Emerson provides advanced automation solutions for process control and industrial operations. Its product range includes DeltaV distributed control systems, Ovation control solutions, and EPRO modules. Emerson products ensure reliable operation, optimized performance, and long-term support for industrial automation worldwide.
Emerson
-
EMERSON Emerson KJ3007X1-EA1 12P3275X012 LocalBus Right Extender for DeltaV
Product Description Overview The Emerson KJ3007X1-EA1 (12P3275X012) serves as a LocalBus Right Extender for the DeltaV™ M-Series Distributed Control System (DCS). Installed at the rightmost slot of an M-Series carrier, it provides a secure connection for LocalBus expansion cables, ensuring consistent 12.6 VDC logic power and reliable communication across extended I/O segments. This module is essential for scaling DeltaV systems horizontally while maintaining electrical integrity and system reliability. Key Features High-Speed Data ContinuityMaintains low-latency communication across multiple carrier assemblies, ensuring seamless integration with controllers and I/O modules on secondary rails. High-Current Power SupportDelivers up to 8 A at 12.6 VDC to downstream I/O devices, preventing voltage drop across extended LocalBus segments. Cold-Swap SafetyNot hot-swappable; the system must be powered down before installation or removal to avoid data corruption or electrical hazards. Secure Mechanical DesignFeatures a robust locking mechanism to secure the LocalBus expansion cable against vibration, shock, and movement in industrial environments. Industrial-Grade Environmental Protection Operating temperature: -40°C to +70°C Conformal coating: G3-level protection against moisture, salt, and corrosive gases Shock and vibration rated for harsh environments Fully certified for hazardous locations: Class 1 Div 2, ATEX Zone 2 Technical Specifications Feature Specification Model Number KJ3007X1-EA1 Part Number 12P3275X012 Voltage Rating 12.6 VDC LocalBus Current Rating 8 A Maximum Mounting Right-hand slot, DeltaV M-Series Carrier Input Power 5 VDC @ 100 mA (for internal electronics) Environmental Rating -40°C to +70°C, ISA-S71.04 Class G3 Shock & Vibration 10 g half-sine 11 ms, 1 mm P-P 2–13.2 Hz, 0.7 g 13.2–150 Hz Relative Humidity 5–95% non-condensing Compliance CE, UL, FM, ATEX Zone 2 Applications Designed for M-Series I/O expansions requiring reliable LocalBus bridging. Ideal for multi-carrier DeltaV installations where consistent logic power and uninterrupted communication are critical. FAQ Q: Can this module be installed while the system is powered?A: No, it requires the system to be powered down to prevent data or electrical issues. Q: Does it require calibration or user maintenance?A: No calibration is needed, and it contains no user-serviceable components. Q: How does it compare to similar DeltaV right extenders?A: The KJ3007X1-EA1 supports higher current loads (up to 8 A) and wider environmental ranges than earlier versions, ensuring stable operation for larger I/O configurations. Q: What protections are built in for industrial environments?A: It features G3 conformal coating, vibration and shock resistance, and hazardous location certifications (Class 1 Div 2, ATEX Zone 2).
$200.00 $100.00
-
EMERSON Emerson KJ1501X1-BC2 12P2045X012 System Power Supply for DeltaV
Product Description Overview The Emerson KJ1501X1-BC2 (12P2045X012) is a high-performance system power supply designed for the DeltaV™ M-Series Distributed Control System (DCS). This module converts 24 VDC bulk power into regulated 12 VDC output to supply the LocalBus, ensuring reliable operation of controllers and I/O modules in demanding industrial environments. Its compact, rail-mounted design supports both standalone and redundant configurations for high system availability. Key Features High-Efficiency Power ConversionThe BC2 model delivers superior energy efficiency, minimizing heat generation and enhancing reliability in dense cabinet installations. Redundant Load SharingSupports parallel operation with active load balancing. A redundant module instantly assumes full output in case of failure, guaranteeing uninterrupted system operation. Advanced Protection CircuitryIncludes overvoltage protection, current limiting, and reverse polarity safeguards to protect both the module and connected DeltaV components. Visual DiagnosticsEquipped with a front-panel Power OK LED to indicate correct 12 VDC output. LED off signals input loss or internal fault. Environmental ResilienceRated for harsh plant conditions with an operating range of -40°C to +70°C and G3-level protection against moisture, salt, and corrosive atmospheres. Technical Specifications Feature Specification Model Number KJ1501X1-BC2 Part Number 12P2045X012 Input Voltage 24 VDC Nominal Output Voltage 12.2 VDC Regulated LocalBus Power Output Current 13 A Max per module Output Power Up to 156 W for 12 VDC load Mounting DeltaV M-Series Controller/I/O Carrier Protection Features Overvoltage, Current Limit, Reverse Polarity Environmental Ratings -40°C to +70°C, Conformal Coating (G3) Certifications ATEX, CE, UL, FM Class 1 Div 2, CSA Weight 0.7 kg Applications Ideal for M-Series controller carriers and I/O systems where high current capacity, thermal efficiency, and redundancy are required. Supports high-density configurations with multiple MQ controllers or advanced I/O modules. FAQ Q: Can two KJ1501X1-BC2 modules operate redundantly?A: Yes, they support active load sharing for seamless redundancy. Q: What happens if input polarity is reversed?A: The module’s built-in reverse polarity protection prevents damage. Q: Is this module compatible with older BA-series carriers?A: It is optimized for M-Series carriers; BA-series compatibility is limited and not recommended for high-current loads. Q: What is the expected service life under continuous operation?A: With proper cooling, the module typically exceeds 10 years of service in standard industrial conditions.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-NB1 | 12P3368X012 | Dual Left-Side LocalBus Extender
Product Description Overview The Emerson KJ4001X1-NB1 (12P3368X012) is a specialized 1-wide Dual Left-Side LocalBus Extender designed for the DeltaV™ M-series Distributed Control System (DCS). It enables seamless extension of the LocalBus backplane to the left side of controller or I/O carriers, supporting additional modules while maintaining reliable communication and power integrity across multiple carriers. This module is critical for engineers who need to expand DeltaV installations without compromising signal stability or system redundancy. Key Features High-Current LocalBus CapabilitySupports the full LocalBus load at 12.6 VDC, 8 A, ensuring sufficient power for downstream I/O modules. Redundant Communication PathsDual-path design preserves signal integrity across multiple carriers, maintaining high-speed data transfer between controllers and I/O devices. Cold-Swap Safety DesignCannot be inserted or removed while the system is energized, preventing LocalBus interruption or short circuits. Environmental Resilience Operating Temperature: -40°C to +70°C G3 Conformal Coating for protection against corrosive gases and airborne contaminants Shock Resistance: 10 g, 11 ms half-sine wave Vibration Resistance: 1 mm peak-to-peak (2–13.2 Hz) and 0.7 g (13.2–150 Hz) Flexible Cabinet LayoutAllows bridging of LocalBus signals between DIN rails or carriers, enabling optimized use of cabinet space while adhering to a maximum total interconnection length of 6.5 meters. Hazardous Area CertificationSuitable for Zone 2, ATEX II 3G, FM Class I Div 2 environments, providing compliance for industrial safety requirements. Technical Specifications Feature Specification Model Number KJ4001X1-NB1 Part Number 12P3368X012 LocalBus Voltage 12.6 VDC Maximum Current 8 A Form Factor 1-Wide Carrier Module Operating Temperature -40°C to +70°C Relative Humidity 5% to 95%, Non-condensing Vibration 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Shock 10 g, 11 ms half-sine Conformal Coating ISA-S71.04-1985 Class G3 Hazardous Area Certification ATEX II 3G, FM Class I Div 2, Zone 2 Usage Guidelines Always ensure the combined length of I/O carriers and LocalBus extenders does not exceed 6.5 meters to prevent signal degradation or voltage drops. Power must be de-energized before installation or removal, and interconnecting cables should be routed through conduit for safety and compliance. Applications Ideal for expanding DeltaV M-series systems where additional I/O carriers or controllers are required on the left side of a cabinet or DIN rail. Provides stable power and reliable high-speed communication for chemical, oil & gas, and manufacturing process control applications. FAQ Q: Can the KJ4001X1-NB1 be hot-swapped?A: No, this module must be installed or removed only when system power is off. Q: What is the maximum LocalBus extension length?A: The total length of interconnected carriers and LocalBus extenders should not exceed 6.5 meters. Q: Is this module suitable for hazardous environments?A: Yes, it is certified for ATEX Zone 2, FM Class I Div 2, and other hazardous area standards. Q: Can it be used on the right side of a carrier stack?A: No, the KJ4001X1-NB1 is specifically designed for left-side LocalBus extension.
$200.00 $100.00
-
EMERSON Emerson KJ1501X1-BA1 | 12P0550X022 | Dual-Channel Redundant Power Supply
Product Description Overview The Emerson KJ1501X1-BA1 (12P0550X022) is a dual-channel redundant power supply module designed for the DeltaV™ M-Series Distributed Control System (DCS). It provides regulated logic power to controllers, I/O modules, and workstation interfaces, ensuring continuous system operation in critical industrial environments. This modular, rail-mounted power supply supports hot-swappable operation and parallel installation for redundancy. Its compact design simplifies integration while delivering reliable performance under varying electrical and environmental conditions. Key Features Dual-Channel RedundancyTwo independent channels allow parallel operation. If one channel fails, the second maintains full output without interruption, supporting zero-downtime control. Hot-Swappable DesignModules can be replaced or serviced while the system remains online, avoiding operational interruptions. Wide Input Voltage RangeAccepts 85–264 VAC, accommodating global power standards. High EfficiencyOptimized for low power loss and reduced heat generation, supporting efficient cabinet operation. Industrial Hardening Operating Temperature: 0°C to 60°C Storage Temperature: -40°C to 85°C Humidity: 5–95% non-condensing Vibration: 0.5 g RMS, 10–500 Hz Shock: 15 g, 11 ms half-sine Conformal Coating: G3 protection for moisture, dust, and corrosive gases EMI/RFI Shielding for electrically noisy environments Integrated DiagnosticsFront-panel LEDs indicate power status and faults, allowing immediate visual monitoring of module health. Technical Specifications Feature Specification Model Number KJ1501X1-BA1 Part Number 12P0550X022 Input Voltage 85–264 VAC Input Current 10 A maximum Output Voltage 24 VDC regulated logic power Output Current 40 A maximum Power Dissipation 240 W maximum Mounting DeltaV M-Series Carrier Operating Temperature 0°C to 60°C Storage Temperature -40°C to 85°C Humidity 5% to 95% non-condensing Vibration Resistance 0.5 g RMS, 10–500 Hz Shock Resistance 15 g, 11 ms half-sine MTBF >250,000 hours Certifications ATEX, CE, UL, FM Class 1 Div 2 Applications Ideal for providing logic power to DeltaV controllers and I/O modules, the KJ1501X1-BA1 ensures stable local bus operation in chemical, oil & gas, and manufacturing control systems. It is designed for redundant configurations in mission-critical systems. FAQ Q: Can the KJ1501X1-BA1 be installed alongside another module for redundancy?A: Yes, two modules can be operated in parallel for full redundancy and bumpless load transfer. Q: Is this power supply suitable for field devices?A: No, it is intended only for system logic power. Field devices require dedicated high-current power modules. Q: What happens if the module fails while online?A: The second redundant channel immediately assumes full load, maintaining uninterrupted system operation. Q: Can this unit operate in harsh industrial environments?A: Yes, it is rated for temperature extremes, humidity, vibration, and includes conformal coating and EMI/RFI protection.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-BA3 | 12P0547X092 | High-Side 8-Channel RTU
Product Description Overview The Emerson KJ4001X1-BA3 (12P0547X092) is an 8-channel, 24 VDC high-side remote termination unit (RTU) engineered for seamless integration with Emerson’s DeltaV™ Distributed Control System. It provides a secure interface between digital output modules and field devices, ensuring reliable signal transmission and protection in complex industrial environments. Designed for robust industrial use, the KJ4001X1-BA3 incorporates individual channel fusing, integrated diagnostic LEDs, and high-side switching for enhanced operational safety. Its compact footprint and modular design allow easy installation on DeltaV M-series and S-series carriers. Key Features Advanced Channel ProtectionEach of the 8 channels has dedicated fusing, isolating faults to the affected output and preventing disruption to the remaining circuits. High-Side Switching ArchitectureControls the positive power supply line to field devices, reducing the risk of accidental energization and improving safety in grounded fault conditions. Visual DiagnosticsEquipped with channel status indicators and blown-fuse LEDs, enabling quick identification of failures without specialized test equipment. Durable Industrial Design Operating Temperature: -40°C to +70°C G3 Conformal Coating for resistance against humidity, salt air, and corrosive gases Vibration Resistance: 1 mm peak-to-peak (5–16 Hz) and 0.5 G (16–150 Hz) Shock Resistance: 10 G, 11 ms sinewave Simplified InstallationPre-wired mass-termination cable connects to DeltaV I/O modules, minimizing wiring errors and reducing commissioning time. Technical Specifications Feature Specification Model Number KJ4001X1-BA3 Part Number 12P0547X092 Channel Count 8 independent channels Nominal Voltage 24 VDC Maximum Current 8 A per channel Maximum Operating Voltage 30 VDC Switching Type High-Side (Source) Fusing Individual per channel Indicators Channel status LEDs, blown-fuse LEDs Mounting DeltaV M-series or S-series carrier Temperature Range -40°C to +70°C Conformal Coating G3 (ISA-S71.04-1985) Vibration Resistance 1 mm (5–16 Hz), 0.5 G (16–150 Hz) Shock Resistance 10 G, 11 ms sinewave Weight 0.2 kg Dimensions 13.0 cm × 1.9 cm × 19.1 cm Hazardous Area Rating ATEX, UL, FM Class 1 Div 2 Status Discontinued by manufacturer Applications Ideal for controlling solenoids, relays, and other field actuators in process automation, the KJ4001X1-BA3 supports safe and isolated switching in chemical, oil and gas, and manufacturing environments. FAQ Q: Is the KJ4001X1-BA3 compatible with older DeltaV modules?A: Yes, it maintains backward compatibility with most DeltaV systems, provided the field device current does not exceed fuse ratings. Q: Can the unit handle continuous 8 A per channel?A: Yes, but it should not exceed the rated maximum operating voltage of 30 VDC. Q: What happens if one channel shorts?A: The affected channel’s fuse will blow, isolating the fault while the remaining channels continue operation. Q: Can this unit be used in hazardous areas?A: Yes, it is rated for ATEX, UL, and FM Class 1 Div 2 environments.
$200.00 $100.00
-
EMERSON Emerson KJ2005X1-MQ1 12P3273X012 M-Series DeltaV Controller Module
Overview The Emerson KJ2005X1-MQ1 (12P3273X012) is a high-performance M-series MQ Controller designed for the DeltaV™ Distributed Control System. It functions as the central processing unit for M-series I/O subsystems, executing control logic, coordinating data, and managing communication with field devices. The MQ revision delivers improved processing speed, larger memory capacity, and robust redundancy features, making it ideal for modern process automation applications. Key Features High-Speed ProcessingOptimized for demanding control loops, the MQ controller executes logic and I/O handling faster than legacy M3 and M5 controllers, supporting high-speed process control. Expanded Memory CapacityHandles complex configurations and up to 750 signals per controller. Supports extended event logging and history buffering for temporary network interruptions. Redundant ArchitectureSupports 1:1 hot-standby redundancy. When paired with a second MQ controller, the system maintains continuous operation with seamless failover. Industrial Durability Operating Temperature: –40°C to +70°C G3 Conformal Coating for moisture, dust, and chemical resistance Engineered for shock and vibration tolerance, suitable for installation near heavy machinery Flexible CommunicationDual redundant 10/100 Mbps Ethernet ports with auto-sensing capabilities ensure reliable connectivity to the DeltaV Control Network. RoHS ComplianceDesigned in accordance with GB/T 26572 standards for hazardous substances. EFUP (Environmentally Friendly Use Period) is valid under normal operating conditions defined in the product manual. Technical Specifications Feature Specification Model Number KJ2005X1-MQ1 Part Number 12P3273X012 Input Power 24 VDC at 250 mA (Nominal) Internal Fuse 3.0 A (Non-replaceable) Network Redundant Ethernet A/B, Auto-Sensing Maximum Local I/O Modules Up to 64 Certifications ATEX, CE, UL, FM Class 1 Div 2 Operating Temperature –40°C to +70°C Environmental Protection G3 Conformal Coating, Shock and Vibration Resistant Redundancy 1:1 Hot-Standby Support Applications Ideal for process automation in chemical, oil & gas, and manufacturing industries. The MQ controller is suitable for new M-series installations or upgrading legacy systems, providing the computational headroom required for advanced control strategies and real-time data handling. FAQ Can the controller be replaced while the system is active?No. Power must be turned off before removal or installation. Does this unit require calibration?No calibration is needed, and there are no user-serviceable parts. How many I/O signals can the MQ controller manage?Up to 750 signals per controller, depending on configuration. Is this product compliant with China RoHS standards?Yes. Critical components meet GB/T 26572 limits, with EFUP valid under specified operating conditions. What type of redundancy is supported?1:1 hot-standby redundancy allows seamless failover with a mirrored secondary controller.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-CB1 12P0683X082 High-Side 8-Channel RTU Module
Overview The Emerson KJ4001X1-CB1 (12P0683X082) is a high-performance 8-channel 24 VDC high-side Remote Termination Unit (RTU) designed for integration with DeltaV™ M-series and S-series Distributed Control Systems. It functions as a reliable interface between digital output cards and field devices such as solenoids, relays, and indicator lights, simplifying wiring with a mass-termination connection to the I/O module. This module emphasizes operational reliability and maintenance efficiency, featuring individually fused channels, high-side switching architecture, and visual diagnostic indicators to minimize downtime. Key Features High-Side Switching ArchitectureEnsures each load is referenced to ground when inactive, enhancing safety and preventing accidental activation during faults. Per-Channel FusingEach of the 8 outputs includes individual fuses, isolating faults without affecting other channels. Visual DiagnosticsLED indicators show channel status, and fuse indicators provide immediate identification of blown fuses. Modular InstallationPlug-and-play design allows the termination unit to be replaced without disturbing complex I/O carrier wiring. Industrial-Grade ResilienceDesigned for harsh environments with conformal coating protection against moisture and chemicals, operating between –40°C to +70°C. CompatibilityOptimized for DeltaV M-series and S-series carriers, compatible with digital output cards requiring high-side switching. Technical Specifications Feature Specification Model Number KJ4001X1-CB1 Part Number 12P0683X082 Channels 8 Nominal Voltage 24 VDC Maximum Current 1.0 A per channel Input Power 250 VAC / 60 VDC, 1 A per channel Mounting DeltaV M-series / S-series carrier Environmental Rating -40°C to +70°C, Shock 10 g / 11 ms, Vibration 1 mm peak / 0.7 g 2–150 Hz Airborne Contaminant Resistance ISA-S71.04 Class G3 Hazardous Area Certification ATEX, UL, FM Class 1 Div 2 Applications Ideal for oil & gas, chemical, and industrial process automation, the KJ4001X1-CB1 is suitable for solenoid actuation, relay control, and indicator monitoring where high reliability and clear diagnostics are essential. Comparison with BA2 Series While similar to the BA2 series, the CB1 integrates updated internal components and specific fuse ratings tailored to newer DeltaV digital output cards. Engineers should verify field device load requirements against fuse ratings before replacement. FAQ Can this unit be replaced while the system is powered?No, it must only be installed or removed when system power is off. Does this module require calibration?No calibration is necessary, and the unit contains no user-serviceable parts. What is the maximum current per channel?Each channel supports up to 1.0 A, depending on the fuse installed.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-BA2 12P0547X082 DeltaV 8-Channel Power Termination
Product Description Emerson KJ4001X1-BA2 (12P0547X082) is an 8-channel high-side termination block designed for DeltaV M-series and S-series I/O systems. This module provides reliable 24 VDC power distribution and fused protection for field devices, ensuring safety, high availability, and simplified maintenance in industrial automation environments. ApplicationsThe KJ4001X1-BA2 is ideal for safely powering actuators, solenoids, relays, and other field devices from DeltaV controllers. Its modular and high-density design makes it suitable for process control cabinets in chemical, oil & gas, and manufacturing facilities. Key Features 8 fused channels with high-side switching for individual circuit protection Compact, high-density form factor minimizes cabinet footprint Screw-terminal field connections and ribbon/D-shell connections to I/O cards Visual indicators for fuse status enable rapid troubleshooting Conformal coating and industrial-grade construction for harsh environments IP20 rated with Class 1 Div. 2 hazardous location certification Performance Characteristics Robust Protection: Prevents a fault in one channel from affecting the rest of the system. High-Density Termination: Simplifies field wiring with mass termination cables. Industrial Reliability: Rated for -40°C to +70°C, vibration and shock resistant, G3 airborne contaminant protection. Maintenance Efficiency: Hot-swappable design allows replacement without rewiring individual leads. Technical Specifications Feature Specification Model KJ4001X1-BA2 (12P0547X082) Channel Count 8 Channels Voltage 24 VDC Nominal Switching Type High-Side Input Power 30 VDC @ 8 A max Mounting DeltaV M-series or S-series carrier Termination Screw terminals (field), Ribbon/D-shell (card) Temperature Range 0°C to 60°C (operational) Shock & Vibration 10 g, 1/2 sine 11 ms; 1 mm peak-to-peak 5–16 Hz, 0.5 g 16–150 Hz Humidity 5–95% non-condensing Airborne Contaminants ISA-S71.04 Class G3 Ingress Protection IP20 Safety Certification ATEX, North American Class 1 Div. 2, Temp Rating T4 Weight 0.2 kg FAQ Q: Can this unit be replaced while the system is powered?A: No, the unit must be de-energized before disconnection to ensure safety. Q: What field devices are compatible?A: Compatible with actuators, solenoids, relays, and other 24V field devices. Similar Models ComparisonThe KJ4001X1-BA1 provides similar power distribution but with fewer channels, making the BA2 ideal for higher-density installations.
$200.00 $100.00
-
EMERSON Emerson KJ3004X1-EA1 DeltaV Local Bus Extender Module
Product Description Emerson KJ3004X1-EA1 is a critical DeltaV M-series I/O termination module, designed to extend the local bus between I/O carriers while ensuring stable power distribution and signal integrity. This module allows system expansion without compromising communication reliability and supports high-density installations in control cabinets. ApplicationsThe KJ3004X1-EA1 is ideal for extending the I/O backbone in distributed control systems. It is typically used to link vertical or horizontal I/O carriers in DeltaV systems, supporting analog and digital field signals in process automation, safety, and remote I/O panels. Key Features Local bus interface for seamless carrier-to-carrier connection Hot-swappable design reduces downtime during maintenance Supports continuous 24V DC power distribution across connected I/O modules Industrial-grade durability: -40°C to 70°C, vibration-resistant, conformal coating for harsh environments Keyed connectors prevent misalignment and ensure proper installation LED indicators for bus power and communication diagnostics Technical Specifications Feature Specification Model KJ3004X1-EA1 Input Power 32 VDC @ 500 mA Operating Temperature -40 °C to +70 °C Shock Resistance 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak from 2–13.2 Hz; 0.7 g from 13.2–150 Hz Humidity 5–95% non-condensing Contaminant Protection ISA-S71.04 Class G3 Mounting DIN rail or DeltaV carrier Connection Type Local Bus Right Extender Certification CE, UL, FM, ATEX Zone 2 Weight Approx. 0.25 kg Installation & Maintenance NotesThis module must not be removed or inserted while the system is powered. It contains no user-serviceable parts, and disassembly or calibration is not required. Refer to DeltaV Zone 2 installation documentation for hazardous area procedures. FAQ Q: Can I add multiple KJ3004X1-EA1 units in a single bus segment?A: Yes, but ensure the total current does not exceed the carrier rating. Q: Is this module compatible with Series 1 DeltaV I/O?A: It is optimized for DeltaV M-series (Series 2) I/O; adapters may be required for older Series 1 carriers. Similar Models ComparisonThe KJ3004X1-BA1 is another bus extender with additional power injection capability, suitable for high-power I/O modules.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-CG1 I/O Carrier 8-Slot Expansion Vertical Series 2
Product Description Emerson DeltaV KJ4001X1-CG1 is an 8-slot vertical I/O carrier designed to expand DeltaV Series 2 controller nodes. This robust platform accommodates up to eight I/O modules, providing high-density signal interfacing in compact control cabinets. Its vertical orientation optimizes cabinet space while maintaining reliable system connectivity and bus stability. ApplicationsIdeal for industrial control environments, the KJ4001X1-CG1 is suitable for field signal integration including analog and digital I/O. It is frequently deployed in remote I/O panels or expansions of existing DeltaV controller setups, where hot-swap capability and environmental resilience are critical. Key Features Supports up to 8 DeltaV Series 2 I/O modules Vertical design maximizes cabinet space efficiency Integrated local bus distributes 24V DC and high-speed data to all slots Hot-swappable modules maintain system uptime during maintenance Conformal coating protects against dust, moisture, and corrosive gases Operating range from -40°C to 70°C, vibration-resistant Technical Specifications Feature Specification Model KJ4001X1-CG1 Carrier Type 8-slot Vertical I/O Interface Carrier Module Capacity 8 I/O modules with terminal blocks Mounting 35mm DIN rail or cabinet backplane Local Bus Current Up to 8 Amps Connectivity Requires vertical extender cable to controller Environmental Rating -40°C to 70°C, vibration resistant, G3 conformal coating Hot-Swap Support Yes I/O Compatibility DeltaV Series 2 I/O modules (AI, AO, DI, DO) FAQ Q: Can I populate all 8 slots with high-power analog output modules?A: Yes, but monitor total bus current. If voltage drop occurs, add a Local Bus Power Terminal (e.g., KJ3004X1-BA1). Q: Is this compatible with Series 1 DeltaV I/O?A: The carrier primarily supports Series 2 modules, but terminal blocks for Series 1 may require additional adapters. Similar Models ComparisonThe KJ4001X1-CC1 serves as the controller carrier, whereas the CG1 is purely for I/O expansion.
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ4001X1-CC1 Vertical Controller Carrier | Series 8000 Node
Product Description Overview The KJ4001X1-CC1 from Emerson is a vertical Power/Controller Carrier for DeltaV™ Series 2 systems. Engineered for installations where vertical cabinet space is limited, it provides a secure mounting platform for two controllers and two power supplies. This carrier ensures high-availability operation while managing power distribution and communication between the DeltaV Control Network and downstream I/O modules. Key Features Vertical Orientation for Space Efficiency Designed for vertical DIN-rail mounting to optimize cabinet space. Improves airflow and heat dissipation in high-density enclosures. Compatible with vertical wire ducts for neat cable management. Redundancy and Reliability Dual controller slots enable automatic, bumpless switchover. Dual power slots maintain uninterrupted local bus operation during power module failures. High-Speed Local Bus Integrated backplane supports fast data exchange between controllers and I/O modules. Minimizes latency for real-time control applications. Secure Communication Ports Provides redundant Ethernet connections for the DeltaV Control Network. Ports are reinforced for high-vibration environments to prevent accidental disconnections. Industrial-Grade Protection G3 conformal coating shields against moisture and chemical contamination. Operating range from -40°C to +70°C. Includes Carrier ID plug for automatic recognition of slot configuration. Technical Specifications Feature Specification Model Number KJ4001X1-CC1 Orientation Vertical Slot Capacity 2 Controllers + 2 Power Supplies Mounting 35mm DIN Rail Input Power 30 VDC @ 50 mA per channel Local Bus Current Up to 8 Amps Network Support Redundant Ethernet (802.3) Environmental Protection ISA-S71.04-1985 Class G3 Operating Temperature -40°C to +70°C Shock Resistance 10 g half-sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Compatibility DeltaV M-Series and S-Series Controllers Installation & Maintenance Never insert or remove the carrier while system power is applied. No user-serviceable components; disassembly is prohibited. Factory calibration is permanent; no field adjustments are required. Ensure proper vertical carrier extender cables (KJ4001X1-CK1/CL1) when connecting to I/O carriers. Applications High-density DeltaV nodes with vertical cabinet orientation Redundant controller setups requiring continuous operation Compact enclosures in industrial environments with vibration or chemical exposure FAQ Q: Can I replace a horizontal carrier with this vertical version?A: Yes, but vertical extender cables are required for proper connection to downstream I/O carriers. Q: Does this carrier support redundant power and controllers?A: Yes, it has dual slots for controllers and power modules, enabling bumpless switchover. Q: What environmental conditions can it operate in?A: The unit operates reliably from -40°C to +70°C, is vibration-resistant, and is rated for G3-level chemical exposure.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-CA1 DeltaV Power/Controller Carrier | Series 8000
Product Description Overview The KJ4001X1-CA1 from Emerson is a high-performance Power/Controller Carrier designed for DeltaV™ Series 2 distributed control systems. It serves as the backbone for nodes requiring high availability and reliability. Horizontally DIN-rail mounted, the carrier supports dual controllers and dual power supplies, enabling seamless redundancy and uninterrupted process control. It also acts as the central hub for power distribution and communication between the Control Network and downstream I/O modules. Key Features Redundancy Support Dual slots for controllers and power modules ensure continuous operation in the event of a hardware failure. Backplane design allows bumpless switchover between redundant controllers. Modular Expansion Integrated plug-in interface enables easy connection of additional I/O carriers (e.g., KJ4001X1-BE1). System scalability without complex external wiring or downtime. Integrated Communication Bus Redundant Ethernet ports for reliable Control Network connectivity. Local bus supplies 24V DC and high-speed data to all connected I/O modules. Hardware Address Management Physical Carrier ID (Address Plug) ensures correct slot recognition. Replacement controllers automatically inherit slot configuration. Industrial-Grade Reliability Operating temperature: -40°C to 70°C G3 conformal coating protects against humidity and corrosive substances Shock and vibration resistant, suitable for cabinets near heavy machinery Technical Specifications Feature Specification Module Type Power/Controller Carrier Slot Capacity 2 Controllers + 2 Power Supplies Mounting Horizontal 35mm DIN Rail Input Power 24V DC via T-box connectors; 250 VAC / 60 VDC @ 1 A per channel Local Bus Current Up to 8 A Environmental Protection ISA-S71.04 Class G3, Conformal Coating Operating Temperature -40°C to +70°C Shock Resistance 10 g half-sine wave, 11 ms Vibration Resistance 1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz) Series Compatibility DeltaV Series 2, M-Series / S-Series Installation & Maintenance Always power down the system before inserting or removing the carrier. No user-serviceable parts; disassembly is not allowed. Ensure T-box power connectors are securely tightened to prevent intermittent bus errors. Calibration is factory-configured; no field adjustments are required. Applications High-availability process control nodes Redundant DeltaV controller setups Industrial environments with extreme temperature or vibration conditions FAQ Q: Can additional I/O carriers be connected directly to this module?A: Yes, it has a plug-in interface for seamless expansion with compatible carriers. Q: Is this module suitable for hazardous areas?A: Yes, but installation must follow Emerson’s Zone 2 safety instructions. Q: Does it require calibration?A: No, it comes factory-calibrated and does not require field adjustments.
$200.00 $100.00
-
EMERSON Emerson KJ4001X1-CA1 DeltaV Series 2 I/O Carrier Module Industrial
Product Description Overview The KJ4001X1-CA1 from Emerson is a robust horizontal I/O carrier designed for the DeltaV Series 2 System 8000. It provides a secure platform for controllers and power supplies, enabling reliable communication and power distribution within a distributed control system. Engineered for hazardous environments, this carrier is fully compliant with Zone 2 certifications, ensuring safe operation in demanding industrial settings. Key Features Modular Design and Expansion Rigid horizontal carrier with DIN-rail mounting for secure installation. Supports two DeltaV controllers and two system power supplies. Scalable design allows integration with additional carriers via plug-in bus connectors. Redundancy for High Availability Dedicated slots for redundant controllers and power supplies. Maintains local bus power and control continuity even if one controller or supply fails. Integrated Communication Infrastructure Built-in local bus connects controllers to I/O modules. Dual Ethernet ports support redundant 10/100 Mbps connections for high-speed network integration. Safe Handling and Maintenance Carrier ID plug ensures software configuration aligns with physical installation. T-box power connectors simplify wiring and reduce installation errors. Removal and insertion only allowed with system power de-energized to meet safety requirements. Industrial-Grade Durability Operates from -40°C to +70°C. Conformal coating provides resistance to moisture and corrosive airborne contaminants (ISA-571 Class G3). Shock- and vibration-resistant design ensures reliable field operation. Technical Specifications Feature Specification Model KJ4001X1-CA1 Type Power/Controller Carrier (Horizontal) Controller Slots 2 Power Supply Slots 2 Mounting Standard 35 mm DIN Rail Local Bus Current Up to 8 A Input Power 250 VAC / 60 VDC, 1 A per channel Network Interface Redundant 10/100 Mbps Ethernet Operating Temperature -40°C to +70°C Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% non-condensing Hazardous Location Compliance Class I, Zone 2 Contaminant Resistance ISA-571.04 Class G3 Application Scenarios Ideal for chemical, oil and gas, and process manufacturing environments, the KJ4001X1-CA1 supports mission-critical operations where redundancy, durability, and safe operation in hazardous zones are essential. FAQ Q: Can this carrier be installed in hazardous zones?A: Yes, it is certified for Class I, Zone 2 hazardous areas. Q: How many controllers can it hold?A: It accommodates two controllers, supporting full redundancy. Q: Can power supplies be replaced without shutting down the system?A: No, system power must be de-energized during installation or removal to ensure safety. Q: Can additional I/O carriers be connected?A: Yes, via the plug-in bus connector for scalable system expansion. Similar Models: KJ4001X1-BE1 (I/O expansion carrier), KJ4001X1-DA1 (vertical variant)
$200.00 $100.00
-
EMERSON Emerson KJ1501X1-BB1 DeltaV Series 2 Controller Module Industrial
Product Description Overview The KJ1501X1-BB1 from Emerson is a high-performance DeltaV Series 2 System 8000 Controller, designed for mission-critical distributed control applications. It serves as the central processing unit for I/O modules, executing complex control routines, managing field device data, and maintaining reliable communication across the DeltaV network. Key Features High-Speed Real-Time Control Executes continuous, batch, and advanced control logic with precision. Supports comprehensive DeltaV function blocks, from PID loops to interlocking sequences. Redundant Operation for Maximum Uptime Fully supports hardware redundancy, allowing seamless failover between primary and standby units. Ensures uninterrupted process control in critical applications. Seamless Integration Auto-detects and configures when installed in DeltaV horizontal or vertical carriers. Reduces commissioning time and simplifies system setup. Reliable Industrial Communication Dual integrated Ethernet ports provide secure data exchange with operator stations. Supports synchronization between redundant controllers and communication with other DeltaV nodes. Rugged Design for Harsh Environments Operates from -40°C to +70°C with passive cooling. Conformal coating protects against corrosive vapors and airborne contaminants (ISA-571 Class G3). Shock and vibration resistant for industrial deployment. Technical Specifications Feature Specification Model KJ1501X1-BB1 Series DeltaV Series 2 Input Voltage 12 VDC @ 14.8 A / 24 VDC @ 6.1 A Output Voltages 12 VDC @ 13 A (12 V input), 12 VDC @ 8 A (24 V input), 5.1 VDC @ 2 A, 3.4 VDC @ 2 A Total Output Power 10.2 W from 5.1 VDC and 3.4 VDC Mounting DeltaV Controller Carrier (horizontal/vertical) Network Redundant Ethernet (802.3) I/O Capacity Up to 64 local I/O cards depending on scan rate Operating Temperature -40°C to +70°C Shock Resistance 10 g, 1/2 sinewave, 11 ms Vibration Resistance 1 mm p-p, 2–13.2 Hz; 0.7 g, 13.2–150 Hz Humidity 5–95% non-condensing Contaminant Resistance ISA-571.04 Class G3 Application Scenarios The KJ1501X1-BB1 is ideal for complex process industries, including chemical, pharmaceutical, power generation, and water treatment facilities. It ensures fast loop execution, reliable redundancy, and durable operation in challenging environments. FAQ Q: Can this controller operate in extreme temperatures?A: Yes, it is rated for continuous operation between -40°C and +70°C. Q: How does redundancy work for this controller?A: Installing two units in a redundant pair allows seamless failover without process interruption. Q: What is the maximum number of I/O cards supported?A: Up to 64 local I/O modules, depending on configured scan rates. Q: Does it require active cooling?A: No, the design uses passive cooling, enhancing reliability and MTBF. Similar Models: KJ1500X1-BB1 (lower I/O capacity), KJ1502X1-BB1 (enhanced processing power)
$200.00 $100.00
-
EMERSON Emerson KJ3004X1-BA1 | DeltaV Local Bus Power Module
Product Description Product Overview The Emerson KJ3004X1-BA1 is a Local Bus Power Terminal designed for the DeltaV™ Distributed Control System (DCS). It acts as the primary interface between the DeltaV controller and I/O modules, injecting regulated 24 VDC into the local bus to power connected I/O cards and maintain robust communication across the system. This terminal supports plug-and-play installation and is suitable for both horizontal and vertical carrier configurations. Key Features Provides stable 24 VDC local bus power for DeltaV I/O modules. Supports hot-swapping to minimize maintenance downtime. Compatible with M-series and S-series DeltaV carriers. Redundancy-ready to maintain system uptime in critical processes. Front-panel LED indicators for immediate bus power and fault status. Designed for harsh industrial conditions with G3 conformal coating. Supports H1 Fieldbus communication protocol for real-time device integration. Performance Characteristics Power Distribution and Stability Ensures even power delivery across the DeltaV local bus. Maintains signal integrity for reliable communication with I/O modules. Redundancy and Reliability Works in redundant setups to provide seamless failover. Prevents process interruptions if the primary bus power fails. Hot-Swappable Design Can be removed or replaced under power without shutting down the system. Reduces operational downtime during maintenance or upgrades. Environmental Resilience Operating Temperature: -40°C to 70°C. Shock and Vibration: Engineered to withstand plant-floor conditions. G3 Coating: Protects internal electronics from moisture and corrosive gases. Diagnostics and Monitoring Status LEDs show bus power health at a glance. Provides rapid visual feedback for troubleshooting and maintenance. Technical Specifications Feature Specification Model Number KJ3004X1-BA1 Module Type Local Bus Power Terminal / I/O Interface Input Power 24 VDC standard industrial Bus Type DeltaV Local Bus (Series 2) Maximum Current 600 mA Communication H1 Fieldbus protocol support Mounting DeltaV I/O Carrier (Horizontal or Vertical) Protection Internal fuse and current-limiting circuitry Compatibility M-Series and S-Series DeltaV Carriers Operating Temperature -40°C to 70°C Environmental Protection G3 Conformal Coating LED Indicators Bus Power Status, Fault Detection Applications Ideal for DeltaV system nodes where reliable local bus power is required, including chemical, pharmaceutical, and energy production plants. Supports integration of field instruments and I/O modules for real-time process monitoring and control. FAQ Q: Can the KJ3004X1-BA1 be replaced without powering down the system?A: Yes, it supports hot-swapping in line with DeltaV’s plug-and-play philosophy. Q: What is the maximum current capacity?A: The module can provide up to 600 mA to connected I/O modules. Q: Which carriers are compatible?A: M-series and S-series DeltaV I/O carriers are fully supported. Q: Does it support communication protocols?A: Yes, it supports the H1 Fieldbus protocol for real-time communication with field devices.
$200.00 $100.00
-
EMERSON Emerson KJ2002X1-BA1 | DeltaV MQ Controller Module
Product Description Product Overview The Emerson KJ2002X1-BA1 is an M-series MQ Controller for the DeltaV™ Distributed Control System (DCS), acting as the processing core for a control node. It executes local control logic, manages I/O modules, and interfaces with plant networks for advanced process automation. This controller is suitable for both standalone and redundant configurations, ensuring high availability and precise process control. Key Features High-Performance Processing: Powered by a high-speed RISC processor for rapid execution of control loops and function blocks. Advanced Control: Supports PID control, batch sequencing, and complex function block calculations. Redundancy Support: Enables seamless failover between primary and secondary controllers. I/O Flexibility: Automatically detects I/O modules on the DeltaV carrier for plug-and-play integration. Industrial Reliability: Fanless design with self-diagnostics for extended MTBF and low maintenance. Performance Highlights Real-Time Control Execution Handles high-speed process loops with sub-second execution. Executes both standard and advanced function blocks with high precision. Redundancy and Failover Operates in primary/secondary mode with automatic state synchronization. Ensures uninterrupted process output if the primary controller fails. Communication and Networking Redundant Ethernet ports for communication with workstations and other controllers. Integrates with HART, Foundation Fieldbus, Profibus, and DeviceNet through I/O carriers. Plug-and-play auto-sensing of connected I/O modules simplifies engineering setup. Maintenance and Reliability Continuous self-monitoring of internal health, memory, and communication status. Hot-swappable capability in redundant configurations allows controller replacement without downtime. Fanless, rugged design reduces dust accumulation and mechanical failures. Technical Specifications Feature Specification Model Number KJ2002X1-BA1 Alternate Part Numbers VE3002, 12P1442X042 Module Type M-Series MQ Controller Input Power 12 VDC via DeltaV Controller Carrier Local Bus Power 3.3 VDC @ 500 mA max, 5 VDC @ 750 mA max Max Power Consumption 5 VDC, 1.4 A Operating Temperature 0°C to 60°C (standard) / -40°C to 70°C (industrial-rated) Storage Temperature -40°C to 85°C Relative Humidity 5% to 95% non-condensing Shock/Vibration IEC 60068-2 Compliant Dimensions 30 x 20 x 20 cm Weight 2 kg Mounting DeltaV Power/Controller Carrier, 2-wide slot Redundancy Active Primary/Secondary support, hot-swappable Applications Ideal for high-speed process control applications in chemical, pharmaceutical, energy, and manufacturing plants. Suitable for both standalone and fully redundant control nodes within a DeltaV M-series architecture. FAQ Q: How many I/O signals can this controller manage?A: Typically supports up to 750 Device Signal Tags (DSTs), depending on system configuration. Q: Can this controller be replaced without shutting down the process?A: Yes, in redundant configurations, hot-swapping is supported. Q: What does the BA1 revision indicate?A: Standard M-series revision with compatibility for legacy and current DeltaV systems. Q: What networking options are supported?A: Redundant Ethernet, HART, Foundation Fieldbus, Profibus, and DeviceNet via the I/O carriers.
$200.00 $100.00
-
EMERSON Emerson KJ3001X1-BJ1 | DeltaV Digital Input Module 8-Channel
Product Overview The Emerson KJ3001X1-BJ1 is an 8-channel digital input module for the DeltaV™ Distributed Control System (DCS). Designed to integrate seamlessly into DeltaV M-series power/controller carriers, it converts field signals into reliable digital inputs for process control. The module supports dry contact, solid-state, and voltage inputs while providing built-in diagnostic monitoring for system reliability. Key Features Eight Optically Isolated Channels: Ensures immunity from electrical interference. Multi-Signal Support: Compatible with dry contacts, solid-state devices, and voltage signals. Integrated Diagnostics: Includes LEDs for individual channel and module status, plus fault reporting. Robust Construction: G3 conformal coating protects against corrosive industrial environments. Wide Operating Temperature: Functional from -40°C to 70°C. Easy Maintenance: Modular plug-in design allows hot-swappable operation in redundant setups. Performance Highlights Stable Dual-Rail PowerThe KJ3001X1-BJ1 functions as a local bus power regulator: 5 VDC Rail: Powers controller logic and CPUs. 12 VDC Rail: Powers I/O modules and communication interfaces.This separation stabilizes the power supply and protects sensitive electronics from field voltage fluctuations. Redundancy and High Availability 1:1 Redundancy: Supports load sharing across paired modules. Hot-Swap Capability: Replace a failed module without interrupting system operation. Advanced Monitoring Remote Diagnostics: Sends real-time health status to DeltaV Diagnostic Explorer. Local LED Indicators: Green for normal operation, Red for faults, enabling quick field troubleshooting. Industrial-Grade Design Fanless Cooling: Convection-cooled design reduces dust accumulation and mechanical failure. Environmental Resistance: G3 coating and high temperature tolerance ensure operation in challenging industrial conditions. Technical Specifications Feature Specification Model Number KJ3001X1-BJ1 Module Type Digital Input Module / Local Bus Power Controller Input Channels 8 Optically Isolated Channels Supported Inputs Dry Contact, Solid-State, Voltage Output Power Rails 5 VDC and 12 VDC Current Capacity Up to 8 Amps Operating Temperature -40°C to 70°C Protection Features Over-voltage, Short-circuit, Thermal Redundancy Support Yes, hot-swappable with paired modules Mounting DeltaV Power/Controller Carrier Applications Ideal for industrial control processes requiring reliable digital input monitoring, such as chemical processing, oil & gas, water treatment, and manufacturing automation. Suitable for both standalone and redundant DeltaV M-series nodes. FAQ Q: What input types does this module support?A: Dry contact, solid-state, and voltage signals. Q: Can it be replaced while the system is running?A: Yes, it is hot-swappable in redundant configurations. Q: What is the operating temperature range?A: -40°C to 70°C for industrial reliability. Q: What does the BJ1 revision signify?A: G3 conformal coating and updated internal components for enhanced environmental resistance.
$200.00 $100.00
-
EMERSON Emerson KJ3002X1-BF1 | DeltaV RTD Input Module 8-Channel
Product Overview The Emerson KJ3002X1-BF1 is an 8-channel RTD input module for the DeltaV™ Distributed Control System (DCS). It converts signals from RTD, thermocouple, mV, and VDC sensors into accurate digital readings for the controller. Designed for industrial process control, it ensures reliable temperature monitoring and smooth integration with DeltaV M-series hardware. Key Features Multi-Sensor Compatibility: Supports RTD, thermocouple, mV, and VDC inputs. Eight Channels: Measures multiple points simultaneously with high precision. High Accuracy: ±0.1% full-scale for reliable data acquisition. Rapid Update: Reads all eight inputs every 100 ms for near real-time control. Shielding Included: Minimizes signal noise and electrical interference. Compact Modular Design: 8-wide form factor for efficient carrier installation. Performance Characteristics Reliable Temperature ConversionThe module transforms analog sensor readings into stable digital values for DeltaV controllers, enabling precise process control and data logging. Local Bus IntegrationPowered by 12 VDC at 160 mA, the module draws only 1.5 W, making it energy-efficient while maintaining performance. The regulated internal bus isolates sensitive controller electronics from bulk 24 VDC supply fluctuations. Redundancy and Hot-Swap CapabilityWhen deployed in redundant configurations, the KJ3002X1-BF1 allows seamless failover: If one module fails, the partner module immediately takes over the load. Hot-swappable design ensures no process interruption during maintenance. Industrial Reliability Convection Cooling: Fanless architecture reduces mechanical failures and dust accumulation. Wide Operating Range: Functions in temperatures from -40°C to +85°C and standard industrial humidity. Rugged Construction: Meets EMI/RFI resistance standards, suitable for harsh environments. Technical Specifications Feature Specification Model Number KJ3002X1-BF1 Module Type RTD Input Module Number of Channels 8 Input Types RTD, Thermocouple, mV, VDC Accuracy ±0.1% Full Scale Update Rate 8 channels in 100 ms Shielding Included Local Bus Power 12 VDC, 160 mA Power Consumption 1.5 W Operating Temperature -40°C to +85°C Storage Temperature -40°C to +85°C Dimensions (WxHxD) 8-wide (standard DeltaV carrier) Mounting DeltaV Power/Controller Carrier Protection EMI/RFI resistant Applications Ideal for high-accuracy temperature monitoring in chemical, oil & gas, water treatment, and process industries. Suitable for both standalone and redundant DeltaV M-series control nodes. FAQ Q: What types of sensors are supported?A: RTD, thermocouple, mV, and VDC sensors. Q: Can the module be replaced while the system is running?A: Yes, it is hot-swappable when used in a redundant setup. Q: How fast does the module update measurements?A: All eight channels update every 100 milliseconds for near real-time monitoring. Q: Is it suitable for harsh industrial environments?A: Yes, it operates from -40°C to +85°C and meets EMI/RFI resistance standards.
$200.00 $100.00
-
EMERSON Emerson KJ3002X1-BC1 | DeltaV Analog Input Module 8-Channel
Product Overview The Emerson KJ3002X1-BC1 is an 8-channel analog input module engineered for the DeltaV™ Distributed Control System (DCS). It converts field analog signals into precise digital data for controllers and I/O modules, ensuring seamless integration and reliable performance in process control environments. Key Features Eight Independent Channels: Processes multiple 4–20 mA signals simultaneously. Local and Field Bus Power: Operates from 12 VDC local bus at 150 mA and supplies 24 VDC at 300 mA to connected field devices. High Accuracy: ±0.1% full-scale measurement ensures precise control and monitoring. Robust Industrial Design: Compact plug-in module with rugged housing suitable for harsh environments. Wide Environmental Tolerance: Operates from 0°C to 60°C, with storage from -40°C to 85°C. Shock and Vibration Resistance: Survives 10g shock (½ sine, 11 ms) and vibration up to 0.5g, 16–150 Hz. Performance Characteristics Reliable Analog-to-Digital ConversionThe module converts incoming 4–20 mA analog signals into high-resolution digital data, maintaining signal integrity even in electrically noisy environments. Redundancy and System IntegrationWhen paired with redundant DeltaV modules, the KJ3002X1-BC1 ensures uninterrupted data acquisition and supports active load sharing, providing high availability for mission-critical processes. Diagnostics and Status Feedback Front Panel LEDs: Quick identification of power and fault conditions. Software Integration: Communicates module health to DeltaV Explorer and Diagnostics applications, allowing proactive maintenance. Industrial Reliability Fanless Cooling: Reduces mechanical failure risks and eliminates dust accumulation issues. Environmental Protection: Resistant to airborne contaminants, vibration, and thermal stress common in process industries. Technical Specifications Feature Specification Model Number KJ3002X1-BC1 Module Type 8-Channel Analog Input Input Signal 4–20 mA Number of Channels 8 Local Bus Power 12 VDC at 150 mA Field Circuit Power 24 VDC at 300 mA Accuracy ±0.1% Full Scale Operating Temperature 0°C to 60°C Storage Temperature -40°C to 85°C Shock 10g, ½ sine, 11 ms Vibration 1 mm peak-to-peak (5–16 Hz), 0.5g (16–150 Hz) Relative Humidity 5% to 95%, non-condensing Dimensions (WxHxD) 42 mm × 125 mm × 105 mm Weight 0.2 kg Mounting DeltaV Power/Controller Carrier Protection Over-voltage, Over-current, Reverse Polarity Applications Ideal for connecting sensors, transmitters, and other analog field devices to DeltaV M-series control nodes. Common in chemical, oil & gas, water treatment, and process manufacturing environments where precision signal acquisition is essential. FAQ Q: Can this module handle high-accuracy measurements for process control?A: Yes, it provides ±0.1% full-scale accuracy across all eight channels. Q: Is it compatible with redundant DeltaV setups?A: Yes, it supports load-sharing and seamless integration in redundant nodes. Q: What input types are supported?A: Compatible with 4–20 mA analog signals from field transmitters. Q: Can it survive harsh industrial conditions?A: Yes, the module tolerates shock, vibration, extreme temperatures, and high humidity environments.
$200.00 $100.00
-
EMERSON Emerson KJ3001X1-BB1 | DeltaV 8-Channel Digital Input Module
Product Overview The Emerson KJ3001X1-BB1 is a high-performance 8-channel digital input module designed to connect dry contact field devices to DeltaV™ Distributed Control Systems (DCS). It provides precise, reliable input signal conversion for process control applications, ensuring controllers and I/O modules receive accurate digital signals from the field. Key Features 8 Independent Input Channels: Supports multiple dry contact devices simultaneously. Dry Contact Compatibility: Handles standard 24 VDC input signals with 5 mA per channel. Compact Industrial Form Factor: Fits DeltaV power/controller carriers, optimizing space in control cabinets. Local Bus Integration: Receives 12 VDC at 100 mA directly from the local bus. LED Indicators: Provides immediate visual feedback for power and input status. Durable Design: Withstands vibration, shock, airborne contaminants, and wide temperature ranges. Performance Characteristics Stable Signal ConversionConverts field 24 VDC dry contact signals into precise digital inputs for DeltaV controllers, protecting sensitive microprocessors from voltage fluctuations and ensuring reliable data transmission. Redundancy and High AvailabilitySupports 1:1 redundancy for critical systems: Dual modules can operate in hot standby or load-sharing mode. In the event of a failure, the backup module instantly assumes full operation without interrupting control processes. Integrated Diagnostics Front-Panel LEDs: Display “Power OK” and “Fault” conditions for quick local troubleshooting. System Alerts: Communicates with DeltaV Diagnostic Explorer to report module health, input loss, or voltage anomalies. Industrial Reliability Fanless Cooling: Convection design reduces mechanical failure risk and prevents dust accumulation. Wide Environmental Tolerance: Rated for -40°C to 70°C operation, vibration, shock, and G3-class contaminants. Technical Specifications Feature Specification Number of Channels 8 digital inputs Input Type Dry contact Input Voltage 24 VDC Input Current 5 mA per channel Local Bus Power 12 VDC at 100 mA Field Circuit Rating 24 VDC at 5 mA per channel Operating Temperature 0°C to 60°C Shock 10g, sinewave, 11 ms Vibration 1 mm peak-to-peak 5–16 Hz; 0.5g 16–150 Hz Airborne Contaminants ISA-S71.04-1985 Class G3 Relative Humidity 5–95%, non-condensing Ingress Protection IP20 Dimensions 3.8 cm × 10.7 cm × 12.7 cm (1.5" × 4.2" × 5.0") Weight 0.2 kg (7.1 oz) Terminal Block Key B1 Applications Ideal for M-series DeltaV control nodes where dry contact field inputs are required, such as sensors, switches, or relay-based signals. Ensures reliable monitoring in chemical, oil & gas, and process control environments. FAQ Q: Can this module interface with other DeltaV input modules?A: Yes, fully compatible with M-series DeltaV controllers and I/O modules. Q: What redundancy configurations are supported?A: Supports 1:1 hot-standby redundancy to maximize uptime. Q: What is the maximum input current per channel?A: 5 mA per channel at 24 VDC nominal. Q: Can it operate in harsh environments?A: Yes, rated for vibration, shock, and Class G3 airborne contaminants.
$200.00 $100.00
-
EMERSON Emerson KJ3002X1-BB1 | DeltaV 8-Channel Analog Output Module
Product Overview The Emerson KJ3002X1-BB1 is an 8-channel analog output module engineered for DeltaV™ Distributed Control Systems. It provides precise 4-20 mA current loop outputs for controlling field devices, including actuators and analog-driven equipment. Designed for compact integration, this module ensures accurate signal transmission for critical process automation tasks. Key Features Eight Independent Channels: Each channel configurable to support multiple output devices. High-Precision Analog Output: 16-bit DAC with ±0.15% full-scale accuracy at 25°C. DeltaV Compatibility: Seamlessly integrates with M-series and S-series controllers. Compact and Reliable Design: Fanless operation and robust construction for long-term stability. Electrical Isolation: 250 VAC between channels and system to protect against ground loops. Fast Update Rate: Typical 50 ms per channel for responsive process control. Technical Specifications Feature Specification Channels 8 independently configurable outputs Output Range 4-20 mA nominal Resolution 16-bit Digital-to-Analog Conversion Accuracy ±0.15% of span at 25°C Load Resistance Max 600 Ω at 24 VDC Input Power 24 VDC ±10% Power Consumption Max 2.8 W Operating Temp -40°C to 70°C Relative Humidity 5–95%, non-condensing Isolation 250 VAC between channels and system Dimensions 12.5 cm H × 4.2 cm W × 10.5 cm D Weight 0.25 kg approx. Update Rate 50 ms per channel typical Applications Ideal for controlling actuators, valves, and other analog field devices in process industries such as chemical, oil & gas, power generation, and water treatment. Provides reliable, precise outputs for mission-critical process automation. FAQ Q: Can this module be integrated with other DeltaV modules?A: Yes, it is fully compatible with M-series and S-series DeltaV controllers. Q: How precise is the analog output?A: The module uses a 16-bit DAC, achieving ±0.15% of span accuracy at 25°C. Q: Does it require cooling fans?A: No, the design is fanless and uses natural convection to maintain safe operating temperatures. Q: What is the recommended load resistance?A: Maximum 600 Ω at 24 VDC to ensure proper 4-20 mA output operation.
$200.00 $100.00
-
EMERSON Emerson KJ3002X1-BG1 | DeltaV M-Series System Power Supply
Product Overview The Emerson KJ3002X1-BG1 is a high-performance system power supply for DeltaV™ Distributed Control Systems. It converts bulk 24 VDC input into regulated 12 VDC and 5 VDC outputs to power controllers and I/O modules. Designed as a modular plug-in unit for DeltaV carriers, it provides reliable, low-noise DC power for critical process control operations. Key Features Dual-Voltage Output: Supplies stable 12 VDC for I/O modules and communication circuits, and 5 VDC for controller logic. Redundancy Support: Compatible with 1:1 redundant configurations to maintain continuous system operation. Active Load Sharing: Balances power between redundant modules to extend component life. Diagnostic Indicators: Front-panel LEDs display power status, errors, and redundancy health. High Efficiency Design: Convection cooling minimizes heat, eliminating internal fans and increasing MTBF. Protection Circuitry: Built-in safeguards against over-voltage, short-circuits, and thermal overload. Technical Specifications Feature Specification Input Power 24 VDC (Bulk Supply) Output Power 12 VDC and 5 VDC Output Current 8 A typical total for the local bus Local Bus Power 12 VDC @ 150 mA Bussed Field Power 30 VDC @ 3 A per card Field Circuit 30 VDC @ 1 A per channel, 3 A per card Ambient Temperature -40°C to 70°C (-40°F to 158°F) Shock & Vibration Meets ISA-571.04 -1985 Relative Humidity 5–95%, non-condensing IP Rating IP20 Mounting DeltaV Power/Controller Carrier Redundancy 1:1 supported Applications Ideal for DeltaV M-Series nodes in chemical, oil & gas, power generation, and other process industries. Ensures continuous, stable power for both controllers and I/O modules in high-demand environments. FAQ Q: Can this power supply be used in redundant configurations?A: Yes, the KJ3002X1-BG1 supports 1:1 redundancy when paired with another module on a redundant carrier. Q: Does it require fan cooling?A: No, the unit uses convection cooling to maintain efficiency and reliability without internal fans. Q: What protection features are included?A: Over-voltage, short-circuit, and thermal overload protection are built-in to safeguard controllers and I/O modules.
$200.00 $100.00
-
EMERSON Emerson KJ3243X1-BA1 | High-Density I/O Termination Block | DeltaV
Product Description The Emerson KJ3243X1-BA1 is a 32-channel Vertical Plus termination block designed for DeltaV™ Distributed Control Systems. It serves as a robust physical interface between field instruments and I/O modules, ensuring reliable signal transmission in high-density wiring setups. Compatible with S-series and M-series I/O modules, it mounts directly on DeltaV 2-wide or 8-wide carriers. Key Features High-Density Channel Support: 32 independent connections minimize cabinet space and optimize control room layouts. Hot-Swappable Modules: Enables maintenance without disconnecting field wiring, improving system uptime. Signal Integrity Protection: Integrated shielding and grounding paths reduce EMI, maintaining signal accuracy. Fused Channel Protection: Individual circuits safeguard I/O modules against field faults. Industrial Reliability: Built for harsh environments with shock, vibration, and temperature resistance. Technical Specifications Specification Details Channels 32 Input Voltage 24 VDC nominal, 30 VDC max Local Bus Power 12 VDC @ 150 mA Bussed Field Power 24 VDC @ 3.2 A per card Field Circuit Output 24 VDC @ 100 mA per channel Terminal Type High-density screw terminals Ambient Temperature -40°C to +70°C (-40°F to 158°F) Shock Resistance 10 g, half-sine, 11 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-571.04 Class G3 Relative Humidity 5–95%, non-condensing IP Rating IP20 Applications Ideal for process automation in industries such as chemical, oil & gas, and power generation, where high-density field connections and continuous system availability are critical. Provides secure and organized wiring for both digital and analog signals in demanding industrial environments. FAQ Q: Can the KJ3243X1-BA1 be used with both S-series and M-series I/O modules?A: Yes, it is compatible with both series when mounted on the appropriate DeltaV carrier. Q: Is field wiring required to be disconnected for maintenance?A: No, the hot-swappable design allows module replacement without disturbing connected field wiring. Q: What environmental conditions can it operate in?A: Supports -40°C to +70°C temperatures, vibration, shock, and non-condensing humidity up to 95%.
$200.00 $100.00
-
EMERSON Emerson KJ3222X1-BA1 8-Channel 4-20mA HART Analog Input Module
Product Description Overview The KJ3222X1-BA1 by Emerson is an 8-channel analog input card for 4-20mA HART signals, designed for the DeltaV™ Distributed Control System (DCS). It functions as a Vertical Plus I/O termination block, connecting field instrumentation to the system’s controllers. This module ensures accurate signal capture from sensors and transducers while maintaining full compliance with intrinsic safety standards for hazardous areas. Key Features Hazardous Area Certification: Certified for Zone 2 operation with approvals including II 3 G Ex nA [ic] IC Gc, II 3 G Ex nA [nL] IIC Gc, FM13ATEX0034U, and IECEx FMG 13.0015U.High Signal Integrity: Designed to reduce electrical noise and maintain precise measurement of 4-20mA HART loops.Hot-Swappable Modular Design: Supports removal or replacement without disturbing field wiring, minimizing system downtime.Robust Industrial Performance: Operates reliably in extreme temperatures (-40°C to +70°C), vibration, shock, and exposure to airborne contaminants (ISA-S71.04 Class G3).Efficient Terminal Density: Vertical Plus architecture maximizes connection density, saving cabinet space while supporting multiple I/O channels. Technical Specifications Feature Specification Module Type 8-Channel Analog Input Card (4-20mA HART) System Compatibility Emerson DeltaV M-Series / S-Series Local Bus Power 12 VDC at 150 mA Bussed Field Power 24 VDC at 300 mA Field Input Rating 24 VDC at 30 mA per channel Operating Temperature -40°C to +70°C Shock Resistance 10 g, half-sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Relative Humidity 5%–95% non-condensing Airborne Contaminants Class G3 (ISA-S71.04-1985) Terminal Block Key A1 Mounting 2-wide or 8-wide I/O carrier compatible Isolation Galvanic isolation between channels (dependent on module type) Applications Monitoring and control of 4-20mA field devices in DeltaV DCS environments Integration with process sensors and HART-enabled instrumentation Hazardous area installations requiring Zone 2 certified components High-density I/O cabinets where space efficiency is critical FAQ Q: Can the module be installed or removed while powered?A: No. System and field power must be removed before insertion or removal. Follow safety instructions for hazardous areas. Q: What types of field signals does it support?A: Supports 4-20mA analog loops, HART communication, and energy-limited sensor inputs. Q: How is misalignment prevented during installation?A: A rotary keying system ensures the terminal block is correctly matched to the I/O card. Q: Is it suitable for harsh industrial environments?A: Yes, it withstands high vibration, extreme temperature ranges, and airborne contaminants. Q: How does it compare to KJ3221X1-BA1?A: KJ3222X1-BA1 adds HART support for field diagnostics and precise analog input processing, while maintaining the same Vertical Plus modular design
$200.00 $100.00
You have seen 336 out of 731 products