    • Use shielded communication cables where specified by the installation manual, and terminate cable shields according to the site grounding standard.
    • Ensure Hot Standby processor pairs operate with matching firmware revisions before enabling redundancy.
    • Confirm adequate backplane current capacity when adding communication modules to the rack.
    • Replace the lithium backup battery only in accordance with the manufacturer's maintenance procedure to prevent unintended memory loss.

    Specifications

    • Brand: Schneider Electric

    Advantages

    • High reliability in industrial environments
    • Supports continuous operation
    • Compatible with major PLC/DCS systems