Yokogawa Electric provides advanced automation solutions for process control and safety. Its product range includes CENTUM VP DCS, ProSafe-RS safety systems, and spare parts. Yokogawa technology ensures reliable operation, long-term system support, and optimized performance across industries worldwide.

569 products

  • Sale -50% Yokogawa | ASI133-S00/SA3S0 | 8-Channel Analog Input Module Yokogawa | ASI133-S00/SA3S0 | 8-Channel Analog Input Module

    Yokogawa Yokogawa | ASI133-S00/SA3S0 | 8-Channel Analog Input Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa ASI133-S00 Analog Input Module Configured for signal acquisition in CENTUM VP I/O subsystem, the Yokogawa ASI133-S00/SA3S0j8-channel (ASI133-S00 Analog Input Module) provides direct physical/electrical execution for 4-20 mA current loop acquisition within FIO-based distributed input architecture. The module implements multi-channel analog conversion with galvanically isolated input paths and terminal-based field termination. Suffix Breakdown & Model Matrix No explicit structured suffix decomposition is defined in the provided reference data. The model designation is treated as a single ordering and configuration identifier: ASI133-S00: Base module type SA3S0j8-channel: Terminal and channel configuration reference (as provided) Hardware Specifications Parameter Specification ModelBrand Yokogawa ASI133-S00 Origin Japan (Yokogawa Electric Corporation) Weight Approx. 0.30 kg Dimensions 13.3 cm x 14.6 cm x 3.2 cm OperatingTemp Not explicitly specified in source data PowerConsumption 150 mA @ 5 VDC / 450 mA @ 24 VDC Channels 8 channel analog input Input Signal 4-20 mA DC current Isolation Channel-to-system isolated input design Terminal Block ATSA3S pressure clamp type Yokogawa DCS Analog Loop Acquisition Characteristics The ASI133-S00 operates as a field input acquisition node within Yokogawa CENTUM VP / FIO architecture, implementing 4-20 mA loop interfacing with built-in isolation per channel group. The input stage is designed for direct termination of 2-wire transmitter loops using INx.1 / INx.2 terminals with GND reference bonding. Signal conditioning supports stable current loop conversion with defined input resistance scaling under energized and de-energized states, ensuring predictable loop impedance behavior across field wiring variations. HART-capable loop compatibility enables bidirectional digital overlay communication over the 4-20 mA carrier, allowing field device diagnostics and parameter access without external multiplexing hardware. Channel isolation structure suppresses cross-channel interference during simultaneous sampling in multi-loop configurations. Frequently Asked Questions Q: Can the module support hot-swap replacement under energized backplane conditions?A: Hot-swap behavior depends on CENTUM VP subsystem configuration. Electrical isolation is maintained per channel, but backplane removal must follow system-defined maintenance sequencing. Q: Does each channel provide independent isolation?A: The module implements isolated input architecture to reduce channel interaction and protect against field-side potential differences. Q: Is external signal conditioning required for 4-20 mA loops?A: No external conversion is required. The module directly accepts 4-20 mA inputs via terminal block interface. Field Installation Guidelines Use ATSA3S terminal block with correct pressure clamp termination to ensure stable loop impedance contact. Maintain shield grounding at a single-point earth reference to avoid ground loop current injection. Separate analog input wiring from high-voltage or switching conductors to reduce induced noise coupling. Observe polarity on INx.1 (positive) and INx.2 (negative) for each channel loop. Ensure loop power budget supports transmitter compliance voltage under full-scale 20 mA conditions. Apply proper isolation testing procedures before energizing field circuits in hazardous area installations.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Safety Node Unit | Yokogawa SNB10D-425/CU2T Safety Node Unit | Yokogawa SNB10D-425/CU2T

    Yokogawa Safety Node Unit | Yokogawa SNB10D-425/CU2T

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa SNB10D-425/CU2T Safety Node Unit The Yokogawa SNB10D-425/CU2T, also cataloged as the SNB10D-425 Safety Node Unit, operates as a dedicated hardware component for transmitting analog input and contact signals to the Safety Control Unit within ProSafe-RS systems. It integrates dual-redundant power modules and ESB bus interfaces to maintain continuous data and power flow for safety I/O modules. Hardware Specifications Parameter Specification Model Brand Yokogawa Origin Japan Weight 5.9 kg (without I/O modules) Dimensions 482.6 mm (W) x 221.5 mm (H) x 205.0 mm (D) Operating Temp -20 degC to +70 degC Power Consumption 100-120 VAC: 200 VA220-240 VAC: 230 VA24 VDC: 5.5 A Power Supply Dual-redundant, AC 100-120 V / 220-240 V, 24 VDC Communication Interface ESB Bus with /CU2T Connector Unit (Part No: S9343FA) Max Safety Node Units 13 (with SEC402) / 9 (with SEC401) I/O Module Compatibility Safety-certified analog and discrete I/O modules Bus Cable Yokogawa YCB301 (≥ 1 m) Conformal Coating ISA Standard G3 Process Control Features The SNB10D-425/CU2T provides channel-to-channel isolation to prevent signal interference between analog inputs and contact signals. It supports 4-20 mA HART loop protocols for analog process instrumentation and ensures cold junction compensation (CJc) for thermocouple inputs. The ESB bus interface maintains synchronized communication with the ProSafe-RS Safety Control Unit, with galvanic isolation between power and signal paths. Frequently Asked Questions Q: What is the maximum number of SNB10D-425/CU2T units per safety control system?A: Up to 13 units with SEC402 ESB coupler modules, and up to 9 units with SEC401 modules. Q: Can I hot-swap I/O modules inside this unit?A: Modules can be replaced only under powered-down conditions to maintain SIL3 compliance; hot-swap is not supported. Q: What type of cables are required for ESB bus communication?A: Standard Yokogawa YCB301 ESB bus cables of 1 m or longer are required. Field Installation Guidelines Install inside a keyed, grounded industrial metallic cabinet to meet EMC and safety requirements. Seal unused I/O slots with SDCV01 dummy covers to prevent dust entry and thermal unevenness. Maintain correct ESB bus termination using the /CU2T connector unit; do not add external terminators. Route power and signal cables separately to reduce interference; ensure minimum bend radius and secure fastening. Ground chassis and metallic parts to the plant grounding system to prevent electrical noise propagation.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa S9361DH-00 Terminal Board Module Yokogawa S9361DH-00 Terminal Board Module

    Yokogawa Yokogawa S9361DH-00 Terminal Board Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa S9361DH-00 Terminal Board Module Configured for field signal termination and wiring distribution in CENTUM based DCS architectures, the Yokogawa S9361DH-00 (S9361DH-00 Terminal Board Module) provides direct physical and electrical execution between field termination points and system I/O interfaces. The module functions as a passive interface layer for structured routing of analog and discrete field signals, consolidating multi-core field wiring into a standardized terminal architecture used for downstream control processing modules. Suffix Breakdown & Model Matrix No validated suffix segmentation beyond the base ordering code is defined for S9361DH-00. The identifier is treated as a single fixed model designation without structured functional suffix decomposition. Hardware Specifications Parameter Specification Model S9361DH-00 Brand Yokogawa Origin Japan Weight 0.3 kg Dimensions 100 x 120 x 25 mm Operating Temp -20 degC to +70 degC Power Consumption Not specified Signal Type Analog and discrete field termination Mounting Type Panel / rack dependent system integration Interface Role Terminal board / field wiring distribution Channel-to-Channel Isolation and Field Signal Structuring The S9361DH-00 implements a passive isolation topology for structured field wiring separation, reducing electrical interaction between adjacent termination points. Channel segmentation is implemented at PCB routing and terminal block level, limiting cross-coupling between mixed analog and discrete loops. In Yokogawa DCS architectures, the termination layer supports 4-20 mA HART loop wiring aggregation, enabling consistent signal routing into I/O processing cards without altering protocol-level characteristics. Isolation barriers are implemented to maintain stable channel referencing across field ground potentials, particularly in multi-loop cabinet installations where differential grounding may occur. Frequently Asked Questions Q: Does the S9361DH-00 support hot-swap replacement under energized field wiring conditions?A: The module is a passive termination structure. Replacement under energized field wiring requires system-level isolation at the cabinet or loop level; no onboard hot-swap circuitry is implemented. Q: What is the backplane or internal current load requirement?A: The module does not actively consume backplane power. Electrical load is determined solely by connected field loops and external I/O modules. Q: Is signal integrity affected when mixing analog and discrete wiring on adjacent terminals?A: Channel separation is defined by terminal layout and PCB routing. Proper segregation of wiring groups is required to maintain isolation performance under mixed signal conditions. Field Installation Guidelines Install the module on a grounded metallic backplate with controlled torque application on all terminal screws to ensure stable contact resistance. Field wiring should be routed with physical separation between high-voltage and low-level signal pairs to minimize inductive coupling. Shield termination should be executed at a single-point ground reference within the cabinet to avoid ground loop formation. All conductors must be stripped to manufacturer-specified insertion length before clamping to prevent partial contact or micro-arcing under vibration. Cable routing bend radius should be maintained according to standard industrial control cabinet practice to avoid mechanical stress on terminal joints.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Pressure Clamp Terminal Block | Yokogawa NFTI3S-00 Pressure Clamp Terminal Block | Yokogawa NFTI3S-00

    Yokogawa Pressure Clamp Terminal Block | Yokogawa NFTI3S-00

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa NFTI3S-00 Pressure Clamp Terminal Block Configured for routing analog and pulse field signals in STARDOM FCN/FCJ I/O architectures, the Yokogawa NFTI3S-00 (NFTI3S-00 Pressure Clamp Terminal Block) provides direct physical/electrical execution between field wiring and channel-to-channel isolated I/O modules within Yokogawa STARDOM systems. Suffix Breakdown & Model Matrix NFTI3S-00: Standard configuration No further suffix segmentation defined in provided specification Optional variants may include surge/lightning protection versions (different ordering suffixes, not defined here) Hardware Specifications Parameter Specification ModelBrand Yokogawa NFTI3S-00 Origin Japan (Yokogawa Electric Corporation design origin) Weight 0.2kg Dimensions Approx. 2.2 cm x 12.4 cm x 12.6 cm OperatingTemp -20 degC to +60 degC PowerConsumption Passive device, no power consumption Signal Type Analog and pulse I/O routing Module Interface 40-pin MIL connector Field Wiring Method Spring-loaded pressure clamp terminals Supported Wire Range Approx. AWG28 to AWG14 (with ferrules) Yokogawa Channel-to-Channel Isolation Interface Characteristics The NFTI3S-00 is aligned with Yokogawa isolated I/O architectures where each channel maintains electrical separation at module level. The terminal block does not perform signal conditioning but preserves isolation integrity by maintaining controlled impedance routing from field terminals to the 40-pin MIL back interface. In STARDOM FCN/FCJ systems, this topology reduces cross-channel interference in mixed analog (4-20 mA) and pulse inputs, particularly in high-density I/O configurations such as NFAI135, NFAP135, and NFAF135 modules. The pressure clamp mechanism ensures stable contact force without periodic retightening, maintaining low contact resistance under vibration exposure. Frequently Asked Questions Q: Does NFTI3S-00 support hot-swap of connected I/O modules?A: The terminal block itself is passive and does not define hot-swap capability. Hot-swap behavior is determined by the connected STARDOM I/O module and controller backplane design. Q: Is channel-to-channel isolation affected by the terminal block wiring interface?A: No. Isolation is implemented inside the I/O module. The NFTI3S-00 only provides passive conductive routing via 40-pin MIL interface without bridging channels. Q: Can ferrule termination be used with the pressure clamp mechanism?A: Yes. Stranded conductors are typically used with ferrules to maintain stable contact force and minimize long-term loosening under vibration. Field Installation Guidelines Verify correct alignment of the 40-pin MIL connector before engagement to avoid pin deformation Use ferrule-terminated stranded wire for vibration-prone installations Maintain minimum separation between analog and pulse field cables to reduce external EMI coupling Ensure all conductors are fully seated in the pressure clamp terminal before commissioning Avoid excessive bending radius near terminal entry points to prevent mechanical stress on conductors Confirm module-side latch locking after insertion to maintain contact integrity

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa NFTB5S-00 | Pressure Clamp Terminal Block Yokogawa NFTB5S-00 | Pressure Clamp Terminal Block

    Yokogawa Yokogawa NFTB5S-00 | Pressure Clamp Terminal Block

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa NFTB5S-00 Pressure Clamp Terminal Block The Yokogawa NFTB5S-00, also cataloged as the NFTB5S-00 basic-type terminal block, operates as a dedicated hardware component for 32-channel digital I/O wiring interface within STARDOM FCN/FCJ series controllers. It provides a pressure clamp connection mechanism for high-density digital modules, enabling secure and tool-free field wire termination. HardwareSpecifications Parameter Specification ModelBrand Yokogawa NFTB5S-00 Origin Japan Channels 32 digital input channels ConnectionType Spring-loaded pressure clamp ModuleInterface 50-pin dedicated multi-pin connector RatedVoltage 24 V DC Dimensions 12.0 cm × 8.0 cm × 4.0 cm Weight 0.3 kg OperatingTemp -20 degC to +60 degC StorageTemp -40 degC to +85 degC Humidity 10%–90% RH (non-condensing) PowerConsumption Dependent on connected I/O module Process Control Connectivity The NFTB5S-00 provides channel-to-channel isolation when interfacing with Yokogawa NFDV151, NFDV157, and NFDV161 digital input modules. The design maintains signal integrity across multiple high-density inputs and supports DCS-standard 24 V DC logic levels. Its interface architecture preserves loop integrity for 4-20 mA HART and FOUNDATION Fieldbus/Profibus PA systems, preventing cross-talk between channels. Cold junction compensation (CJc) is maintained when used with compatible Yokogawa modules to ensure accurate signal conversion. Frequently Asked Questions Q: Does the NFTB5S-00 support hot-swapping of the connected digital module?A: The terminal block itself is passive; hot-swap compatibility depends on the connected NFDV module and the STARDOM system backplane. Field wires can be connected/disconnected with power off to avoid signal disruption. Q: What is the maximum wire gauge supported by the pressure clamp?A: The spring-loaded pressure clamp accommodates standard field wiring up to 2.5 mm² (14 AWG) stranded conductors without crimping. Q: Can the NFTB5S-00 be used with multiple NFDV161 64-channel modules?A: Yes, but multiple blocks must be paired according to the rack configuration. Ensure proper labeling to maintain channel-to-channel mapping integrity. Field Installation Guidelines Verify module compatibility before installation (NFDV151, NFDV157, or NFDV161). Mount the terminal block onto the module front interface, ensuring full 50-pin engagement. Connect field wiring using the pressure clamp mechanism; strip wires to recommended length (typically 8–10 mm) for secure insertion. Avoid over-tightening or bending wires; maintain straight routing to prevent stress on the clamp. Ground shielded cables to the module or enclosure according to industrial grounding standards. Maintain separation from high-voltage AC lines to prevent electromagnetic interference. Inspect connections periodically for corrosion or mechanical wear during routine maintenance.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa NFSBT02 | SB Bus T-joint Module Yokogawa NFSBT02 | SB Bus T-joint Module

    Yokogawa Yokogawa NFSBT02 | SB Bus T-joint Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa NFSBT02 SB Bus T-joint Module Configured for SB Bus line branching and physical signal distribution in the STARDOM control system, the Yokogawa NFSBT02 (NFSBT02 SB Bus T-Joint connector) provides direct physical/electrical execution for SB Bus extension topology between FCN controllers and remote I/O racks. Suffix Breakdown & Model Matrix NFSBT02 is a fixed hardware identifier for SB Bus T-joint assembly. No further factory-defined suffix segmentation is specified in provided documentation. The unit functions as a passive branching interface used with SB Bus repeat architecture. Hardware Specifications Parameter Specification ModelBrand Yokogawa NFSBT02 Origin USA Weight 0.06 kg Dimensions 11.1 x 3.2 x 2.3 cm OperatingTemp N/A PowerConsumption 5 VDC +/-5%, max 500 mA (system dependent SB Bus load) Baud Rate 128 Mbps Transmission Distance Max 8 m per line Extension Units Max 2 units Function SB Bus T-joint / branching connector Electrical Nature Passive bus interconnect module SB Bus Signal Distribution Architecture The NFSBT02 operates as a passive mechanical-electrical junction for SB Bus routing inside Yokogawa STARDOM FCN configurations. It interfaces directly with SB Bus repeat modules and maintains controlled impedance continuity across daisy-chain segments. The topology is intended for short-distance high-speed backplane extension, where signal integrity depends on correct termination placement at the final node. Within Yokogawa process automation systems, SB Bus communication infrastructure coexists with control-level protocols such as 4-20 mA HART loops and FOUNDATION Fieldbus segments, enabling layered separation between field instrumentation and controller backplane communication. While NFSBT02 itself does not process analog signals, it participates in deterministic bus segmentation supporting modular rack expansion behavior. Frequently Asked Questions Q: Can NFSBT02 be hot-swapped during system operation?A: No hot-swap behavior is defined. Physical disconnection may interrupt SB Bus continuity and cause communication loss across downstream modules. Q: Does the module require external power injection?A: No. The NFSBT02 is a passive connector. Power is only present on the SB Bus system line via connected controller or repeat modules. Q: Is termination required at the final SB Bus node?A: Yes. The last segment of the SB Bus chain requires a dedicated terminator to prevent signal reflection and communication instability. Field Installation Guidelines Ensure SB Bus cables are fully seated into the NFSBT02 connector ports before system power application. Maintain controlled cable routing to avoid excessive bending radius or mechanical stress at connector joints. The final node in any SB Bus chain must be fitted with a proper termination module to maintain impedance balance. Avoid mixed routing with unrelated communication buses to reduce coupling effects and maintain deterministic backplane behavior.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa NFSB100-S00 SB Bus Repeat Module Yokogawa NFSB100-S00 SB Bus Repeat Module

    Yokogawa Yokogawa NFSB100-S00 SB Bus Repeat Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa NFSB100-S00 SB Bus Repeat Module The Yokogawa NFSB100-S00, also cataloged as the NFSB100-S00 Bus Repeat Module, operates as a dedicated hardware component for SB Bus signal regeneration and system backplane extension within the Yokogawa STARDOM control platform. The Yokogawa NFSB100-S00 (NFSB100-S00 Bus Repeat Module) provides direct physical/electrical execution for SB Bus segment-to-segment communication continuity in FCN-based distributed control architectures. Hardware Specifications Parameter Specification Model Brand Yokogawa Origin Japan Weight 0.25 kg Dimensions 130 mm x 100 mm x 42 mm Operating Temp 0 to 55 degC Power Consumption Max 100 mA (5 VDC backplane supply) Product Type SB Bus Repeat Module Bus Interface Proprietary SB System Backplane Bus Function Signal regeneration and SB Bus segment extension Electrical Topology Dual-port backplane repeat architecture Yokogawa SB Bus Communication Architecture Characteristics The NFSB100-S00 integrates into the STARDOM FCN controller backplane architecture to extend SB Bus topology across multiple base units. The module performs signal regeneration between bus segments to maintain timing alignment and electrical waveform integrity across extended rack configurations. In Yokogawa DCS architecture, SB Bus timing is derived from deterministic backplane synchronization logic. The module operates at the physical layer, reproducing digital bus states without protocol interpretation. This enables stable propagation of controller-to-I/O communication across separated hardware frames. In process control environments using Yokogawa platforms, SB Bus systems may coexist with 4-20 mA analog loops and HART-capable field instruments, as well as FOUNDATION Fieldbus and other field-level networks, while the NFSB100-S00 remains confined to internal system backplane extension duties. Frequently Asked Questions Q: Does the NFSB100-S00 perform protocol conversion between SB Bus and field networks?A: No. The module operates only at SB Bus physical regeneration level and does not perform protocol translation or fieldbus interfacing. Q: What is the backplane load requirement of the module?A: The module draws up to 100 mA from the 5 VDC backplane supply. Power is sourced directly from the FCN base rack. Q: Can the module operate during system maintenance replacement?A: Hot-swap capability depends on system configuration and installation procedure. In standard FCN configurations, replacement requires controlled maintenance conditions to avoid SB Bus interruption. Field Installation Guidelines Installation shall be performed on the designated FCN base unit slot supporting SB Bus extension modules. Ensure the backplane connector is fully seated to maintain signal continuity across the bus segment. SB Bus cables must be routed using Yokogawa-approved connectors and kept within specified bend radius limits to prevent impedance discontinuities. Shield grounding shall be applied at single-point earth reference to minimize noise coupling between adjacent racks. Do not mix SB Bus extension wiring with power cabling or analog signal loops. Maintain physical separation to reduce electromagnetic interference across system backplane segments.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Relay Output Modules | Yokogawa NFDR541-P00 Relay Output Modules | Yokogawa NFDR541-P00

    Yokogawa Relay Output Modules | Yokogawa NFDR541-P00

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa NFDR541-P00 Relay Output Module The Yokogawa NFDR541-P00 serves as the primary NFDR541-P00 Relay Output Module utilized to execute discrete on/off field actuation across STARDOM FCN/FCJ control platforms. Configured for digital switching of external loads, the Yokogawa NFDR541-P00 provides direct electrical relay contact execution via 16 independent dry-contact output channels. SuffixBreakdown & Model Matrix Model designation NFDR541-P00 does not include formally published sub-variant segmentation within this input dataset. No additional suffix decoding is applied beyond the base ordering code -P00, which identifies the module revision level. Hardware Specifications Parameter Specification ModelBrand Yokogawa NFDR541-P00 Origin JAPAN Weight 0.3 kg Dimensions 3.3 cm x 12.7 cm x 12.7 cm OperatingTemp -10 degC to +55 degC PowerConsumption 780 mA at 5 VDC Output Channels 16 relay channels Output Type Dry contact (relay, SPST-NO) Rated Load Voltage 24 to 110 VDC, 100 to 240 VAC Max Switching Current 5 A DC per channel, 3 A AC per channel Isolation Voltage 2000 VAC channel-to-system Channel-to-System Isolation Architecture (Yokogawa DCS Interface Behavior) Within Yokogawa STARDOM I/O architecture, the NFDR541-P00 implements galvanically isolated relay stages separating field output domains from internal system logic rails. The module supports 2000 VAC dielectric strength between output groups and system backplane, reducing susceptibility to cross-channel electrical coupling during mixed AC/DC switching configurations. Relay contact segmentation ensures independent load switching per channel without shared electronic drive coupling, maintaining deterministic output state integrity under FCN/FCJ scan execution cycles. Frequently Asked Questions Q: Can the NFDR541-P00 outputs be hot-swapped under load conditions?A: The relay outputs are not intended for live load insertion or removal. External load de-energization is required prior to module extraction to avoid contact arcing and backplane transient stress. Q: What is the limitation of backplane current consumption?A: The module draws 780 mA at 5 VDC from the system power rail. Backplane supply capacity must accommodate cumulative I/O module loading within FCN/FCJ node configuration limits. Q: Does each channel operate independently in isolation?A: Each relay channel is electrically isolated at the contact stage; however, power supply and logic control originate from shared system architecture within the STARDOM node. Field Installation Guidelines The module shall be installed on DIN rail or panel mount structures with verified mechanical locking engagement. Pressure clamp terminals must be tightened according to standard industrial torque practices to ensure stable contact resistance. Field wiring for AC loads sharing a common terminal must maintain identical phase reference to prevent inter-channel short circuit conditions. For inductive DC loads, external flyback suppression components are required to limit contact voltage stress during coil de-energization events. Signal cables should be routed with separation from high-frequency or high-voltage conductors to minimize electromagnetic coupling. Shield grounding shall be performed at a single reference point to avoid ground loop formation across STARDOM I/O assemblies.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa NFAI135-S00 Analog Input Module Yokogawa NFAI135-S00 Analog Input Module

    Yokogawa Yokogawa NFAI135-S00 Analog Input Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa NFAI135 Analog Input Module Configured for 4-20 mA signal acquisition in CENTUM VP and CENTUM CS 3000 I/O subsystems, the Yokogawa NFAI135-S00 (NFAI135 Analog Input Module) provides direct electrical termination and digitization of field transmitter current loops into DCS process data via a 40-channel isolated input architecture. Suffix Breakdown & Model Matrix Model: NFAI135 Suffix: S00 S: Standard type configuration 0: Standard hardware revision 0: Basic configuration variant without additional protective or coating options Hardware Specifications Parameter Specification ModelBrand Yokogawa NFAI135-S00 Origin Yokogawa Electric Corporation Weight Approx. 0.36 kg PowerConsumption Max. 520 mA @ 5 VDC internal system power Number of Channels 40 isolated inputs Input Signal 4-20 mA DC Input Impedance 250 ohm Allowable Input Current Max. 30 mA Accuracy +/-0.1% of full scale Update Cycle 100 ms Dielectric Strength 500 VAC channel-to-channel, 1500 VAC input-to-system Channel-to-Channel Isolation Architecture The module implements per-channel electrical isolation within the CENTUM I/O node backplane interface, separating each 4-20 mA loop termination from adjacent measurement paths and system logic ground. This architecture reduces ground loop propagation paths and limits common-mode disturbance transfer during field-side transient events. Integration is aligned with Yokogawa CENTUM VP I/O node assemblies such as ANB10S and ANT10D, where isolation domains are maintained at the terminal and A/D conversion boundary. Frequently Asked Questions Q: Can the module accept voltage input directly (e.g., 1-5 VDC)?A: The documented primary configuration is 4-20 mA current input. Voltage measurement requires external conversion via precision shunt resistor unless explicitly supported by variant wiring configuration. Q: Is hot-swap supported during operation?A: Hot insertion/removal is supported only within redundant node configurations and approved I/O base assemblies. Signal disturbance may occur if removed under active single-redundant operation. Q: What is the electrical isolation boundary of the module?A: Isolation is implemented between each input channel and between input circuitry and system backplane logic, with specified withstand levels up to 1500 VAC. Field Installation Guidelines Maintain shield grounding at single-point termination on cabinet side to avoid loop currents on 4-20 mA return conductors. Ensure field wiring separation between analog input loops and high-voltage switching conductors to minimize capacitive coupling. Verify correct seating on Yokogawa I/O node base units (e.g., ANB10S / ANT10D) before energizing backplane power. Use specified Yokogawa signal cables (e.g., KS1) or equivalent shielded twisted pair conductors for loop integrity. Do not exceed rated input current of 30 mA per channel during loop testing or transmitter simulation.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Analog Output Module | SAI533-H63 | Yokogawa Analog Output Module | SAI533-H63 | Yokogawa

    Yokogawa Analog Output Module | SAI533-H63 | Yokogawa

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa SAI533-H63 Analog Output Module The Yokogawa SAI533-H63, also cataloged as the SAI533 Analog Output Module, operates as a dedicated hardware component for 4-20 mA current signal output within ProSafe-RS safety instrumented systems. It provides direct analog control and HART-based diagnostics to field devices while maintaining full channel-to-channel isolation. Hardware Specifications Parameter Specification ModelBrand Yokogawa SAI533-H63 Origin Japan Weight 0.34 kg Dimensions Standard module size for ProSafe-RS rack OperatingTemp -20 to 70 degC PowerConsumption ≤ 5 W per module typical OutputChannels 8, isolated RatedOutputRange 4-20 mA OutputRangeLimits 1.25-23 mA AllowableLoadResistance 230-600 Ω Accuracy ±48 μA DataUpdateFrequency 40 ms TemperatureDrift ±16 μA / 10 degC WithstandVoltage 1.5 kV AC between output and system for 1 min Process Control Features The module supports 4-20 mA HART loop communication, enabling simultaneous analog control and digital signal exchange. Channel-to-channel isolation minimizes interference and allows independent diagnostics on each output line. Cold junction compensation (CJc) ensures signal accuracy across the entire operating temperature range. Frequently Asked Questions Q: Can the SAI533-H63/PRP module be hot-swapped in a live ProSafe-RS rack?A: Hot-swap is not recommended; module replacement should be performed with the system in a safe state to avoid output glitches. Q: What is the maximum load resistance per channel for full-scale output?A: The allowable load resistance is 230-600 Ω per channel at 20 mA to maintain rated accuracy. Q: Is HART diagnostic data available while the module is operating in dual-redundant configuration?A: Yes, the HART protocol transmits diagnostic data independently of the redundant output channel state. Field Installation Guidelines Ensure correct keying with the prevention pin (/PRP) option to avoid incorrect module insertion. Route signal cables with minimal parallel runs near power lines to reduce electromagnetic interference. Properly ground the module shield terminals to the rack earth bus. Follow the ProSafe-RS load guidelines when operating in ambient temperatures above 60 degC to avoid derating channels. Maintain the ambient humidity below condensation levels; 5-95% RH non-condensing is recommended.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% SSC60D-F2542 Node Interface Module | Yokogawa

    Yokogawa SSC60D-F2542 Node Interface Module | Yokogawa

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa SSC60D-F2542 Node Interface Module The Yokogawa SSC60D-F2542, also cataloged as the SSC601 Node Interface Module, operates as a dedicated hardware component for field I/O communication management within CENTUM VP and ProSafe-RS systems. It executes cyclic data exchange between controllers and I/O modules, supporting redundant operation and hot-swap replacement. HardwareSpecifications Parameter Specification ModelBrand Yokogawa Origin Japan Weight 8.5kg Dimensions 482.6 mm W x 266 mm H x 399.2 mm D OperatingTemp -20 to 70 degC StorageTemp -20 to 70 degC Humidity 5-95% RH, non-condensing PowerSupply 24 V DC from FIO baseplate, dual-redundant PowerConsumption 5-8 W depending on hardware revision I/OScanCycle 1-10 ms deterministic DataRefreshRate High-speed cyclic communication Isolation Bus interface and internal circuits isolated EMCCompliance Industrial-grade noise immunity LocalIOCapacity Up to 8 safety I/O modules NodeExpansion Up to 9 nodes via SEC401, up to 13 via SEC402 with CFS1350 Process Control Features Supports 4-20 mA HART loop protocol integration for analog field instruments. Channel-to-channel isolation ensures minimal interference between adjacent I/O modules. Compatible with FOUNDATION Fieldbus and PROFIBUS PA connectivity for mixed network environments. Cold junction compensation (CJc) applied for accurate thermocouple measurements under variable ambient temperatures. Frequently Asked Questions Q: Does the SSC60D-F2542 support hot-swap replacement for I/O modules?A: Yes. Both the Node Interface Module and I/O modules on the baseplate can be replaced without shutting down the controller or field node. Q: What is the maximum I/O scan cycle achievable?A: Deterministic scan cycles range from 1 to 10 ms depending on node configuration and connected I/O modules. Q: Can firmware updates be applied without disrupting ongoing communication?A: Firmware can be upgraded while maintaining cyclic data exchange if redundant modules are installed; otherwise, temporary communication suspension occurs. Field Installation Guidelines Mount the module on a standard 19-inch rack using all specified M5 screws to maintain mechanical stability. Ensure shielded network cabling (CAT5e or higher) is properly grounded to prevent EMC issues. Maintain separation between power and communication lines to reduce crosstalk and signal degradation. Avoid obstructing the built-in fan unit to guarantee correct cooling; maintain at least 50 mm clearance above and behind the module. Observe polarity when connecting the 24 V DC power inputs; use dual-redundant supplies to support uninterrupted operation. Route ESB bus cabling according to the node topology; limit the distance between nodes as per SEC401/SEC402 specifications.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa SNB10D-445/CU2T Safety Node Unit

    Yokogawa Yokogawa SNB10D-445/CU2T Safety Node Unit

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa SNB10D-445/CU2T Safety Node Unit The Yokogawa SNB10D-445/CU2T, also cataloged as the SNB10D-445 Safety Node Unit, operates as a dedicated hardware component for high-integrity field I/O communication within ProSafe-RS Safety Instrumented Systems. It executes deterministic signal acquisition, ESB Bus data transmission, and internal power distribution to connected safety I/O modules. HardwareSpecifications Parameter Specification ModelBrand Yokogawa SNB10D-445/CU2T Origin Japan ProductType Safety Node Units Weight Approx. 5.9 kg Dimensions 120 mm (H) × 45 mm (W) × 130 mm (D) OperatingTemp −20 degC to +70 degC StorageTemp −40 degC to +85 degC RelativeHumidity 5% to 95% RH (non-condensing) PowerSupply Dual-redundant 24 VDC PowerConsumption Max 5.5 A / Approx. 8 W CommunicationInterface ESB Bus (Ethernet Safety Backbone) SafetyCompliance IEC 61508 SIL3 MountingType 19-inch rack mount / DIN rail or panel mount SupportedIOModules Up to 8 per node NetworkExpansion Up to 13 nodes (SEC402 coupler), up to 9 nodes (SEC401 coupler) Certifications CE, UL, CSA, RoHS Process Control & DCS Integration Supports 4-20 mA HART loop protocol for analog signal interfacing. Provides channel-to-channel isolation to prevent cross-coupling of analog and digital signals. Implements cold junction compensation (CJC) for thermocouple inputs, ensuring precise temperature signal interpretation. Compatible with FOUNDATION Fieldbus and Profibus PA networks for deterministic field device communication. Frequently Asked Questions Q: Does the SNB10D-445/CU2T support hot-swappable I/O modules?A: No, the unit requires a powered-down state for safe insertion or removal of I/O modules. Q: What is the maximum current load per ESB Bus segment?A: The maximum combined current consumption of connected safety nodes should not exceed the rated 5.5 A input limit per power supply path. Q: Is firmware upgrade possible without node removal?A: Firmware upgrades are supported via the ProSafe-RS configuration interface without physical removal, provided the unit is operational and in a controlled maintenance mode. Field Installation Guidelines Mount on a 19-inch rack or panel using M5 screws with insulation bushes; ensure secure grounding. Use shielded twisted-pair cables for ESB Bus connections to minimize electromagnetic interference. Terminate the last node in the bus line with the integrated /CU2T connector to prevent reflections. Maintain ambient operating temperature and humidity within specified ranges; avoid direct sunlight and corrosive exposure beyond ISA G3 tolerance. Route power and communication cables separately where possible to reduce crosstalk and maintain signal integrity.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% AVR10D-Q22020 | Yokogawa Duplexed VNet Router AVR10D-Q22020 | Yokogawa Duplexed VNet Router

    Yokogawa AVR10D-Q22020 | Yokogawa Duplexed VNet Router

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa AVR10D-Q22020 Duplexed VNet Router The Yokogawa AVR10D-Q22020, also cataloged as the AVR10D Duplexed VNet Router, operates as a dedicated hardware component for bridging Vnet/IP and legacy 10 Mbps V net networks within CENTUM VP systems. It provides direct packet forwarding and network isolation between dual-redundant communication domains. Hardware Specifications Parameter Specification ModelBrand Yokogawa AVR10D-Q22020 Origin Japan Weight Approximately 2.5 kg Dimensions 210 mm (W) x 230 mm (H) x 80 mm (D) OperatingTemp -10 degC to +55 degC OperatingHumidity 5% to 95% RH PowerConsumption Approximately 20 W PowerSupply 100-120 VAC or 220-240 VAC, 50/60 Hz, Dual Redundant Vnet/IP Interface 100 Mbps, full-duplex, RJ45 connector V net Interface 10 Mbps, BNC connector, dual-redundant or single Mounting Rack mount (19-inch), 4 x M5 screws Contact Output M4 screw terminal for system alerts Process Control Connectivity Features The AVR10D-Q22020 supports channel-to-channel isolation to prevent propagation of network noise across redundant domains. It allows deterministic routing of 100Base-TX and legacy V net traffic, with electrical isolation between Vnet/IP ports and coaxial networks. Built-in failover mechanisms in dual-redundant power and communication modules ensure uninterrupted operation during hardware faults. The unit also maintains compatibility with standard 4-20 mA HART loops and FOUNDATION Fieldbus/Profibus PA connections through connected controllers, preserving signal integrity across control layers. Frequently Asked Questions Q: VnA: Can the AVR10D-Q22020 modules be hot-swapped without network interruption?A: Yes, dual-redundant modules support bumpless hot-swap; the secondary module takes over instantaneously with sub-millisecond failover. Q: VnA: What is the maximum distance supported for Vnet/IP connections?A: Standard 100Base-TX cabling is supported up to 100 m to a Layer 2 switch; no signal repeaters are required within this range. Q: VnA: Does firmware upgrade require shutdown of V net communication?A: Firmware updates can be applied to one module while the redundant module maintains network operation, ensuring no interruption. Field Installation Guidelines Mount the router on a 19-inch rack using 4 x M5 screws. Ensure the unit is level to prevent strain on connectors. Connect power lines to dual-redundant inputs via M4 screw terminals. Verify phase and ground continuity before energizing. Attach Vnet/IP and V net coaxial cables to the respective RJ45 and BNC connectors. Ensure correct termination on coaxial lines to prevent reflections. Use separate grounding for chassis and signal shields to minimize crosstalk. Maintain at least 10 mm separation from high-power cables. Confirm all redundant modules are seated and operational via the front panel LED indicators before commissioning. Avoid bending coaxial lines below 50 mm radius; secure cables to prevent mechanical stress. Contact output terminals can be wired to local alarm panels; ensure voltage ratings are compatible.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa ASR133-S00 | RTD/POT Input Module Yokogawa ASR133-S00 | RTD/POT Input Module

    Yokogawa Yokogawa ASR133-S00 | RTD/POT Input Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa ASR133-S00 RTD/POT Input Module The Yokogawa ASR133-S00, also cataloged as the ASR133 RTD/POT Input Module, operates as a dedicated hardware component for capturing RTD and potentiometer signals within CENTUM VP and CENTUM CS 3000 systems. It provides fully isolated channel input and configurable wiring schemes for precise electrical measurement acquisition. Hardware Specifications Parameter Specification ModelBrand Yokogawa ASR133-S00 Origin Japan Weight Approx. 0.30 kg Dimensions Standard FIO module form factor OperatingTemp 0 to 55 degC (ambient) PowerConsumption 150 mA (5 VDC), 450 mA (24 VDC) InputSignal 4-20 mA, RTD (2-/3-/4-wire), POT (3-wire, 0-10 kΩ) AllowableInputCurrent 22.5 mA InputResistance (Power ON) 2-wire: 400 Ω (I=20 mA) to 750 Ω (I=4 mA)4-wire: 485 Ω (I=20 mA) to 925 Ω (I=4 mA) InputResistance (Power OFF) ≥ 1 MΩ WithstandingVoltage 1500 VAC Accuracy ±16 μA StepResponseTime 100 ms DataUpdatePeriod 10 ms TransmitterPowerSupply 16 VDC or higher, output current limit 20 mA MaximumNormalModeInputVoltage 25 V (applied to terminals by 4-wire transmitter) DriftDueToAmbientTempChange ±16 μA/10 degC ExternalConnection Pressure clamp terminal (ATSA3) HARTCommunication Supported BarrierType Isolated interface Process Control Features The module supports channel-to-channel isolation for all 8 input channels, preventing cross-talk and electrical interference in mixed-signal field environments. It provides 4-20 mA HART loop compatibility, allowing simultaneous analog measurement and digital communication. Cold junction compensation (CJC) is included for RTD inputs, ensuring temperature measurement stability under ambient variation. Frequently Asked Questions Q: VnA: Can the ASR133-S00 module be hot-swapped during operation?A: No. The module must be powered down prior to insertion or removal to maintain system integrity and avoid signal errors. Q: VnA: What is the maximum wiring resistance allowed per RTD channel?A: Each channel supports up to 50 Ω, including wiring resistance. Exceeding this may affect measurement accuracy. Q: VnA: Is firmware update required for HART communication support?A: HART communication is hardware-native. Firmware updates are not required for basic operation but may be needed for future protocol enhancements. Field Installation Guidelines Mount the module on compatible Yokogawa FIO racks using ATSA3 pressure clamp terminals. Ensure field signal shields are grounded at a single point to avoid ground loops. Maintain separation between RTD/POT signal wiring and high-voltage lines to reduce noise interference. Verify that the ambient temperature does not exceed the 0-55 degC range during installation. Check that the field wiring resistance per channel does not exceed 50 Ω, and confirm 2-/3-/4-wire configuration matches the module setup.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Access Control Module | Yokogawa ACM12 Access Control Module | Yokogawa ACM12

    Yokogawa Access Control Module | Yokogawa ACM12

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa ACM12 Access Control Module The ACM12 module, also cataloged as the ACM12 Access Control Module, operates as a dedicated hardware component for single-door access management within the EVO system. It executes user authentication, door status monitoring, and relay control for locking devices via card, PIN, or combined credentials. Hardware Specifications Parameter Specification Model Brand Yokogawa ACM12 Origin JAPAN Weight 0.25 kg (approximate enclosure only) Dimensions 14 x 9.2 x 2.5 cm Operating Temp 0 to 50 degC Power Consumption 16 VAC, 20 VA; Aux 12 VDC, 600 mA; Battery 12 VDC Gel Cell protected with 5 A fuse User Capacity 999 Door Unlock Schedules 4 schedules, 8 periods total User Schedules Capacity 32 User Security Levels 15 Door Unlock Relay Form C, 5 A / 28 VDC PGM Output 50 mA, predefined definitions Device Connections Two 4-wire Paradox readers or one 7-wire 26-bit Wiegand reader, door contact, REX, tamper Manual Unlock Negative trigger input Control Panel Compatibility EVOHD V4.5+, EVO192 V4.5+ Metal Box (optional) Minimum 20 x 25.5 x 7.6 cm Eddy-Current Probe Scaling and Signal Validation The ACM12 integrates with system-level monitoring for accurate user authentication. The module’s design allows gap voltage validation down to -10 VDC targets for connected devices, ensuring precise signal interpretation in cross-talk environments. This maintains operational integrity when paired with dual-reader setups or high-density access points. FrequentlyAskedQuestions Q: VnA: Can the ACM12 operate in offline mode?A: Yes. The ACM12 supports full offline functionality, storing the user database locally and synchronizing automatically once the panel connection is restored. Q: VnA: What is the supported reader configuration?A: The module supports two 4-wire Paradox readers (IN/OUT) or one 7-wire 26-bit Wiegand reader (IN only). Q: VnA: How does the manual unlock function work?A: The manual unlock is triggered via a negative voltage input, which momentarily engages the door relay independently of user credentials. Field Installation Guidelines Ensure all metal enclosures are properly grounded to prevent EMI interference. Connect door contacts, REX devices, and tamper switches according to standard Paradox wiring diagrams. Maintain separation of AC power lines and data wiring to reduce voltage transients and signal distortion. Mount the optional metal box to a structurally stable surface, allowing at least 2 cm clearance for airflow and cable routing. Verify fuse ratings on battery and auxiliary power connections before commissioning.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa CP703 | Field Control Station (FCS) Yokogawa CP703 | Field Control Station (FCS)

    Yokogawa Yokogawa CP703 | Field Control Station (FCS)

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa CP703 Field Control Station (FCS) The Yokogawa CP703, also cataloged as the CP701 Field Control Station, operates as a dedicated hardware component for executing control logic and managing analog/digital I/O within CENTUM CS 1000 systems. It handles data acquisition, signal processing, and real-time communication with Human Interface Stations (HIS) via VLnet. Hardware Specifications Parameter Specification Model Brand Yokogawa CP703 Core Processor R4300 Microprocessor Internal Clock 75 MHz External Clock 25 MHz Memory 16 MB DRAM Communication VLnet, RS-232C I/O Controller H8S Microcontroller with Shared RAM Redundancy Support Dual-redundant configuration (bumpless transfer) Status Indicators Front-panel LEDs Operating Temp 0 to 55 degC (standard industrial) Power Consumption 10-15 W (typical, depending on configuration) Weight 700 g Dimensions Standard FCS module form factor Origin Japan Process Control Features The CP703 supports channel-to-channel isolation to minimize cross-channel interference, ensuring accurate analog and digital signal processing. FOUNDATION Fieldbus and 4-20 mA HART loop protocols are supported for real-time process communication. Cold junction compensation (CJC) is implemented to correct thermocouple input errors across varying ambient temperatures. Frequently Asked Questions Q: Does the CP703 support hot-swapping of CPU modules?A: CPU modules are not designed for hot-swap; replacement requires a controlled shutdown or redundant module failover. Q: What is the expected switchover delay in a dual-redundant configuration?A: The failover time is near instantaneous (<100 ms) under normal operating conditions, maintaining continuous control output. Q: Can firmware upgrades be applied directly on the CP703 module?A: Firmware must be updated using Yokogawa’s supported software interface via VLnet or HIS connection; direct module flashing is not supported. Field Installation Guidelines Mount modules on standard Yokogawa FCS rack slots, ensuring proper orientation. Ensure the VLnet communication cable is shielded and grounded to reduce EMI. Maintain minimum spacing between modules to allow adequate airflow and heat dissipation. Connect power and I/O lines according to the system’s wiring diagram; verify signal grounding continuity. Follow ESD precautions when handling CPU and memory modules to prevent damage.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa DP97-B | Display Processor Card Yokogawa DP97-B | Display Processor Card

    Yokogawa Yokogawa DP97-B | Display Processor Card

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa DP97-B Display Processor Card The Yokogawa DP97-B, also cataloged as the DP97-B Display Processor Card, operates as a dedicated hardware component for real-time measurement data processing within operator station networks. It executes continuous analog and digital signal handling for monitoring thickness and coat weight profiles. Suffix Breakdown & Model Matrix This model is fixed as DP97-B. No further suffix decomposition is defined or documented. The module functions as a standalone display processor card for system integration via standard backplane edge connectors. Hardware Specifications Parameter Specification ModelBrand Yokogawa DP97-B Origin Japan Weight 0.5 kg Dimensions 96 mm (H) x 96 mm (W) x 100 mm (D) OperatingTemp 0 degC to 50 degC StorageTemp -20 degC to 70 degC Humidity 20% to 90% RH (non-condensing) PowerConsumption 100-240 VAC, 50/60 Hz Accuracy ±0.1% of span for measurement/control RedundancySupport Backup configurations supported Interface 4 x coaxial connectors (KB / R / G / B) Process Control Features The DP97-B implements channel-to-channel isolation to mitigate cross-interference within 4-20 mA HART loops and supports cold junction compensation (CJc) for thermocouple signal accuracy. It integrates directly with FOUNDATION Fieldbus and Profibus PA networks, ensuring electrical signal separation between analog input channels and display output circuits. Frequently Asked Questions Q: Does the DP97-B support hot-swap replacement in live systems?A: The module is not designed for hot-swap operation; power must be removed prior to insertion or removal to avoid signal disruption. Q: What is the typical backplane load for the DP97-B?A: The board draws power from the system backplane or designated power rail; nominal load does not exceed standard edge connector limits for 96 mm x 96 mm cards. Q: Can firmware be updated on the DP97-B?A: Firmware updates are possible only via the host operator station interface; the card does not support independent flash operations. Field Installation Guidelines Ensure module orientation matches system backplane markings to prevent misalignment of pin-type edge connectors. Connect coaxial lines (KB / R / G / B) using shielded cables with grounded shields to minimize electromagnetic interference. Avoid routing analog and digital cabling in parallel over distances exceeding 2 meters without separation or additional shielding. Verify ambient enclosure temperature remains within 0-50 degC and relative humidity stays below 90% RH. Maintain a minimum 5 mm spacing from adjacent modules to allow airflow for thermal dissipation. Confirm power supply polarity and voltage levels before initial energization; the board does not include reverse-voltage protection.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Contact Output Module | Yokogawa F3YC08-0C FA-M3 Contact Output Module | Yokogawa F3YC08-0C FA-M3

    Yokogawa Contact Output Module | Yokogawa F3YC08-0C FA-M3

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa F3YC08-0C FA-M3 Contact Output Module The Yokogawa F3YC08-0C, also cataloged as the F3YC08-0C Contact Output Module, operates as a dedicated hardware component for switching discrete field devices within the FA-M3 PLC system. Hardware Specifications Parameter Specification ModelBrand Yokogawa F3YC08-0C Origin Japan Weight 170 g Dimensions Standard FA-M3 module size OperatingTemp 0 to 55 degC PowerConsumption 75 mA typical at 5 V DC OutputType No-voltage contact, relay output NumberOfOutputs 8 points MaximumSwitchingVoltage 250 V AC, 30 V DC MaximumSwitchingCurrent 2 A per point CommonConfiguration Separate common per channel IsolationMethod Transformer isolation for each input/output ONResistance Max 200 ohm OFFResistance Min 100 kΩ InputResponseTime Configurable: 0 μs, 62.5 μs, 250 μs, 1 ms, 16 ms TerminalType 10-point M3.5 screw detachable block Channel-to-Channel Isolation Each output point is independently isolated via relay contacts, allowing simultaneous control of mixed-voltage AC and DC devices. The mechanical isolation ensures no cross-talk occurs between channels. This isolation also protects the PLC backplane from voltage transients originating in field wiring. The module design is compatible with 4-20 mA HART loop systems, maintaining signal integrity across industrial process networks. Frequently Asked Questions Q: Can the module be hot-swapped during operation?A: The detachable terminal block allows for replacement of the module without disconnecting field wiring, but only when the PLC is in a safe standby state. Energized outputs should be considered live. Q: What is the maximum simultaneous ON ratio for outputs?A: The module supports up to 100% of outputs turned on simultaneously, within thermal limits defined by Yokogawa. Q: How is the input response time configured?A: Response time can be set via the PLC CPU for 0 μs, 62.5 μs, 250 μs, 1 ms, or 16 ms. Effective ON/OFF switching delay is sampling period plus 1 ms max. Field Installation Guidelines Mount the module on the FA-M3 standard DIN rail slot. Ensure proper alignment to avoid stress on connector pins. Connect separate commons per channel as indicated to prevent unintended current paths. Route signal and power wires in separate conduits to minimize electromagnetic interference. Use M3.5 screws to secure field wiring to the detachable terminal block. Torque should comply with standard industrial wiring practices. Ground module shield and surrounding metal panel to maintain EMC compliance.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa F3XD16-3F | DC Input Module Yokogawa F3XD16-3F | DC Input Module

    Yokogawa Yokogawa F3XD16-3F | DC Input Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa F3XD16-3F DC Input Module Configured for receiving discrete DC field signals in FA-M3 controller systems, the Yokogawa F3XD16-3F (F3XD16 DC Input Module) provides direct physical/electrical execution of 24 V DC digital input acquisition from switches, sensors, and relay contacts through 16 input channels. Hardware Specifications Parameter Specification ModelBrand Yokogawa F3XD16-3F Origin Japan Weight Approx. 175 g Dimensions Standard FA-M3 module form factor OperatingTemp Not specified in supplied data PowerConsumption 65 mA at 5 V DC ProductType DC Input Module NumberOfInputs 16 InputType DC voltage (Sink/Source compatible) RatedInputVoltage 24 V DC OperatingVoltageRange 20.4 V DC to 26.4 V DC RatedInputCurrent 4.1 mA per point at 24 V DC InputImpedance Approx. 5.6 kOhm IsolationMethod Photocoupler isolation CommonConfiguration 16 points/common InputResponseOFFtoON Selectable from 62.5 us to 16 ms InputResponseONtoOFF Selectable from 62.5 us to 16 ms ExternalConnection 18-point detachable terminal block with M3.5 screws StatusIndication Individual channel LED indicators Channel-to-Channel Signal Isolation Characteristics The F3XD16-3F employs photocoupler isolation between external field circuits and the internal FA-M3 logic circuitry. Optical isolation prevents direct electrical continuity between field wiring and controller electronics while reducing susceptibility to conducted electrical noise from external devices and cable runs. The module supports both sink and source wiring configurations, allowing integration with different sensor output types without requiring separate input card variants. Input state transitions are processed using selectable filtering periods ranging from 62.5 us to 16 ms for matching field signal characteristics. Frequently Asked Questions Q: Does the F3XD16-3F support both sink and source input devices?A: Yes. The module is designed for DC voltage inputs and supports both sink and source wiring configurations. Q: What isolation technology is implemented on the input channels?A: The module uses photocoupler isolation between external input circuits and the PLC internal logic circuitry. Q: Can the input response time be adjusted for fast sensor signals?A: Yes. OFF-to-ON and ON-to-OFF response times are configurable from 62.5 us to 16 ms, allowing filtering selection according to application requirements. FieldInstallationGuidelines Verify field supply voltage remains within the specified 20.4 V DC to 26.4 V DC operating range before commissioning. Route input signal cables separately from motor power conductors, contactor wiring, and variable-frequency drive output cables. Terminate field wiring on the designated detachable terminal block and verify terminal screw tightness according to site wiring standards. Connect cable shields according to plant grounding practices and avoid multiple shield grounding points unless required by site standards. Confirm channel LED indications during startup to verify correct field device operation and input assignment. De-energize the controller rack before module installation or removal unless the platform documentation explicitly permits energized replacement procedures.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa F3XC08-0C | No-voltage Contact Input Module Yokogawa F3XC08-0C | No-voltage Contact Input Module

    Yokogawa Yokogawa F3XC08-0C | No-voltage Contact Input Module

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa F3XC08-0C No-voltage Contact Input Module The Yokogawa F3XC08-0C, also cataloged as the F3XC08-0C No-voltage Contact Input Module, operates as a dedicated hardware component for detecting and interfacing ON/OFF dry-contact signals within FA-M3 PLC platforms. Hardware Specifications Parameter Specification ModelBrand Yokogawa F3XC08-0C Origin Japan Weight 170 g Dimensions Compact module, standard FA-M3 form factor OperatingTemp 0 degC to 55 degC PowerConsumption 75 mA at 5 V DC InputType No-voltage contact (dry contact) NumberOfInputs 8 channels IsolationMethod Transformer isolation per channel InputRatings 5 V DC min., 20 mA max. ONResistance Max 200 Ω OFFResistance Min 100 kΩ MaxSimultaneousInputs 100% InputResponse Sampling time selectable: 0 μs, 62.5 μs, 250 μs, 1 ms, 16 ms (response = sampling period + 1 ms max) Connection 10-point terminal block, M3.5 screw Common Separate commons per input Interrupt Supported per input Process Control Module Features Channel-to-Channel Isolation: Each input has a dedicated common line, preventing electrical cross-talk and maintaining signal integrity in noisy environments. DCS Integration: Compatible with 4-20 mA HART loop protocol systems for direct process monitoring. Cold Junction Compensation (CJC): Maintains stable detection thresholds across ambient temperature variations. Field Signal LED Indicators: Provides instantaneous visual verification of ON/OFF input states. Frequently Asked Questions Q: Can the F3XC08-0C handle external voltage on the input terminals?A: No, the inputs are designed for dry contacts only. Applying external voltage may damage the module. Q: What is the input response time range?A: The input sampling time is selectable from 0 μs, 62.5 μs, 250 μs, 1 ms, to 16 ms. The effective response time is the sampling period plus 1 ms maximum. Q: Is hot-swapping supported for this module?A: No, the module does not support hot-swap operation. Power must be removed from the rack prior to installation or removal. Field Installation Guidelines Ensure separate commons are properly wired for each channel to maintain isolation. Route field signal wiring away from high-voltage AC or noisy switching lines to minimize interference. Use recommended copper wire cross-section (0.33–0.82 mm²) and tighten M3.5 screws to 0.8 N·m. Verify LED status indicators after wiring before applying power to the system. Maintain transformer isolation distance and avoid bridging terminals between channels.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% F3PU30-0S Power Supply Module | Yokogawa Mitsubishi Electric F3PU30-0S Power Supply Module | Yokogawa Mitsubishi Electric

    Yokogawa F3PU30-0S Power Supply Module | Yokogawa Mitsubishi Electric

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa Mitsubishi Electric F3PU30-0S Power Supply Module Configured for power conversion and backplane power distribution in Mitsubishi Electric PLC systems, the Mitsubishi Electric F3PU30-0S (F3PU30 Power Supply Module) provides direct electrical execution. The module accepts a single-phase AC input and delivers regulated 5 V DC output for system operation. It supports operation under specified input voltage fluctuation conditions and incorporates insulation and dielectric withstand characteristics for industrial control environments. Hardware Specifications Parameter Specification Model F3PU30-0S Brand Mitsubishi Electric Product Type Power Supply Module Origin Not specified in supplied data Rated Input Voltage 100 - 240 V AC, single-phase, 50/60 Hz Input Voltage Range 85 - 264 V AC, 50/60 Hz +/- 3 Hz Power Consumption 100 VA Inrush Current 20 A max. at 120 V AC (Ta = 25 degC); 45 A max. at 240 V AC (Ta = 25 degC) Rated Output Voltage 5 V DC Rated Output Current 2.0 A / 4.3 A / 6.0 A Insulation Resistance 5 Mohm min. at 500 V DC between AC terminals and FG; 5 Mohm min. at 500 V DC between FAIL contact group and internal circuit Dielectric Strength 1500 V AC for 1 minute between AC terminals and FG Allowable Momentary Power Failure 20 ms (Standard Mode); 10 ms (Immediate Detection Mode) Noise Immunity 1500 Vp-p, 1 us pulse width, 1 ns rise time, 25 - 60 Hz repetition frequency Dimensions 58 mm (W) x 100 mm (H) x 126.1 mm (D) Weight 380 g Operating Temp Not specified in supplied data Backplane Power Distribution and Firmware Compatibility The F3PU30-0S functions as the power source for associated PLC hardware through the system backplane. Correct installation requires verification that the aggregate current consumption of connected modules remains within the available output capacity. Firmware compatibility is determined by the host PLC platform and associated system modules; no firmware-specific restrictions are stated in the supplied specification. Frequently Asked Questions Q: Does the F3PU30-0S provide isolation between the AC input and protective ground?A: Yes. The module specifies an insulation resistance of 5 Mohm or greater at 500 V DC and a dielectric withstand voltage of 1500 V AC for 1 minute between external AC terminals and the FG terminal. Q: What occurs during a short-duration power interruption?A: The module specifies an allowable momentary power failure time of 20 ms in Standard Mode and 10 ms in Immediate Detection Mode. Q: What output voltage is supplied by the module?A: The rated output voltage is 5 V DC. The specification lists output current ratings of 2.0 A, 4.3 A, and 6.0 A depending on the configured system requirements. Field Installation Guidelines Mount the module according to the mechanical orientation specified by the host PLC rack or base unit. Verify that incoming power wiring matches the specified 100 - 240 V AC single-phase supply requirements. Connect protective earth (FG) using a low-impedance grounding conductor in accordance with site electrical standards. Separate AC input wiring from signal and communication cables to minimize conducted and radiated noise coupling. Confirm that total downstream module current demand does not exceed the available 5 V DC output capacity. Inspect terminal tightness and grounding continuity before energizing the system. Maintain adequate enclosure ventilation to support thermal dissipation during continuous operation.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa Fiber-optic FA-bus Module F3LR01-ON Yokogawa Fiber-optic FA-bus Module F3LR01-ON

    Yokogawa Yokogawa Fiber-optic FA-bus Module F3LR01-ON

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa Fiber-optic FA-bus Module F3LR01-ON The Fiber-optic FA-bus Module F3LR01-ON, also cataloged as the F3LR01-ON FA-bus Module, operates as a dedicated hardware component for configuring distributed control over a fiber-optic FA bus network. It allows direct physical interfacing of remote I/O modules connected via fiber-optic cabling, enabling subunit modules to be addressed identically to those in the main unit. Hardware Specifications Parameter Specification ModelBrand F3LR01-ON Origin Industrial Grade Weight 100 g Dimensions 28.9 W × 100 H × 83.2 D mm OperatingTemp 0 to 55 degC StorageTemp -20 to 75 degC HumidityRange 10 to 90% RH (non-condensing) PowerConsumption 220 mA @ 5 VDC ModuleType Fiber-optic FA-bus Interface Backplane Communication and Deterministic Network Features The module supports high-speed backplane bus communication, enabling deterministic data exchange between main and subunits. Firmware flash compatibility ensures that network updates or module replacements can occur without disrupting system operation. The module’s internal bus architecture manages signal timing and density scaling for consistent I/O sampling across connected subunits. Frequently Asked Questions Q: Can this module support hot-swapping?A: The module is not rated for hot-swap operation. All connections must be powered down before insertion or removal to prevent signal corruption. Q: What is the maximum cable length for reliable fiber-optic FA-bus communication?A: Length is dictated by standard industrial fiber-optic transmission limits and attenuation; system design should comply with fiber specifications to maintain signal integrity. Q: Are firmware updates backward compatible?A: Firmware updates maintain backward compatibility with previously installed modules, provided the overall system firmware version supports the F3LR01-ON protocol set. Field Installation Guidelines Mount modules securely within FA-M3 main and subunits following DIN-rail specifications. Ensure fiber-optic connectors are fully seated and protected from sharp bends or mechanical stress. Maintain grounding for shielded fiber-optic cables to prevent EMI interference. Avoid routing fiber-optic lines near high-voltage switching components. Verify all modules are powered down before installation or removal.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Ethernet Interface Module | Yokogawa F3LE12-0T Ethernet Interface Module | Yokogawa F3LE12-0T

    Yokogawa Ethernet Interface Module | Yokogawa F3LE12-0T

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa F3LE12-0T Ethernet Interface Module Configured for Ethernet data communication in IEEE 802.3 networks, the Yokogawa F3LE12-0T (F3LE12 Ethernet Interface Module) provides direct physical and protocol-level connectivity between controller nodes, personal computers, and workstations using TCP/IP or UDP/IP communication services. Suffix Breakdown & Model Matrix The supplied documentation identifies a single catalog model: Parameter Specification Full Model F3LE12-0T Base Model F3LE12 Module Type Ethernet Interface Module Network Standards 100BASE-TX, 10BASE-T No additional suffix decoding or option matrix is specified in the provided documentation. Hardware Specifications Parameter Specification Model F3LE12-0T Brand Yokogawa Origin JAPAN Product Type Ethernet Interface Module Supported Networks IEEE 802.3 compliant Ethernet Ethernet Standards 100BASE-TX, 10BASE-T Access Method CSMA/CD Transmission Speed 100 Mbps (100BASE-TX), 10 Mbps (10BASE-T) Transmission Method Base band Maximum Distance Between Nodes 100 m Largest Connection Configuration 2 cascade segments (100BASE-TX), 4 cascade segments (10BASE-T) Supported Protocols TCP, UDP, IP, ICMP, ARP Maximum Installed Modules Up to 6 modules depending on CPU model Internal Current Consumption 500 mA Dimensions 28.98 mm (W) x 100 mm (H) x 83.2 mm (D) Weight 130 g Channel-to-Channel Network Communication Characteristics The F3LE12-0T module is designed for Ethernet-based controller communication within Yokogawa control platforms. Network access is performed through the CSMA/CD method and supports both 100BASE-TX and 10BASE-T physical layers. The module supports TCP, UDP, IP, ICMP, and ARP protocol stacks for data exchange between networked automation devices and supervisory systems. Communication is established through standard IEEE 802.3 Ethernet infrastructure with a maximum node separation distance of 100 m per segment. Frequently Asked Questions Q: Does the F3LE12-0T require an external power supply?A: No. The supplied specification indicates no external power supply requirement. The module draws 500 mA internal current from the host system. Q: Which Ethernet standards are supported by the module?A: The module supports IEEE 802.3 compliant 100BASE-TX and 10BASE-T Ethernet networks using baseband transmission. Q: What communication protocols are available through the module?A: Supported protocols include TCP, UDP, IP, ICMP, and ARP. Field Installation Guidelines Verify module compatibility with the target Yokogawa CPU before installation. Install the module with system power removed unless the host platform documentation explicitly permits online replacement. Use IEEE 802.3 compliant Ethernet cabling appropriate for the selected network speed. Maintain cable separation from high-voltage and high-current conductors to reduce electromagnetic interference. Terminate cable shields according to the site grounding standard and avoid multiple uncontrolled shield grounding points. Confirm network addressing and protocol configuration before connecting the module to an active control network. After installation, verify link status and network communication with connected nodes before commissioning.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     

  • Sale -50% Yokogawa Temperature Monitoring Module | F3CX04-0N Yokogawa Temperature Monitoring Module | F3CX04-0N

    Yokogawa Yokogawa Temperature Monitoring Module | F3CX04-0N

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

    Yokogawa F3CX04-0N Temperature Monitoring Module The Yokogawa F3CX04-0N, also cataloged as the F3CX04 Temperature Monitoring Module, operates as a dedicated hardware component for multi-channel temperature input processing within FA-M3 automation platforms. HardwareSpecifications Parameter Specification Model Brand Yokogawa  F3CX04-0N Origin Japan Weight 200 g Dimensions 28.9 W × 100 H × 106.1 D mm OperatingTemp Max allowable ambient temperature change rate: 10 degC/h PowerConsumption 440 mA at 5 VDC NumberOfChannels 4 InputIsolation Isolated via photocouplers and transformers TerminalVoltageWithstand 150 VAC tested AlarmTypes Input upper limit alarm, input lower limit alarm (with or without delay) NumberOfAlarmOutputs 4 points per channel (only alarms 1 and 2 have relays) AlarmDelayTimer Yes WarmUpTime 30 minutes min MountingPosition Horizontal only; inverted orientation not allowed ExternalConnection 18-point terminal block with M3.5 screws InputProcessingModes Single-input (default), Two-input changeover Industrial Control Features Omron modules integrate deterministic backplane bus communication for FA-M3 systems. Firmware flash compatibility allows in-field updates without disrupting ongoing input monitoring. Channel-to-channel isolation is maintained to prevent cross-interference, supporting precise analog signal acquisition across all four inputs. Single- and two-input changeover modes allow paired or independent channel monitoring, with configurable alarm delay timers to align with system response requirements. Frequently Asked Questions Q: Can the F3CX04-0N be hot-swapped while the FA-M3 base module is powered?A: No. The module requires system power-down before insertion or removal to prevent signal disruption and relay misoperation. Q: What is the maximum rate of ambient temperature change the module can tolerate?A: The module supports up to 10 degC per hour. Faster changes may affect input accuracy and alarm triggering. Q: Are firmware updates compatible with all installed channel configurations?A: Yes, firmware flash operations preserve current input processing settings, but it is recommended to verify alarm and relay settings post-update. Field Installation Guidelines Mount the module horizontally on the FA-M3 base; inverted or vertical mounting is not permitted. Ensure 18-point terminal block connections are tightened with M3.5 screws to maintain proper electrical isolation. Route analog input wiring separately from high-current or switching circuits to minimize cross-talk. Verify ambient temperature stability; avoid locations with rapid thermal fluctuations exceeding 10 degC per hour. Ground module shielding appropriately to reduce electromagnetic interference and maintain signal integrity.

    18 in stock Delivery within 48 hours, pay afterwards  Mid weeks
    Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

    Weekends
    We offer no deliveries in the weekends.

    International
    Depending on where you’re located, we offer next day delivery. Check your status on this link

     


You have seen 144 out of 569 products

Login

Forgot your password?

Don't have an account yet?
Create account