DCS Control Systems
-
EMERSON Emerson KJ4001X1-NB1 S-Series Local Bus Extender for DeltaV
Product Description Overview The KJ4001X1-NB1 from Emerson is a high-performance S-series Local Bus Extender designed for the DeltaV™ Distributed Control System. It enables reliable bridging of power and communication between multiple I/O carriers, extending system capacity while maintaining signal integrity. This module is engineered for industrial-grade performance, offering robust protection against environmental stress and vibration. Key Features Seamless Bus Extension: Maintains continuity for 24V DC subsystem power and Ethernet-based local bus communications across multiple I/O carriers. Redundant and High Availability Design: Supports dual bus paths for uninterrupted communication. Industrial-Grade Durability: Resistant to extreme temperatures, vibration, shock, and airborne contaminants. Plug-and-Play Installation: Designed for straightforward integration at the end of S-series I/O carriers. Technical Specifications Feature Specification Module Type S-Series Local Bus Extender (Left-hand) Input Power 12V DC at 8A (Local Bus) Operating Temperature -40°C to +70°C Shock Resistance 10g, sine wave, 11 ms Vibration Tolerance 0.1 mm p-p (2–13.2 Hz), 0.7g (13.2–150 Hz) Humidity Range 5–95% non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3 Length Limit Combined I/O carriers and extenders ≤ 6.5 meters Cabling Requirement Interconnecting cables must be conduit-protected Servicing No user-serviceable parts; disassembly not recommended Calibration Not required Status Indicators Integrated LEDs for power and bus health Applications Ideal for extending DeltaV I/O networks across multiple cabinets in process control environments, chemical plants, and oil & gas facilities. Ensures uninterrupted bus communication while supporting hot-swappable system expansions. FAQ Q: Can the KJ4001X1-NB1 be installed while the system is powered?A: No, it must only be inserted or removed with the system powered down. Q: Is user calibration required?A: No calibration is necessary. Q: How long can I extend the local bus with multiple carriers?A: Total combined length of I/O carriers and extenders must not exceed 6.5 meters. Q: Are there similar models for comparison?A: The right-hand variant KJ4001X2-NB1 provides identical functionality for the opposite end of an I/O carrier.
$200.00 $100.00
-
EMERSON DeltaV™ KJ4006X1-BK1 Redundant Interface Terminal Block
Product Description Overview The KJ4006X1-BK1 Redundant Interface Terminal Block from DeltaV™ S-Series provides reliable connectivity for hazardous and non-hazardous environments. Designed for robust industrial automation systems, this terminal block supports modular installation with keyed I/O card compatibility to ensure safe and accurate connections. Certifications & Compliance ATEX II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) UKEX FM21UKEX0017U Class I, Division 2, Groups A, B, C, D (FM17US0286U / FM17CA0145U) Class I Zone 2 AEx/Ex ec IIC Gc Electrical Specifications Field Power: 35 VDC, 1 A Terminal Keying: Configurable per installed I/O card to prevent misconnection Environmental Specifications Operating Temperature: -40°C to +70°C Shock Resistance: 10 g, ½ sine wave, 11 ms Vibration Tolerance: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants: ISA-S71.04–1985, Class G3 Relative Humidity: 5–95% non-condensing Installation & Maintenance The terminal block can be installed or removed with system power applied, provided no I/O card is present and field wiring is disconnected. The unit uses a rotary keying system to ensure proper alignment with I/O cards. No user serviceable parts are present, and calibration is not required. Installation should follow DeltaV™ S-Series Zone 2 instructions (document 12P5404) or standard hardware manuals for proper hazardous area operation. Applications Ideal for redundant industrial automation systems requiring secure and modular I/O connectivity in Zone 2 or Class I Div. 2 hazardous environments. FAQ Q: Can this terminal block be removed while system power is on?A: Yes, but only when no I/O card is installed and all field wiring is disconnected. Q: Is calibration required?A: No calibration is necessary; the unit is factory configured and maintenance-free. Q: Which I/O cards are compatible?A: Compatibility is ensured via the rotary keying system; set the terminal keys according to the I/O card in use.
$200.00 $100.00
-
EMERSON DeltaV S-Series KJ3243X1-BK1 Profibus DP Interface Card
Product Description Overview The KJ3243X1-BK1 is a high-reliability Profibus DP interface module from the DeltaV™ S-Series, designed for use in hazardous environments. It is engineered for industrial automation and process control systems, supporting Zone 2/Div. 2 safety ratings to ensure secure operation in flammable gas atmospheres. Certifications and Hazard Protection IECEx Certification: IECEx FMG 19.0019U ATEX Certification: FM19ATEX0173U, FM21UKEX0017U North America Approvals: FM17CA0145U, FM17US0286U Hazardous Area Ratings: II 3G Ex ec IIC Gc Class I, Division 2, Groups A,B,C,D Zone 2 AEx/Ex ec IIC Gc Electrical Specifications Local Bus Power: 12 VDC, maximum 600 mA System Power Requirement: Module insertion/removal requires system power to be off Terminal Interface: Rotary keying ensures compatibility between I/O cards and terminal blocks Environmental and Mechanical Specifications Operating Temperature: -40°C to +70°C Shock Resistance: 10g, half-sine wave, 11ms duration Vibration Resistance: 2–13.2 Hz: 1mm peak-to-peak 13.2–150 Hz: 0.7g Relative Humidity: 5–95%, non-condensing Airborne Contaminants: ISA-S71.04-1985 Class G3 Installation and Maintenance Hot swapping is not supported; the module must be powered down before installation or removal No user-serviceable parts; internal calibration is not required Follow DeltaV™ S-Series Zone 2 Installation Instructions and S-Series Hardware Installation Manual for safe operation Applications Ideal for chemical, petrochemical, pharmaceutical, and other industrial process automation systems requiring high safety standards. Fully compatible with DeltaV™ S-Series controllers and CHARMs modules. FAQ Q1: Can this module be replaced while the system is powered?A1: No. The system must be powered down before inserting or removing the module for safety. Q2: Does this module require calibration?A2: No. There are no adjustable components inside, so no calibration is necessary. Q3: Can it operate in high-humidity environments?A3: Yes. It supports 5–95% relative humidity under non-condensing conditions.
$200.00 $100.00
-
EMERSON Emerson KC4011X1-BA1 DeltaV Redundant Controller High-Performance DCS
Product Overview The Emerson KC4011X1-BA1 is a Series 2 redundant controller designed for the DeltaV Distributed Control System (DCS). It provides robust processing power, high-speed logic execution, and continuous communication management for demanding industrial applications. Engineered for mission-critical environments, this controller ensures uninterrupted operation through hot-standby redundancy. Technical Features System Integration and Compatibility Fully compatible with DeltaV M-series and S-series controller carriers. Seamless integration with DeltaV Control Network for data acquisition, visualization, and historical logging. Auto-detection of connected I/O modules and field devices reduces setup time. Performance and Processing High-speed execution of regulatory, batch, and discrete control logic. Supports multiple scan rates for prioritizing critical safety and process control loops. Non-volatile flash memory preserves control strategies during power cycles. Redundancy and Reliability Hot-standby redundancy enables automatic switchover without process interruption. Flash memory ensures rapid recovery and continuous operation. Built-in diagnostics monitor hardware health and communication status in real time. Environmental and Industrial Durability Wide operating temperature: -40°C to 70°C. EMI-resistant design suitable for harsh industrial conditions. Compact modular architecture for easy installation and future expansion. FAQ Q: Can the KC4011X1-BA1 work with non-redundant DeltaV systems?A: Yes, it can operate in a single-controller configuration, though redundancy is recommended for critical processes. Q: Does this controller support all DeltaV I/O modules?A: It supports most M-series and S-series modules; auto-sensing simplifies module recognition. Q: What happens if the primary controller fails?A: The hot-standby controller automatically takes over without interrupting process control. Q: What industrial conditions can it withstand?A: It is rated for -40°C to 70°C with EMI protection, suitable for harsh factory environments.
$200.00 $100.00
-
EMERSON Emerson 396657-01-0 DeltaV CPU Module | S-Series Controller Interface
Product Description Overview The Emerson 396657-01-0 is a high-performance CPU module designed for the DeltaV S-series platform, providing robust connectivity and control for distributed automation systems. It acts as a central hub for field device integration, enabling reliable communication and precise process management. Its horizontal form factor allows seamless installation in S-series carrier racks. Key Features Hot-Swappable Module: Replace or upgrade the CPU without powering down the system. Redundancy Ready: Fully compatible with redundant configurations to prevent single-point failures. Advanced Diagnostics: Provides real-time health monitoring of both the module and connected I/O devices. Electrical Isolation: High-level galvanic isolation protects control logic from field-side surges and noise. Industrial Durability: Operates reliably in harsh environments, including extreme temperatures, vibration, and EMI exposure. Technical Specifications Feature Details Series DeltaV S-Series Mounting Horizontal Carrier Input Voltage 12–24 VDC (typical via carrier) Compatibility S-Series I/O modules and controllers Environmental Rating ISA-S71.04 Class G3 (harsh environments), -40°C to 70°C operating range Certifications CE, UL, CSA, ATEX (model dependent) Diagnostics Real-time status, Bad Status reporting Backplane Communication High-speed DeltaV S-series bus for low-latency data transfer Applications Central processing for process automation in chemical, oil & gas, and pharmaceutical plants. Redundant control systems requiring high reliability and zero downtime. Environments exposed to vibration, temperature swings, or EMI. FAQ Q: Is the module compatible with all DeltaV S-series I/O cards?A: Yes, the 396657-01-0 integrates seamlessly with standard S-series modules and carriers. Q: Can I replace this CPU while the system is running?A: Yes, it supports hot-swapping, allowing maintenance without shutting down operations. Q: What protection does it have against electrical surges?A: The module includes galvanic isolation to safeguard control circuits from field-side disturbances. Q: How do I confirm the part is correct for my system?A: Verify the assembly number on the module casing matches your system documentation; 396657-01-0 is typically a sub-assembly identifier.
$200.00 $100.00
-
EMERSON Emerson 396563-06-6 ControlWave Micro CPU Module | DeltaV
Product Description Overview The Emerson 396563-06-6 is an 8-channel analog input/output External Terminal Block (ETB) engineered for DeltaV Distributed Control Systems. Serving as the physical interface between field devices and DeltaV I/O modules, it supports precise analog signal transmission while safeguarding system components with integrated channel protection. Designed for industrial environments, it provides robust performance in demanding temperature and electrical conditions. Key Technical Features Signal Protection and Reliability Each channel includes a dedicated 250 mA fuse to prevent individual field faults from affecting the entire I/O module. Current limiting circuitry reduces the risk of damage during transient voltage events. Signal Integrity Shielded design minimizes electromagnetic (EMI) and radio frequency interference (RFI) for high-fidelity analog measurement. Low-resistance terminals ensure minimal signal loss across connections. Ease of Installation and Maintenance Clearly labeled screw terminals simplify wiring and reduce installation errors. Rugged construction supports DIN rail mounting and industrial vibration tolerance. System Efficiency Compact 8-channel vertical layout maximizes cabinet space. Compatible with DeltaV mass termination cables for straightforward module integration. Technical Specifications Feature Specification Number of Channels 8 Channels Signal Type Analog Input / Analog Output (2-wire) Field Termination Screw Terminals System Termination Mass Connect to DeltaV I/O Channel Protection 250 mA Fuse per Channel Mounting 35 mm DIN Rail Operating Temperature -40°C to +70°C Nominal Voltage 24 VDC Dimensions 4.7" x 3.5" x 1.8" Weight 0.25 lbs Applications Ideal for loop-powered analog devices, the 396563-06-6 is commonly deployed in chemical, petrochemical, and power generation facilities where field device reliability and protection are critical. FAQ Q: Can this terminal block be used with both M-series and S-series DeltaV I/O modules?A: Yes, the 396563-06-6 is fully compatible with both M-series and S-series modules. Q: What type of signals does it support?A: It supports standard 2-wire analog input and output signals, typically 4–20 mA loops. Q: Does it provide individual channel protection?A: Yes, each channel has its own 250 mA fuse to isolate faults.
$200.00 $100.00
-
EMERSON DeltaV SSeries FM21UKEX0017U Terminal Block | Emerson
Overview The DeltaV SSeries Terminal Block (FM21UKEX0017U) is engineered for reliable operation in hazardous environments. Designed for use with Zone 2 installations, it ensures secure connectivity and compliance with international safety standards. This terminal block is compatible with a wide range of DeltaV SSeries I/O cards, featuring a rotary keying system that guarantees proper card alignment and system integrity. Technical Specifications Power Requirements Supply Voltage: 30 VDC Current Consumption: 200 mA Environmental Ratings Operating Temperature: -40°C to +70°C Shock Resistance: 10 g, 11 ms half-sine Vibration Tolerance: 1 mm peak-to-peak from 2–13.2 Hz; 0.7 g from 13.2–150 Hz Relative Humidity: 5–95%, non-condensing Airborne Contaminants: Class G3 per ISA-S71.04-1985 Certifications Hazardous Atmosphere: Ex ec nC IIC Gc FM Approvals: FM19ATEX0173U, FM17US0286U, FM17CA0145U, FM21UKEX0017U IECEx: FMG 19.0019U Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx/Ex ec nC IIC Gc Installation & Operation Terminal blocks can be installed or removed with system power applied only when no I/O card is present and no field wiring is connected Rotary keying system ensures proper card compatibility Keys must be set according to the specific I/O card used Maintenance No user-serviceable parts Disassembly is not permitted Calibration is not required Applications Ideal for use in process automation systems, hazardous area signal interfacing, and distributed control environments where compliance with Zone 2 / Class I Division 2 safety standards is required. FAQ Q: Can the terminal block be installed while the system is powered?A: Yes, but only if no I/O card is installed and field wiring is disconnected. Q: Does this product require calibration?A: No calibration is necessary for operation. Q: Which I/O cards are compatible?A: Compatibility is ensured through the rotary keying system; keys must match the I/O card type.
$200.00 $100.00
-
EMERSON DeltaV™ KJ4006X1-BS1 Redundant AI Terminal Block | S-Series
Product Description Overview The KJ4006X1-BS1 is a redundant 8-channel analog input (AI) terminal block from the DeltaV™ S-Series, engineered for use in hazardous environments. It provides reliable field signal acquisition and interface capabilities in Zone 2/Div. 2 locations. The module features a rotary keying system to ensure precise compatibility with I/O cards and maintain system integrity after installation. Technical Specifications Certifications & Hazard Ratings ATEX: II 3G Ex ec nC IIC Gc (FM19ATEX0173U) IECEx: IECEx FMG 19.0019U UKEX: FM21UKEX0017U North America: Class I, Div. 2, Groups A,B,C,D (FM17US0286U, FM17CA0145U) Zone 2: AEx/Ex ec nC IIC Gc Power Requirements Operating Voltage: 30 VDC Maximum Current: 200 mA Environmental Conditions Operating Temperature: -40°C to +70°C Relative Humidity: 5% to 95%, non-condensing Shock Resistance: 10g, 11ms half-sine wave Vibration Resistance: 1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz Airborne Contaminant Rating: ISA-S71.04 Class G3 Mechanical & Installation Terminal blocks can be added or removed while system power is applied only if no I/O card is installed and field wiring is disconnected Rotary keying system ensures I/O card and terminal block compatibility No user-serviceable parts; no calibration required Applications Ideal for chemical, pharmaceutical, power, and other industrial facilities requiring hazardous area signal acquisition and redundant control. Seamlessly integrates with DeltaV™ S-Series control systems for secure redundant analog input functionality. FAQ Q: Does this module require regular calibration?A: The KJ4006X1-BS1 is factory-calibrated and does not require user calibration. Q: Can it be installed or removed while powered?A: Only when no I/O card is installed and no field wiring is connected. Q: Can the module operate in extreme temperatures?A: Yes, the operating temperature range is -40°C to +70°C.
$200.00 $100.00
-
EMERSON Emerson KJ3225X1-BA1 DeltaV M-Series LocalBus Extender Port
Product Description Overview The Emerson KJ3225X1-BA1 is a DeltaV M-Series LocalBus Extender Port designed to expand I/O carrier connectivity within the DeltaV Distributed Control System. It enables seamless communication between multiple carrier rows, ensuring reliable and high-speed data transfer in demanding industrial environments. Its rugged construction and ATEX/IECEx certification make it suitable for hazardous locations. Key Features High-Speed Data Transmission: Maintains signal integrity across extended LocalBus connections, supporting precise process control. Hot-Swappable Design: Can be inserted or removed without shutting down the system, enabling continuous operation during maintenance. EMI Protection & Diagnostics: Shields against electromagnetic interference and provides LED indicators for LocalBus status, power, and port activity. Plug-and-Play Integration: Automatically recognized by DeltaV Explorer software for fast commissioning. Industrial-Grade Durability: Rated for operation between -40°C to 70°C and tested for vibration, shock, and airborne contaminants. Applications Ideal for use in chemical, petrochemical, and refining facilities where DeltaV systems require expansion across multiple I/O carriers. Its ATEX and IECEx certifications ensure compliance in potentially explosive atmospheres. Technical Specifications Specification Details Series DeltaV M-Series Module Type LocalBus Extender Port Connection Interface High-density carrier-to-carrier cable Input Power 24 VDC (sourced from carrier) Operating Temperature -40°C to 70°C (-40°F to 158°F) Shock Resistance 10 g, 11 ms, half-sine wave Vibration Tolerance 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz) Humidity 5–95% non-condensing Airborne Contaminants Class G3 Ingress Protection IP20 Certifications ATEX, IECEx, FM Mounting Dedicated I/O carrier slot Terminal Block C3 Position Installation Notes Must be installed using Emerson KJ4001X1-Cx certified extension cables for proper impedance matching. Follow DeltaV M-Series hazardous area guidelines during installation, removal, or service. FAQ Q: Can the KJ3225X1-BA1 be used in Class 1 Div 1 areas?A: It is rated for Class 1 Div 2 and ATEX/IECEx hazardous zones; confirm site-specific compliance. Q: Is the module compatible with all DeltaV M-Series carriers?A: Yes, it supports all standard M-Series carriers for LocalBus extension. Q: What maintenance is required?A: Routine inspection for physical damage and LED status monitoring; no regular calibration is needed. Q: Can multiple extenders be daisy-chained?A: Yes, multiple KJ3225X1-BA1 modules can extend the LocalBus across several carriers.
$200.00 $100.00
-
EMERSON Emerson DeltaV M-Series FM21UKEX0017U Hazardous Area Interface
Product Description Overview The DeltaV M-Series Remote Interface Unit (FM21UKEX0017U) is engineered for high-reliability operation in hazardous areas. Certified for Zone 2 applications, this interface unit provides robust communication capabilities under extreme temperature and vibration conditions. Ideal for distributed control system (DCS) integration and remote interface applications. Technical Specifications Certifications & Protection Explosion Protection: II 3G Ex nA nC IIC Gc Approval Numbers: FM16ATEX0056U, FM21UKEX0017U Ingress Protection: IP20 Power Requirements Local Bus Power: 5 VDC, max 300 mA Optional Auxiliary Power: 3.3 VDC, max 500 mA Environmental Conditions Operating Temperature: -40°C to +70°C Relative Humidity: 5% to 95%, non-condensing Shock Resistance: 10g, half-sine, 11 ms Vibration Resistance: 1 mm peak-to-peak from 2–13.2 Hz; 0.7 g from 13.2–150 Hz Airborne Contaminant Rating: ISA-S71.04 –1985 G3 Installation & Operation Insertion or removal must be performed in non-hazardous areas Communication network must not connect to sources exceeding 60 VAC or 75 VDC Contains no user-serviceable parts; calibration not required Applications Distributed Control System (DCS) remote interfacing Hazardous area industrial monitoring and control Communication interfaces in high vibration and extreme temperature environments FAQ Q: Can this unit be used in Zone 1 areas?A: No, it is only certified for Zone 2 environments. Q: Does this unit require regular calibration?A: No, it is designed for maintenance-free operation. Q: Can the unit be hot-swapped?A: No, insertion or removal is only permitted in non-hazardous areas. Q: Is this unit compatible with other DeltaV modules?A: Yes, it integrates with M-Series modules for remote interfacing.
$200.00 $100.00
-
EMERSON Emerson VE6101 Carrier Blank Cap DeltaV M-Series Protective Cover
Product Description Overview The Emerson VE6101 is a protective carrier blank designed for the DeltaV™ M-series horizontal I/O subsystem. Serving as a passive accessory, it safeguards unused I/O slots from environmental contaminants, accidental contact, and ESD events. Its precise fit ensures reliable system integrity and compliance with enclosure IP ratings. The blanking cap maintains cabinet airflow, thermal stability, and the professional appearance of installed systems. Key Features Environmental and System Protection Shields internal bus connectors from dust, metallic debris, moisture, and chemical aerosols Helps maintain airflow and thermal characteristics within I/O cabinets Prevents accidental short circuits and physical damage to exposed backplane pins Safety and Electrical Protection Reduces the risk of Electrostatic Discharge (ESD) during maintenance Supports compliance with hazardous area standards when used to seal open slots Installation and Compatibility Tool-less snap-on design allows rapid installation and removal Specifically keyed to fit DeltaV M-series horizontal carriers (e.g., KJ3204X1-BK1) Ensures a secure, professional fit with minimal cabinet modification Regulatory Support Maintains IP rating compliance Assists in meeting ATEX, Class 1 Div 2, and other hazardous area requirements Technical Specifications Feature Specification Model Number VE6101 Product Type Carrier Blank Cap / Protective Cover Compatibility DeltaV M-series Horizontal I/O Carriers Material High-impact, industrial-grade polymer Weight Approximately 45 g (0.10 lbs) Operating Temperature -40°C to 70°C Installation Snap-on, tool-less design Applications Used in DeltaV M-series DCS cabinets to protect unused I/O slots in process control, chemical, power, and manufacturing systems. Ideal for maintaining system integrity during expansion or maintenance activities. FAQ Q: Can the VE6101 be installed on all M-series carriers?A: Yes, it is designed to fit standard M-series horizontal carriers and ensures proper alignment with the internal bus. Q: Does it affect airflow or thermal performance?A: Properly installed blanking caps preserve airflow patterns and thermal stability within the I/O cabinet. Q: Is this required for hazardous location installations?A: Using blanking caps helps maintain IP ratings and supports compliance with ATEX and Class 1 Div 2 standards.
$200.00 $100.00
-
EMERSON DeltaV S-Series KJ4005X1-BH1 | FM21UKEX0017U | Emerson Module
Product Description Overview The DeltaV S-Series KJ4005X1-BH1 is a high-reliability digital automation system module designed for hazardous locations. Engineered for Zone 2 environments, it ensures stable operation in areas with potential explosive atmospheres. It supports both local bus and field power and integrates seamlessly with other DeltaV S-Series controllers and I/O cards. Certifications & Explosion Protection Explosion Protection: II 3G Ex ec IIC Gc Certification Numbers: FM19ATEX0173U, IECEx FMG 19.0019U, FM21UKEX0017U Standards Compliance: CL. I Div. 2 GP. A,B,C,D; CL. I Zone 2 AEx/Ex ec IIC Gc North American Approvals: FM17CA0145U, FM17US0286U Power Requirements Local Bus Power: 12 VDC, max 15 A Field Power (8-Wide Carrier): 30 VDC, max 3 A per card Power Precautions: Field power must not exceed 30 VDC; always disconnect power before connecting Environmental Specifications Operating Temperature: -40°C to +70°C Shock Resistance: 10g, half-sine, 11 ms Vibration Tolerance: 1 mm Peak-to-Peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Airborne Contaminants: ISA-S71.04–1985 G3 Humidity: 5–95%, non-condensing Installation & Maintenance Guidelines The system must be powered off before inserting or removing modules, carriers, extender cables, or SIS adapters. Empty carrier slots must have module cover KJ4005X1-BH1 installed. The module contains no user-serviceable parts and requires no calibration. Maximum combined length of I/O carriers and Local Bus Extenders is 6.5 meters. Interconnecting cables between enclosures must be routed through conduit. Applications Ideal for oil & gas, petrochemical, power generation, and other industrial environments requiring Zone 2 explosion protection. FAQ Q: Can the module be replaced while the system is powered?A: No, power must be disconnected before any insertion or removal. Q: Does the module require calibration?A: No calibration is needed; it is factory-calibrated. Q: Can interconnect length exceed 6.5 meters?A: No, exceeding this length may compromise bus stability.
$200.00 $100.00
-
EMERSON Emerson KJ1501X1-BK2 DeltaV S-Series System DC Power Supply
Product Description Overview The KJ1501X1-BK2 by Emerson is a system-grade DC/DC power module designed for the DeltaV™ S-Series controllers. It converts 24 VDC bulk input into multiple regulated voltages that power the core logic of S-series controllers and LocalBus communication. This supply is optimized for industrial environments requiring high reliability and redundancy. Key Features Dual-Voltage ConversionThe module efficiently converts a 24 VDC input into low-voltage rails, including 5.1 VDC and 3.4 VDC, to supply internal processor logic and high-speed communication circuits. It ensures stable power across all connected I/O modules via the DeltaV LocalBus. Redundant Operation and Fault ToleranceWhen configured in pairs, the KJ1501X1-BK2 supports seamless failover and load sharing. In case of a single supply failure, the secondary unit maintains full operational capacity without controller downtime. Integrated alarm outputs provide early fault detection. Industrial-Grade Reliability Operating temperature: -40°C to +70°C Shock tolerance: 10g, 11 ms half-sine wave Vibration resistance: 1 mm peak-to-peak (2–13.2 Hz), 0.7g (13.2–150 Hz) Conformal coating: ISA-S71.04 Class G3 protection against corrosive gases and airborne contaminants Humidity: 5–95% non-condensing Safety and DiagnosticsFront-panel LEDs indicate operational status and error conditions. The unit is certified for hazardous locations including Class 1, Div 2 and ATEX Zone 2. Technical Specifications Parameter Specification Input Voltage 24 VDC, 4.5 A nominal Output Voltage Rails 5.1 VDC at 2 A, 3.4 VDC at 2 A (40–60°C), 12 VDC at 6–8 A (40–70°C) Total Output Power 10.2 W for 5.1 VDC + 3.4 VDC combined Redundancy Dual-supply load sharing and failover support Shock & Vibration 10g half-sine, 1 mm p-p / 0.7g (13.2–150 Hz) Conformal Coating Yes, Class G3 Mounting S-Series Controller/Power Carrier Applications The KJ1501X1-BK2 is intended for S-series DeltaV systems in chemical, oil & gas, and process automation industries where continuous, reliable controller power is critical. Ideal for both indoor and remote instrument enclosures. FAQ Q: Can this module be hot-swapped?A: Yes, but only if the controller operates in a redundant pair; otherwise, removal will cause immediate system shutdown. Q: How does this supply differ from field power supplies?A: Unlike field supplies powering sensors or actuators, this system supply powers internal logic and LocalBus communication, essential for the S-series controller operation. Q: Are Emerson KJ1501X1-BK1 and BK2 interchangeable?A: They are largely compatible, but always verify firmware and system documentation before swapping models.
$200.00 $100.00
-
EMERSON Emerson KC4011X1-BQ1 DeltaV S-Series 10-Pin I/O Terminal Block
Overview The Emerson KC4011X1-BQ1 is a 10-pin I/O terminal block designed for DeltaV S-Series and DeltaV SIS systems. It ensures reliable field signal connections, simplifies wiring, and maximizes cabinet density, while providing channel isolation and short-circuit protection. Key Features S-Series Integration Compact design for higher I/O density. Compatible with S-Series I/O cards for efficient electronic marshalling. Electrical Performance Input voltage: 12–24 VDC. Max current: 2 A per point. Channel isolation and short-circuit protection. LED indicators per channel for status monitoring. Installation & Maintenance DIN-rail mountable on S-Series horizontal carriers. Screw terminals with angled access for easy wiring and maintenance. Color-coded and keyed to prevent miswiring. Environmental & Safety Operating temperature: -40°C to 70°C (-40°F to 158°F). Certified for hazardous areas: ATEX, IECEx, North American Class/Div. Built to resist corrosion, vibration, and temperature fluctuations. Technical Specifications Feature Specification Model Number KC4011X1-BQ1 Series DeltaV S-Series Type 10-Pin Standard I/O Terminal Block Mounting Horizontal Carrier Wiring Method Screw Terminal Input Voltage 12–24 VDC Max Current 2 A per point Operating Temperature -40°C to 70°C Status Indicators LED per channel Isolation Electrical separation between channels Short-Circuit Protection Included Certifications ATEX, IECEx, North American Class/Div Applications Field wiring termination for sensors and actuators. Integration with S-Series electronic marshalling cabinets. Loop checks and maintenance without system disruption. FAQ Q: Can it replace M-Series modules?A: Yes, if the horizontal carrier orientation matches. Q: Which signals are supported?A: 4–20 mA analog, digital outputs, and shielded sensor wiring. Q: Is it SIS compatible?A: Yes, supports both standard and SIS S-Series I/O.
$200.00 $100.00
-
EMERSON DeltaV S-Series FM19ATEX0173U Hazardous Area I/O Module
Product Description OverviewThe DeltaV S-Series I/O Card (FM19ATEX0173U) is engineered for operation in hazardous environments. It carries multiple international certifications and is designed for safe and reliable use in Zone 2 / Division 2 areas, providing robust control and monitoring capabilities. Hazardous Area Certifications II 3G Ex ec IIC Gc IECEx FMG 19.0019U FM21UKEX0017U Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx/Ex ec IIC Gc FM17CA0145U / FM17US0286U Complies with ISA-S71.04 G3 airborne contamination standard Power Specifications Local Bus Power: 12 VDC, 150 mA Bussed Field Power: 24 VDC, 3.2 A per card Channel Power: 24 VDC, 100 mA per channel Environmental & Mechanical Specifications Operating Temperature: -40°C to +70°C Vibration: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Shock: 10 g, half-sinewave, 11 ms Relative Humidity: 5–95%, non-condensing Airborne Contaminants: Class G3 Installation & Maintenance Do not insert or remove the module while system power is on Field power must be disconnected before installation or removal Rotary keying ensures correct terminal block and I/O card alignment No user-serviceable parts; factory-calibrated and maintenance-free ApplicationsDesigned for chemical, petrochemical, and natural gas facilities. Supports fieldbus and distributed I/O architectures, seamlessly integrating with DeltaV S-Series control systems. FAQ Q: Can the I/O card be replaced while system power is on?A: No. Both field and system power must be disconnected for safe removal or installation. Q: Is periodic calibration required?A: No. The unit is factory-calibrated and does not require user maintenance. Q: Can it operate in high humidity environments?A: Yes. It supports 5–95% relative humidity, non-condensing. Similar Model Comparison FM17US0286U: Similar hazardous certifications, slightly lower current rating FM21UKEX0017U: Enhanced explosion-proof design for higher temperature environments
$200.00 $100.00
-
EMERSON Emerson KJ3241X1-BK1 I/O Termination Block | DeltaV M-Series
Product Description Overview The Emerson KJ3241X1-BK1 is a high-performance I/O termination block for DeltaV™ DCS, connecting field wiring to M-series I/O modules. Designed for redundancy, it ensures continuous operation in demanding industrial environments. Key Features Redundant I/O Support: Dual-path connection for failover without downtime. Hot-Swap Capability: Insert or remove modules safely under power. Signal Protection: Isolated pathways reduce EMI and voltage spikes. Keyed Terminal Blocks: Prevents incorrect module insertion. Durable Design: Withstands -40°C to 70°C, vibration, and shock. Technical Specifications Parameter Specification I/O Slots 8-wide Power 12 VDC, 210 mA Mounting DIN Rail / Carrier Temperature -40°C to +70°C Shock 10 g, 11 ms Vibration 1 mm (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% Non-condensing Contaminant Resistance ISA-S71.04 Class G3 Hazardous Area ATEX II 3G, FM Class I Div. 2, IECEx Applications Ideal for chemical, power, and refinery environments requiring continuous signal integrity and redundant operation.
$200.00 $100.00
-
EMERSON Emerson DeltaV KL3106X1-LS1 Safety Discrete Input CHARM
Product Description Overview The Emerson DeltaV KL3106X1-LS1 is a single-channel Discrete Input CHARM designed for the DeltaV LS (Logic Solver) series. It provides reliable monitoring of 24V DC dry contact signals from safety-critical field devices while maintaining SIL 3-level safety and intrinsic isolation. Key Features SIL 3 Safety Integration: Compliant with IEC 61508/61511, ensures fast and deterministic reporting of discrete input states. Electronic Marshalling: Flexible I/O mapping, supports late binding to simplify wiring and cabinet design. Fault Detection: Detects open/short circuits, LED status for quick diagnostics. Environmental Robustness: ISA-S71.04 Class G3 coating, operating range -40°C to +70°C. Hot-Swappable: Can be replaced without powering down adjacent modules. Specifications Feature Specification Input Type 24V DC Dry Contact (Low-Side) Channel Count 1 Isolation Galvanic isolation LED Indicators Green = Normal, Red = Fault CHARM Bus Power +6.3 VDC at 0 mA Field Circuit Power +24 VDC at 23 mA Energy-Limited Output 24V DC, max 100 mA Operating Temp -40°C to +70°C Shock 10g, 11 ms Vibration 1 mm (5–16 Hz), 0.5g (16–150 Hz) Environmental ISA-S71.04 Class G3 Dimensions 5.1 × 1.9 × 3.2 cm Weight 0.03 kg Applications Safety switches, level sensors, and emergency stop monitoring in SIL 3 loops. Hazardous area installations in chemical, petrochemical, and oil & gas plants. FAQ Q: Can it be replaced under power?A: Yes, it is hot-swappable within LS-series safety cabinets. Q: Is calibration required?A: No, it is factory-calibrated and maintenance-free.
$200.00 $100.00
-
EMERSON Emerson DeltaV KL3106X1-BA1 I.S. Discrete Input CHARM Module
Product Description Overview The Emerson DeltaV KL3106X1-BA1 is a high-performance, Intrinsically Safe (I.S.) Discrete Input CHARM designed for the DeltaV Electronic Marshalling system. It allows safe, precise interfacing with 24V DC dry contact field devices in hazardous areas while eliminating the need for external I.S. barriers. This module combines signal detection, energy-limiting circuitry, and galvanic isolation in a single compact footprint, streamlining installation in Zone 0/Zone 1/Class I Div 1 environments. Key Features Intrinsically Safe Design Built-in galvanic isolation and energy-limiting electronics provide full compliance with ATEX, IECEx, FM, and CSA standards. Suitable for direct connection to “Simple Apparatus” or I.S. certified devices in explosive atmospheres. Supports hazardous locations including Zone 0, Zone 1, and Class I Div 1. Discrete Input Functionality Accepts 24V DC dry contact signals from pushbuttons, limit switches, or level switches. Detects wiring faults such as open circuits or shorts when used with proper end-of-line resistors. Single-channel design ensures precise monitoring of individual devices. Hardware Specifications Feature Specification I/O Type Intrinsically Safe Discrete Input (DI) Input Signal 24V DC, Dry Contact Number of Channels 1 (Single-channel) Isolation Channel-to-system galvanic isolation Bus Power +6.3 VDC at 0 mA Field Circuit Power +24 VDC at 23 mA Environmental Protection ISA-S71.04 Class G3 Operating Temperature -40°C to +70°C Shock 10g, 11 ms, half-sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz) Terminal Keying E6 Operational Advantages Eliminates the need for external I.S. barriers, reducing control room and field enclosure footprint by 50–70%. Hot-swappable in compliance with hazardous area guidelines without affecting other modules. Supports DeltaV late binding, enabling any signal type to be landed on any terminal block without rewiring. Applications Field-mounted junction boxes for chemical, petrochemical, and oil & gas plants. Remote monitoring of switches, pushbuttons, and level devices in hazardous zones. Ideal for projects requiring flexible, modular I/O deployment. FAQ Q: Can the module be removed while system power is on?A: No, the KL3106X1-BA1 must only be inserted or removed with power off. Q: Does it require calibration?A: No calibration is necessary; the module is factory-calibrated and ready for operation. Q: Are external I.S. barriers required?A: No, the module’s built-in isolation and energy-limiting circuitry remove the need for separate barriers.
$200.00 $100.00
-
EMERSON Emerson DeltaV KL3105X1-BA1 I.S. Thermocouple Module | CHARM
Product Description Overview The Emerson DeltaV KL3105X1-BA1 is a precision Intrinsically Safe (I.S.) CHARM designed for DeltaV Electronic Marshalling systems. This module supports direct connection to temperature sensors and low-voltage signals in hazardous areas without requiring external I.S. barriers, simplifying installation while ensuring safety and measurement accuracy. Key Features Intrinsically Safe Integration Integrated galvanic isolation meets IECEx ia and ATEX requirements for Zone 0 / Class I, Div 1 environments. Eliminates external barrier cabinets, reducing wiring complexity and panel footprint. Supports installation in Zone 2/Class I Div 2 environments. Precision Measurement Compatible with Thermocouple types B, E, J, K, N, R, S, T. Accepts millivolt inputs from -100 mV to +100 mV. Internal cold junction compensation ensures accurate temperature readings. High-resolution ADC ensures stable and precise data acquisition. Diagnostics and Reliability Detects sensor faults, open circuits, and wiring issues. LED indicators: Green (normal), Blinking Red (field fault), Solid Red (module fault). Hot-swappable under appropriate hazardous area guidelines without interrupting other channels. Hardware Specifications Feature Specification Input Type Thermocouple / Millivolt (-100 mV to +100 mV) I/O Type Intrinsically Safe Analog Input Bus Power +6.3 VDC at 0 mA Field Circuit Power +24 VDC at 23 mA Operating Temperature -40°C to +70°C (-40°F to +158°F) Shock 10g, 11 ms, half-sine wave Vibration 1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz) Environmental ISA-S71.04 Class G3 Airborne Contaminants Terminal Block Keying Position C5 (prevents incorrect insertion) Applications Field-mounted junction boxes in hazardous zones. Temperature monitoring in chemical, petrochemical, and oil & gas plants. Systems requiring flexible, late-binding I/O configuration. FAQ Q: Can the module be removed while the system is powered?A: No, the module must be inserted or removed only with system power off. Q: Is calibration required for operation?A: No calibration is needed; the module is factory-calibrated. Q: Does the module support external I.S. barriers?A: No external barriers are required; the CHARM provides built-in isolation and energy-limiting circuitry.
$200.00 $100.00
-
EMERSON Emerson DeltaV KL3101X1-LS1 | S-Series 8-Channel Analog Input Module
Overview The Emerson DeltaV KL3101X1-LS1 is an 8-channel analog input card engineered for DeltaV Distributed Control Systems (DCS). It interfaces with field-mounted transmitters, capturing 4-20 mA signals and supporting HART communication for digital diagnostics and secondary variable monitoring. Part of the S-Series “Electronic Marshalling” hardware, this module combines high-density input, precision conversion, and robust industrial resilience. This module is designed for standard process control environments, providing reliable performance and seamless integration in high-density I/O cabinets. Technical Features HART Integration Supports digital pass-through of HART data alongside analog signals Enables device health monitoring and remote calibration via AMS Device Manager Facilitates predictive maintenance without additional wiring High-Density Design 8 analog inputs per card to maximize cabinet space Low power consumption for efficient thermal management Compact form factor simplifies installation and expansion Reliability and Protection Galvanic isolation safeguards controller electronics from field surges Conformal coating per ISA-71.04 Class G3 protects against dust, moisture, and corrosive atmospheres Built for continuous operation in harsh industrial environments Hot-Swappable Operation Allows module replacement without powering down the DeltaV system Ensures uninterrupted process control during maintenance or upgrades Technical Specifications Feature Specification Input Channels 8 Analog Channels Signal Type 4-20 mA DC HART Support Digital Pass-Through A/D Resolution 16-bit Sampling Interval 100 ms per 8 channels Accuracy ≤0.1% of Span Operating Temperature -40°C to 70°C (-40°F to 158°F) Protection Conformal coating G3, galvanic isolation Operational Advantages Simplifies wiring by eliminating external HART multiplexers Enhances proactive diagnostics for early detection of device faults Automatically recognized by DeltaV software, reducing commissioning time Supports flexible system expansion in S-Series hardware setups Applications Standard process control in chemical, pharmaceutical, and oil & gas industries High-density analog signal collection in DeltaV S-Series cabinets Remote monitoring and predictive maintenance using HART-enabled devices FAQ Q: Can the KL3101X1-LS1 be installed or removed while the system is running?A: Yes, it supports hot-swappable operation, allowing replacement without shutting down other system components. Q: Does the module require field calibration?A: No. The module is factory-calibrated and contains no user-serviceable parts. Q: Which DeltaV systems are compatible?A: Compatible with DeltaV S-Series controllers and carriers; verify system version before installation. Q: What environments can it operate in safely?A: Rated for standard industrial environments with temperature extremes from -40°C to 70°C and protection against dust and moisture (G3 conformal coating).
$200.00 $100.00
-
EMERSON Emerson DeltaV KL3102X1-BA1 | HART 4-20mA Analog Input Module
Module Overview The Emerson DeltaV KL3102X1-BA1 is an advanced 8-channel analog input module for DeltaV Distributed Control Systems. Designed for integration with field transmitters, it converts 4-20 mA analog signals into digital data for precise process control. The module supports HART communication, enabling device diagnostics and secondary variable monitoring without extra wiring. This module is ideal for process industries requiring reliable, real-time data acquisition and predictive maintenance through enhanced instrument communication. Technical Specifications Electrical Specifications Input Channels: 8 analog inputs Input Type: 4-20 mA DC, HART-enabled Field Power: +24 VDC at 56 mA Module Power: +6.3 VDC at 0 mA Isolation: Full galvanic isolation per channel Performance Features Bi-directional HART communication for device diagnostics High-resolution A/D conversion for precise measurements Digital filtering to reject 50/60 Hz EMI noise Fast sampling rates suitable for closed-loop process control Environmental Ratings Operating Temperature: -40°C to +70°C Shock Resistance: 10 g, 11 ms half-sine Vibration Tolerance: 1 mm peak-to-peak at 2–13.2 Hz, 0.7 g at 13.2–150 Hz Relative Humidity: 5–95% non-condensing Airborne Contaminants: ISA-S71.04 Class G3 Safety & Compliance ATEX/IECEx Certified for hazardous areas FM, CL I/II/III Division 1 & 2 rated Intrinsically safe operation per II 3G Ex ec [ia Ga] IIC Gc standards Operational Benefits Compact Design: High-density channel layout reduces cabinet footprint Maintenance Friendly: LED indicators display power, errors, and channel activity Environmental Resilience: Conformal coating protects against dust, moisture, and industrial contaminants Hot-Swappable Support: Replace modules without shutting down other system components Applications Process control systems in chemical, oil & gas, and pharmaceutical plants Instrumentation monitoring for pressure, temperature, flow, and level Facilities requiring predictive maintenance through HART-enabled devices FAQ Q: Can the KL3102X1-BA1 be replaced while the system is powered?A: No. The module must be removed or installed only with system power off to ensure safety and prevent damage. Q: Does this module require calibration?A: No user calibration is needed; the module is factory-calibrated and contains no serviceable parts. Q: Is this module compatible with DeltaV S-Series and M-Series?A: Yes. Confirm carrier and system version compatibility before installation. Q: What types of hazardous environments can it operate in?A: The module is certified for zones 1 and 2 (gas) and zones 21 and 22 (dust) under ATEX/IECEx standards.
$200.00 $100.00
-
EMERSON Emerson KL3103X1-BA1 DeltaV S-series 8-Channel Intrinsically Safe I/O Module
Product Description Overview The KL3103X1-BA1 is an intrinsically safe digital input and output CHARM module from Emerson, designed for DeltaV S-series Distributed Control Systems. This 8-channel module converts controller commands into 24V DC output to drive field devices such as solenoid valves, relays, and indicator lights, while providing full protection in hazardous environments. Its compact CHARM design allows seamless integration into modular I/O panels and ensures reliable operation in harsh industrial conditions. Technical Specifications Feature Specification Model KL3103X1-BA1 Module Type Intrinsically Safe Digital Output CHARM Channels 8 discrete outputs Output Voltage 24V DC Output Current 0.5 A per channel (typical) Output Type High-side switching Power Supply CHARM Bus: +6.3 VDC, 32 mA; Field: +24 VDC, ~10 mA Fault Detection Open/short circuit detection with LED and software alerts Safety Certifications ATEX, IECEx, FM, UKEX Hazardous Area Rating Zone 2 / Class I Division 2 / Groups A-D Terminal Block Key 2C Operating Temp. -40°C to +70°C Humidity 5–95% RH, non-condensing Shock & Vibration 10g half-sine, 11 ms; 1 mm peak-to-peak 2–13.2 Hz, 0.7g 13.2–150 Hz Weight 0.18 lbs Form Factor S-series CHARM module Applications Monitoring switches, pushbuttons, and contact closures in hazardous areas Field interface for solenoids and indicator lights in chemical, petrochemical, and oil & gas plants Remote intrinsically safe I/O panels for process control Integration with DeltaV systems for single-channel or multi-channel output configurations FAQ Q: Is this module safe for hazardous Zone 2 locations?A: Yes, it is intrinsically safe and certified for Zone 2 / Class I Division 2 environments. Q: How many devices can it monitor?A: Each module provides 8 discrete outputs; multiple modules can be installed for expanded control. Q: Does it require calibration?A: No calibration is necessary, and the module contains no user-serviceable parts. Q: Can the module be replaced while the system is powered?A: Yes, it is hot-swappable when installed in a keyed S-series carrier.
$200.00 $100.00
-
EMERSON Emerson KL3101X1-BA1 DeltaV S-series 8-Channel Dry Contact Input Module
Product Description Overview The KL3101X1-BA1 from Emerson is an 8-channel discrete input card designed for DeltaV S-series systems. It provides robust monitoring of field devices such as limit switches, pushbuttons, and relay contacts by converting physical contact closures into digital signals for the controller. Engineered for hazardous and standard industrial environments, it delivers reliable performance with minimal maintenance. Core Functions Discrete Signal Detection Monitors the open or closed state of 24V DC field circuits Provides internal sensing voltage for dry contact inputs, eliminating the need for external power Noise Filtering and Debouncing Configurable digital filtering ensures accurate readings without false triggering Maintains signal integrity in electrically noisy environments Rapid Response Optimized for low-latency input detection, essential for safety interlocks and high-speed automation sequences Safety and Compliance Certified for hazardous areas: ATEX, IECEx, FM, CSA, and CL1 DIV2 standards Designed for energy-limited applications to meet safety integrity levels Resistant to shock, vibration, and airborne contaminants per ISA-S71.04 Class G3 S-series Reliability Features Hot-swappable for replacement without system downtime Automatic identification by DeltaV controller upon insertion Continuous self-diagnostics to monitor internal health and functionality Technical Specifications Feature Specification Model KL3101X1-BA1 Input Channels 8 Discrete Inputs Input Type 24V DC, Dry Contact ON Detection Level > 2.5 mA typical OFF Detection Level < 1.0 mA typical Isolation Galvanic isolation between field and controller Power Requirements CHARM Bus: +6.3 VDC @ 0 mA; Field Circuit: +24 VDC @ 60 mA Operating Temperature -40°C to +70°C Shock & Vibration 10 g half-sine, 11 ms; 1 mm p-p 2–13.2 Hz, 0.7 g 13.2–150 Hz Humidity 5–95% Non-condensing Terminal Block Key A1 Mounting DeltaV S-series horizontal I/O carrier Maintenance No user-serviceable parts; calibration not required Applications This module is ideal for monitoring discrete field signals in chemical, oil & gas, power generation, and manufacturing plants. It supports sequence-of-events (SOE) recording when paired with compatible DeltaV controllers. FAQ Q: Can this card be installed while the system is powered?A: No, it must be inserted or removed only when system power is off to ensure safety. Q: Does the card require calibration?A: No calibration is necessary; the module is factory configured and maintenance-free. Q: What type of switches are supported?A: Designed for dry contact switches; internal 24V DC sensing voltage powers the field device. Q: Is it compatible with older M-series hardware?A: No, this module is optimized for S-series carriers only.
$200.00 $100.00
-
EMERSON Emerson KL3022X1-BA1 DeltaV S-series 8-Channel Analog Input Module
Product Description Overview The KL3022X1-BA1 from Emerson’s DeltaV S-series is an 8-channel analog input module designed for reliable, high-precision process control. It converts 4–20 mA signals from field instruments into digital data while supporting HART communication for device diagnostics and configuration. This module is engineered for demanding industrial environments and integrates seamlessly into DeltaV S-series I/O nodes. Key Features Signal Acquisition and Conversion Handles 8 independent 4–20 mA analog input channels Converts analog signals to 16-bit digital values with high accuracy Isolated channel design protects backplane from surges and ground loops HART Integration Supports HART versions 5, 6, and 7 Allows live diagnostics and instrument configuration without interrupting control Compatible with AMS Device Manager and similar asset management software S-series Hardware Advantages Hot-swappable within S-series I/O carriers for minimal downtime Compact form factor optimized for airflow and heat dissipation Terminal block keying ensures safe, compatible installation Operational Reliability Wide operating temperature: -40°C to +70°C Shock: 10 g, half-sine, 11 ms; vibration: 1 mm p-p at 2–13.2 Hz, 0.7 g at 13.2–150 Hz Relative humidity: 5–95%, non-condensing Resistant to airborne contaminants per ISA-S71.04 Class G3 Technical Specifications Specification Detail Model KL3022X1-BA1 Channels 8 Analog Inputs Signal Type 4–20 mA DC Input Impedance Typically 250 Ω Protocol Support HART v5, v6, v7 Resolution 16-bit ADC Power Requirements CHARM bus: +6.3 VDC @ 32 mA; Field circuits: +24 VDC @ 30 mA Operating Temperature -40°C to 70°C Shock & Vibration 10 g half-sine, 11 ms; 1 mm p-p 2–13.2 Hz, 0.7 g 13.2–150 Hz Mounting DeltaV S-series I/O carrier Maintenance No user serviceable parts; calibration not required Applications Ideal for process automation in chemical, oil & gas, power generation, and manufacturing plants where precise analog signal monitoring and HART device integration are critical. FAQ Q: Can this module be installed while the system is powered?A: Only in non-hazardous areas. Always perform an I/O loop energy assessment before installation or removal. Q: Does this module require calibration?A: No calibration is required. The module is factory calibrated and maintenance-free. Q: Can I use other CHARM types on the same terminal block?A: Yes, but terminal block keys must be reset to unlock compatibility. Q: Is this module compatible with older M-series I/O?A: No, it is designed specifically for S-series I/O carriers and hot-swap environments.
$200.00 $100.00
You have seen 168 out of 622 products