All Products
-
EMERSON Emerson DeltaV KJ3223X1-BK1 FM21UKEX0017U AI 16-Channel HART Module
Product Description Overview The KJ3223X1-BK1 AI 16-Channel 4–20mA HART Card from Emerson DeltaV is engineered for hazardous environments, providing precise analog input measurement and HART communication for advanced process control. This module supports Zone 2 and Class I Division 2 hazardous areas and offers robust electrical and environmental performance for reliable operation in industrial systems. Installation and Safety Notes Field power, either local or bussed, must be removed before installation or removal I/O loop assessment required for all energy-limited nodes before connection Module cannot be inserted or removed while system power is energized Rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed to the I/O card they serve Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts Disassembly is prohibited Calibration is not required Application Scenarios Ideal for high-density analog input measurement in hazardous zones, integrating 16 channels of 4–20 mA HART signals into DeltaV systems for chemical processing, energy, and oil & gas facilities. Frequently Asked Questions (FAQ) Q: Can this HART card be removed while the system is powered?A: No. Removal or installation requires the system to be powered down unless the area is non-hazardous. Q: Is calibration required for operation?A: No. The module does not require calibration and has no user-serviceable parts. Q: How does the keying system prevent installation errors?A: The rotary keying system ensures the terminal block is correctly matched to the corresponding I/O card. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Number of Channels 16 Signal Type 4–20 mA HART Operating Temperature -40 °C to +70 °C Shock 10 g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) by Emerson is designed for safe, reliable operation in hazardous areas. Supporting both Zone 2 and Class I Division 2 classifications, this device provides flexible I/O connectivity while complying with strict industrial safety standards. Its robust construction and advanced keying system ensure compatibility and secure operation in demanding process environments Installation and Safety Guidelines Field power (local or bussed) must be removed before connecting or removing the device Energy-limited nodes require an I/O loop assessment before installation The module cannot be installed or removed while the system is energized A rotary keying system ensures correct alignment between I/O cards and terminal blocks Terminal blocks must be keyed according to the I/O card in use Refer to documentation: 12P5404 “DeltaV™ Scalable Process System Zone 2 Installation Instructions” “DeltaV™ S-series and CHARMs Hardware Installation” manual Maintenance and Calibration No user-serviceable parts inside Disassembly is strictly prohibited Calibration is not required Application Scenarios The module is suitable for signal isolation and I/O integration in hazardous industrial areas such as chemical processing plants, oil & gas facilities, and energy production sites. Frequently Asked Questions (FAQ) Q: Can this module be removed while system power is on?A: No. It must only be removed or installed with power off, unless the area is verified non-hazardous. Q: Is calibration required for this module?A: No calibration is required; the device contains no user-serviceable parts. Q: How does the keying system work?A: A rotary keying system ensures the terminal block matches the corresponding I/O card after installation, preventing misalignment. Technical Specifications Parameter Specification Certifications II 3G Ex nA [nL] IIC Gc, II 3G Ex ec [ic] IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec [ic] IIC Gc Local Bus Power 12 VDC, 150 mA Bussed Field Power 24 VDC, 600 mA Field Circuit 24 VDC, 30 mA per channel Operating Temperature -40 °C to +70 °C Shock 10g, half-sine, 11 ms Vibration 1 mm peak-to-peak 2–13.2 Hz; 0.7 g 13.2–150 Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Terminal Block Key Position A2 Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KL1604X1-BA1 FM21UKEX0017U Safety Isolation Port
Product Description Overview The KL1604X1-BA1 Safety Isolation Port (Copper) from Emerson DeltaV is a high-reliability field device designed for hazardous areas. Engineered to meet stringent Zone 2 and Class I Division 2 requirements, this module ensures safe and stable signal isolation in challenging industrial environments, including chemical plants, refineries, and energy facilities. Certifications and Hazardous Area Ratings Explosion-proof certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Suitable for hazardous atmospheres with combustible gases Installation and Safety Notes Only install or remove the device with system power off unless in a non-hazardous area Follow the DeltaV™ documentation: 12P5403 “DeltaV Electronic Marshalling Digital Automation System (CHARM I/O Subsystem) Zone 2 Installation Instructions” “DeltaV S-series and CHARMs Hardware Installation” manual Maintenance and Calibration Contains no user-serviceable components Disassembly is prohibited Calibration is not required Application Scenarios Ideal for signal isolation in hazardous zones within process automation systems, including chemical processing, oil and gas facilities, and industrial energy management. Frequently Asked Questions (FAQ) Q: Can the module be removed or inserted while system power is on?A: No. Safe operation requires power to be off unless the area is confirmed non-hazardous. Q: Is calibration needed for this unit?A: No calibration is required, and no user-serviceable parts are present. Q: What type of signal isolation does this port provide?A: It ensures reliable galvanic isolation of field signals, protecting both the system and personnel in hazardous environments.
$200.00 $100.00
-
EMERSON DeltaV S-Series FM21UKEX0017U Hazardous Area I/O Module
Product Description Overview The DeltaV S-Series Module (FM21UKEX0017U) is a high-reliability I/O device engineered for hazardous environments. It supports Zone 2 and Class I Division 2 areas, meeting stringent explosion-proof and industrial standards. This module is ideal for automation systems in chemical, petrochemical, and energy industries. Certifications and Protection Explosion Protection Certifications: II 3G Ex ec IIC Gc (FM19ATEX0173U / IECEx FMG 19.0019U) II 3G Ex nA nL IIC Gc (Nemko 10ATEX3225U / IECEx NEM 10.0019U) Class I Division 2, Groups A, B, C, D Class I Zone 2 AEx/Ex ec IIC Gc (FM17US0286U / FM17CA0145U) Environmental Rating: Operates reliably from -40°C to +70°C Shock and Vibration Resistance: Shock: 10g, half-sine, 11ms Vibration: 1mm peak-to-peak from 2–13.2Hz; 0.7g from 13.2–150Hz Power and Connectivity Local bus power: 12 VDC, 160 mA Terminal block supports rotary keying to ensure correct I/O card matching Device installation/removal requires system power to be turned off; “nL” installation requires energy-limited node assessment Environmental Tolerance Airborne contaminants: ISA-S71.04 Class G3 Relative humidity: 5–95%, non-condensing No user-serviceable parts; calibration not required Application Scenarios Suitable for strictly controlled hazardous industrial locations, including chemical processing plants, refineries, natural gas facilities, and power stations. Frequently Asked Questions (FAQ) Q: Can the module be inserted or removed while system power is on?A: No. The module must only be handled with the system powered down. Q: Is periodic calibration required?A: No. The device contains no user-serviceable parts and does not require calibration. Q: How is terminal block and I/O card compatibility ensured?A: The rotary keying system automatically aligns terminal blocks with the corresponding I/O cards after installation. Technical Specifications Parameter Specification Certifications II 3G Ex ec IIC Gc, II 3G Ex nA nL IIC Gc, Class I Div.2 GP. A,B,C,D, Class I Zone 2 AEx/Ex ec IIC Gc Power Local bus 12 VDC, 160 mA Operating Temperature -40°C to +70°C Shock 10g, half-sine, 11ms Vibration 1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz Airborne Contaminants ISA-S71.04 Class G3 Relative Humidity 5–95%, non-condensing Maintenance No user-serviceable parts; calibration not required
$200.00 $100.00
-
EMERSON DeltaV M-Series FM17US0286U Emerson Zone 2 Hazardous Controller
Product Description Overview The DeltaV M-Series (FM17US0286U) from Emerson is engineered for safe operation in hazardous environments, meeting international standards for explosive atmospheres. Designed for Zone 2/Division 2 applications, it ensures reliable process control with minimal maintenance requirements. Certifications & Hazardous Area Ratings II 3G Ex ec IIC Gc – ATEX Certified (FM16ATEX0056U / FM21UKEX0017U) Class I Division 2 Groups A, B, C, D – North American Standards Zone 2 AEx/Ex ec IIC Gc – IECEx Certified (FM17US0286U / FM17CA0145U) These ratings confirm suitability for environments with flammable gases, vapors, and dust, providing safe operation under strict regulatory requirements. Electrical & Power Specifications Local Bus Power: 12.6 VDC at 8 A Power must be de-energized before any module removal or connection changes Supports system operation under full-rated power within hazardous area limits Installation & Maintenance Follow DeltaV™ Scalable Process System Zone 2 Installation Instructions (Document 12P2046) System power must be off during insertion or removal of modules in hazardous areas Non-serviceable; do not disassemble No calibration required for standard operation Applications Ideal for process industries requiring reliable distributed control in hazardous environments, such as: chemical, oil & gas, and refining sectors. Supports integration into scalable DeltaV systems for automated process monitoring and control. FAQ Q: Can this module be inserted with power on?A: No. Insertion or removal must occur only in a non-hazardous, de-energized state. Q: Does this unit require periodic calibration?A: No calibration is needed. The unit is factory-configured for operation within specified parameters. Q: How does it differ from FM16ATEX0056U?A: FM17US0286U is designed for US and Canadian hazardous area certifications with Zone 2/Div. 2 compliance, while FM16ATEX0056U focuses on ATEX Zone 2 certification. Technical Specifications Table Specification Value Operating Temp -40°C to +70°C Shock 10 g, ½ sinewave, 11 ms Vibration 1 mm P-P (2–13.2 Hz), 0.7 g (13.2–150 Hz) Humidity 5–95% Non-Condensing Airborne Contaminants ISA-S71.04 Class G3 Local Bus Power 12.6 VDC at 8 A Hazardous Area Rating II 3G Ex ec IIC Gc, Class I Div 2, Zone 2 AEx/Ex ec IIC Gc Maintenance No user-serviceable parts, calibration not required
$200.00 $100.00
-
EMERSON Emerson DeltaV KJ2101X1-BA1 Horizontal 2-Slot Controller Carrier
Product Description Overview The Emerson KJ2101X1-BA1 is a Horizontal 2-Slot Controller Carrier designed for DeltaV Distributed Control Systems (DCS). It provides a robust and reliable mounting and electrical interface for controllers and power supplies. The carrier ensures seamless communication between DeltaV controllers and I/O subsystems, while simplifying power distribution and cabinet wiring. Its compact, DIN-rail mountable design supports both single and redundant controller configurations. Key Technical Features Controller Redundancy Support: Enables failover operation with two controllers installed, maintaining continuous process control during a failure. Integrated Power Management: Distributes 24 VDC from the power supply to the controller and I/O bus, reducing cabling complexity. High Signal Integrity: Backplane design minimizes electrical noise, ensuring stable communication between controller and modules. Hot-Swap Capability: Supports insertion and removal of controllers or power supplies without shutting down the system, following proper safety procedures. Industrial Reliability: Optional G3 conformal coating protects against corrosion from airborne chemical contaminants. Passive Backplane Design: No active electronics on the carrier, providing extremely high MTBF. Technical Specifications Feature Specification Slot Capacity 2 slots (Controller / Power Supply or dual controllers for redundancy) Mounting Horizontal DIN-rail (T-type) Input Power 24 VDC nominal Local Bus Current Up to 8 A per carrier depending on load configuration Operating Temperature -40°C to 70°C (-40°F to 158°F) Environmental Rating ISA-S71.04-1985, Airborne Contaminants Class G3 Physical Dimensions Width: 2 slots (~3.5 in), Height: 3.5 in, Depth: 6 in (approx.) Weight ~0.5 kg Primary Benefits Space-Efficient Layout: Compact horizontal design for optimized cabinet use. Error Reduction: Keyed slots and clear labeling prevent incorrect module installation. Expandable System Architecture: Easily integrates with additional carriers and controllers via local bus cabling. Applications Centralized control in process plants Redundant controller configurations for critical operations Integration with DeltaV MD and MQ series controllers Harsh industrial environments requiring corrosion-resistant backplanes FAQ Q: Can the KJ2101X1-BA1 support two controllers simultaneously?A: Yes, it supports dual-controller setups for redundancy, allowing seamless failover operation. Q: Is hot-swapping safe on this carrier?A: Yes, controllers or power supplies can be replaced without system shutdown, provided standard safety procedures are followed. Q: What is the maximum local bus current supported?A: Up to 8 A, depending on the configuration of installed modules. Q: Are there similar carriers for different slot configurations?A: Yes, Emerson offers 1-wide and 3-wide carriers for various system sizes and redundancy requirements.
$200.00 $100.00
-
EMERSON Emerson KJ4110X1-EB1 IS Localbus Isolator Module DeltaV I/O
Product Description Overview The Emerson KJ4110X1-EB1 is an intrinsically safe (IS) Localbus Isolator Module designed for hazardous industrial environments. It provides robust isolation and reliable signal integrity within Emerson’s DeltaV IS I/O systems. Engineered for critical process applications, it safeguards equipment and personnel while maintaining high uptime in demanding process control installations. Key Features Intrinsically Safe Design: Certified for operation in Class I, Division 1, Zone 0 and Zone 1 hazardous areas. Redundant Power Architecture: Supports high-availability systems for continuous operation. DIN Rail Mountable: Simplifies installation within standard control cabinets. Status Indicators: Integrated LEDs provide clear module health and operational status. Wide Environmental Tolerance: Operates reliably in extreme temperatures and high-humidity conditions. Shock and Vibration Resistance: Meets industrial IEC and ISA standards for rugged environments. Technical Specifications Feature Specification Model Intrinsically Safe Localbus Isolator Module Part Number KJ4110X1-EB1 Manufacturer Emerson System Compatibility DeltaV IS I/O Modules Mounting Type DIN Rail LED Indicators Yes Maximum Current 60 Amps Power Supply Redundant architecture for reliability Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Installation Temperature 0°C to +60°C Relative Humidity 5%–95%, non-condensing Shock Resistance 10g, half-sine wave, 1 ms Vibration Resistance 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz) Hazardous Area Ratings Class I Division 1, Zone 0/1 compliant Weight 0.73 lbs Applications Hazardous area signal isolation for DeltaV IS I/O systems Critical process control installations requiring high uptime Integration with intrinsically safe field devices in chemical, petrochemical, and energy sectors FAQ Q: Can this module be used outside hazardous areas?A: Yes, it functions normally in non-hazardous environments but is certified for IS applications. Q: Does it support redundant power supplies?A: Yes, it includes a redundant power architecture for high-reliability operation. Q: What I/O systems are compatible?A: Compatible with DeltaV IS Localbus I/O modules. Q: How is it mounted?A: Standard DIN rail mounting simplifies installation in control panels.
$200.00 $100.00
-
EMERSON Emerson DeltaV VE4002S1T2B5 MD Plus Controller High-Reliability DCS
Product Description Overview The Emerson DeltaV VE4002S1T2B5 is a high-performance MD Plus Controller engineered for distributed control systems. Designed for demanding industrial environments, this controller executes real-time process logic, manages local I/O, and provides seamless communication with the DeltaV network. It is optimized for complex process control, batch sequences, and advanced mathematical computations, ensuring deterministic performance with minimal latency. Technical Specifications Feature Specification Model MD Plus Controller Part Number VE4002S1T2B5 Input Power 24 VDC via 2-wide DeltaV Carrier Operating Temperature -40 to 70 °C (-40 to 158 °F) Storage Temperature -40 to 85 °C (-40 to 185 °F) Relative Humidity 5–95%, non-condensing Vibration/Shock Meets IEC 60068 and ISA-S71.04 standards Redundancy Support 1:1 Controller Redundancy with Zero Bumpless Transfer Mounting DeltaV 2-wide Controller Carrier I/O Compatibility Traditional, HART, Foundation Fieldbus Memory Expanded for large configuration databases Execution Real-time local logic processing, alarm handling, and data polling Applications Continuous process control Batch processing and recipe management Critical industrial processes requiring high availability Integration with advanced process automation strategies Maintenance and Reliability The VE4002S1T2B5 supports hot-swapping, enabling replacement or upgrades without system shutdown. Its high MTBF and robust industrial design ensure reliable operation in extreme environments, including temperature fluctuations, vibration, and humidity variations. FAQ Q: Can the VE4002S1T2B5 operate independently of the DeltaV workstation?A: Yes, once the configuration is loaded, it runs autonomously, managing local I/O and alarms. Q: Does it support redundant operation?A: Yes, it allows 1:1 redundancy with seamless failover, ensuring uninterrupted process control. Q: What types of I/O are supported?A: Compatible with traditional, HART, and Foundation Fieldbus I/O devices. Q: Can it be mounted on other carrier sizes?A: No, it is designed specifically for the DeltaV 2-wide controller carrier.
$200.00 $100.00
-
EMERSON DeltaV VE4003S2B 18-Channel I/O Termination Block 4-20mA HART
Product Description OverviewThe VE4003S2B from DeltaV is an 18-channel Standard I/O Termination Block engineered for precise signal management in 4-20 mA HART systems. Designed to provide reliable signal termination and robust communication integrity, it ensures stable operation across harsh industrial environments. Its rugged design supports wide operating and storage temperature ranges, high humidity tolerance, and resistance to vibration and airborne contaminants. Key Features 18 channels for 4-20 mA HART signals Standard I/O termination for seamless DeltaV integration High-temperature tolerance: operates from -40°C to +70°C and stores safely up to 85°C Humidity range: 5% to 95% non-condensing Airborne contaminant resistance: ISA-S71.04-1985 Class G3 with conformal coating Shock-resistant design: withstands 10 g half-sine wave for 11 ms Protection rating: IP20 for safe indoor installations Compact and robust: Approx. 10.7 cm × 4.1 cm × 10.5 cm Shipping weight: 1.5 kg Available for same-day shipping Technical Specifications Parameter Specification Product Type Standard I/O Termination Block Manufacturer DeltaV Model Number VE4003S2B Channels 18 x 4-20 mA HART Operating Temperature -40°C to +70°C (-40°F to 158°F) Storage Temperature -40°C to +85°C (-40°F to 185°F) Relative Humidity 5% to 95%, non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3, conformal coated Protection Rating IP20 Shock Resistance 10 g, half-sine wave, 11 ms Dimensions (HxWxD) 10.7 cm × 4.1 cm × 10.5 cm Shipping Weight 1.5 kg ApplicationsThe VE4003S2B is ideal for distributed control systems requiring precise analog signal management. Common use cases include process control in chemical plants, oil and gas facilities, and manufacturing systems where HART-enabled devices transmit critical analog and digital signals. FAQQ: Can this I/O termination block operate in extreme cold environments?A: Yes, it functions reliably down to -40°C. Q: Is the VE4003S2B suitable for high-humidity conditions?A: Yes, it tolerates 5% to 95% relative humidity without condensation. Q: How resistant is the device to industrial vibrations or shocks?A: The block is rated for 10 g shock resistance with an 11 ms half-sine waveform. Comparison with Similar ModelsCompared to the VE4002S2B, the VE4003S2B provides additional channels and HART signal support, offering greater flexibility for medium to large-scale DeltaV installations.
$200.00 $100.00
-
EMERSON Emerson VE4070 Local Bus Isolator and Carrier for DeltaV
Product Description OverviewThe VE4070 from Emerson is a Local Bus Isolator and Carrier designed to enhance signal integrity and reliability within DeltaV control systems. This device provides robust isolation between network segments, minimizing communication disruptions in critical industrial environments. Its compact form factor allows seamless integration into existing DeltaV setups, ensuring uninterrupted operations and improved system stability. Key Features Isolates DeltaV Local Bus segments to prevent signal interference Boosts communication reliability for critical process control applications Compact and lightweight for flexible installation Fully compatible with DeltaV control system environments IP20 protection rating for safe operation in controlled indoor settings Shock-resistant design to withstand industrial vibration and impact Technical Specifications Parameter Specification Product Type Local Bus Isolator and Carrier Manufacturer Emerson Model Number VE4070 Dimensions (HxWxD) 16.5 cm × 8.4 cm × 3.1 cm (6.5 in × 3.3 in × 1.2 in) Weight 250 g Relative Humidity 5% to 95%, non-condensing Airborne Contaminants ISA-S71.04-1985 Class G3 Protection Rating IP20 Shock Resistance Withstands 10 g half-sine wave for 11 ms ApplicationsThe VE4070 is commonly deployed in distributed control systems (DCS) and industrial automation networks where maintaining network integrity and minimizing communication errors are critical. Typical uses include chemical plants, oil and gas facilities, power generation, and manufacturing process control. FAQQ: Can the VE4070 operate in environments with high humidity?A: Yes, it supports relative humidity from 5% to 95% non-condensing. Q: Does this device support outdoor installation?A: No, it has an IP20 rating suitable for indoor use only. Q: Can VE4070 handle vibration and mechanical shocks?A: Yes, it is engineered to withstand shocks up to 10 g for 11 ms, making it suitable for industrial conditions. Comparison with Similar ModelsCompared to the VE4071, the VE4070 offers a more compact design for installations with space constraints while maintaining the same level of isolation performance and DeltaV compatibility.
$200.00 $100.00
-
EMERSON DeltaV VE6050-RM100-24TX 24-Port Smart Ethernet Switch
Product Description OverviewThe VE6050-RM100-24TX is a high-performance 24-port smart Ethernet switch designed for industrial and automation networks. It provides versatile connectivity with both copper and fiber options while supporting advanced network diagnostics and cybersecurity features. Suitable for DIN rail or standard 19-inch rack installations, it combines reliability, efficiency, and scalability in a compact form factor. Key Features 24x 10/100BASE-TX RJ45 ports for standard Ethernet devices Two uplink ports supporting 10/100/1000 Mbps over copper or SFP fiber Two slots for VE6050-series transceiver modules for flexible fiber connections DeltaV-native management for seamless integration with Emerson automation systems Automatic network lockdown to enhance cybersecurity and prevent unauthorized access Flexible mounting: DIN rail or 19-inch rack Operating temperature: 0°C to +60°C (extended range -40°C to +70°C with conformal coating) Power input: 24V DC nominal (range 18–32V DC), maximum power consumption ≤30W Technical Specifications Parameter Specification Port Count 24x 10/100 Mbps RJ45 Uplink Ports 2x 10/100/1000 Mbps (Copper or SFP Fiber) Switching Capacity 12.8 Gbps Forwarding Rate 9.5 Mpps MAC Address Table 8K entries Standards Supported IEEE 802.3, 802.3u, 802.3ab, 802.1Q, 802.1D, 802.1w (RSTP) Management DeltaV Embedded, Web UI, SNMP Power Consumption ≤30W MTBF >300,000 hours Dimensions 440 mm × 300 mm × 44 mm (19-inch rack version) Environmental Operating: 0°C to +60°C, Extended: -40°C to +70°C with conformal coat Mounting DIN rail or 19-inch rack ApplicationsThe VE6050-RM100-24TX is ideal for industrial automation, process control networks, and environments requiring secure, high-availability Ethernet connectivity. Typical deployments include manufacturing plants, power distribution networks, and distributed control systems (DCS). FAQQ: Can this switch support gigabit connections on all ports?A: No, only the two uplink ports support 10/100/1000 Mbps. The 24 main ports are 10/100 Mbps. Q: Is it possible to extend the operating temperature for harsh environments?A: Yes, with the optional conformal coating, it can operate from -40°C to +70°C. Q: What management options are available?A: The switch supports DeltaV embedded management, SNMP, and web-based UI configuration. Comparison with Similar ModelsCompared to the VE6050-RM100-16TX, this model provides additional uplink capacity and expanded MAC address table support, making it suitable for larger industrial networks.
$200.00 $100.00
-
EMERSON Emerson KL2101X1-BB1 SE6504 CHARM I/O Card | Redundant CIOC2
Product Description OverviewThe Emerson KL2101X1-BB1 (SE6504) is a high-performance CHARM I/O Card designed for redundant CIOC2 configurations. Supplied as a pair, this module enhances system reliability and seamless integration within standard control cabinets. With robust protection, low power consumption, and user-configurable memory, it ensures consistent operation in demanding industrial environments. Key Features Supplied as a redundant pair for improved system reliability Compatible with standard cabinets and DeltaV systems Compact dimensions: 4.1 × 12.8 × 12.8 cm IP65 front protection for dust and water resistance Supports 256 kB of user memory for configuration and data logging Low active power consumption of 6 W typical Supports 4 blue-level display colors on a 5.7-inch micro TP screen Technical Specifications Parameter Specification Model Number KL2101X1-BB1 Alternate Part Number SE6504 Product Type CHARM I/O Card Package Original packaging Condition 100% Original, Brand New Screen Diagonal 5.7 in Number of Colors 4 (Blue Levels) MTBF Backlighting 50,000 h at 25°C Rated Current 0.24 A Starting Current Inrush 0.5 A²·s Active Power Input 6 W typical Memory Available for User Data 256 kB IP Rating IP65 (front) Operating Temperature 0°C to +50°C Storage Temperature -40°C to +85°C Weight 0.25 kg Shipping UPS, DHL, TNT, EMS Payment T/T (Bank Transfer) Warranty 12 months Service One-Stop Service ApplicationsDesigned for critical control systems, the KL2101X1-BB1 CHARM I/O Card is ideal for redundant CIOC2 configurations, industrial automation, monitoring, and data acquisition applications. Its compact design and high protection rating allow installation in standard cabinets without compromising reliability. FAQ Q: Can these I/O cards operate in harsh environments?A: Yes, the front panel is IP65-rated, and the cards operate between 0°C and 50°C, with storage up to 85°C. Q: How much user data memory is available?A: Each card provides 256 kB of memory for configuration and data logging. Q: Are these cards compatible with standard cabinets?A: Yes, they are designed to fit standard cabinets in redundant CIOC2 setups. Similar Models Comparison KL2101X2-BB2: Extended memory version for larger configurations KL2101X1-BC1: Single card variant for simplex systems
$200.00 $100.00
-
EMERSON Emerson Redundant Ethernet I/O Card Assembly | Dual EIOC Module
Product Description OverviewThe Emerson Redundant Ethernet I/O Card (EIOC) Assembly provides high-performance network connectivity and redundant operation for critical control systems. This assembly includes two EIOC cards, a dual horizontal carrier, two Ethernet isolation ports for twisted copper, and two power plugs, ensuring seamless integration and reliable data communication. It is ideal for systems requiring high availability and robust Ethernet I/O connectivity. Key Features Redundant and simplex configurations for system resilience Dual horizontal carrier for modular installation Ethernet isolation ports support twisted copper cabling Compatible with Modbus TCP, EtherNet/IP, IEC61850 MMS, and OPC UA Client protocols Supports up to 256 Ethernet devices and 32,000 signals from connected devices IP30 protection for enhanced electrical safety Fits one or two slots on a dual universal carrier Technical Specifications Parameter Specification Model Redundant Ethernet I/O Card (EIOC) Assembly Input Power (Simplex) 325 mA maximum Input Power (Redundant) 575 mA maximum Supply Voltage +24 VDC ±10% Heat Dissipation (Simplex) 7 W maximum Heat Dissipation (Redundant) 13 W maximum Communication Protocols Modbus TCP, EtherNet/IP, IEC61850 MMS, OPC UA Client Maximum Devices Supported 256 Ethernet devices Maximum Signals Supported 32,000 signals Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Relative Humidity 5%–95%, non-condensing Shock Resistance 10 g, half-sine wave, 11 ms Vibration Resistance 1 mm peak-to-peak (5–13.2 Hz), 0.7 g (13.2–150 Hz) Mounting One or two slots on Dual Universal Carrier Protection Class IP30 ApplicationsDesigned for high-availability control networks, the assembly is suitable for process control, monitoring, and distributed automation systems. Redundant operation ensures continuous data flow and reduces downtime during maintenance or fault conditions. FAQ Q: How many devices can this EIOC assembly support?A: The assembly can support up to 256 Ethernet devices and 32,000 signals from connected devices. Q: Can the system operate if one card fails?A: Yes, redundant configuration ensures continuous operation even if one EIOC card fails. Q: What protocols are supported for communication?A: Modbus TCP, EtherNet/IP, IEC61850 MMS, and OPC UA Client are fully supported. Similar Models Comparison Single EIOC Assembly: Supports simplex operation for smaller systems Extended Redundant EIOC: Provides additional slots and device capacity for larger installations
$200.00 $100.00
-
EMERSON SE3051C0 DeltaV 2-Wide Power/Controller Carrier for Emerson
Product Description OverviewThe Emerson SE3051C0 2-Wide Power/Controller Carrier is part of the DeltaV S-series, engineered for enhanced reliability, simplified assembly, and scalable control system expansion. Its modular architecture allows users to install only the capacity needed and expand online later by adding plug-and-play carriers. Integrated field power distribution reduces wiring complexity and improves system robustness. Key Features Supports two-wide controller modules for flexible configuration Modular design enables incremental system expansion Simplified power distribution with integrated backplane and fused bus connections Compatible with DeltaV S-series systems T-type DIN rail mounting for easy installation IP20 protection rating Technical Specifications Parameter Specification Model Number SE3051C0 Product Type 2-Wide Power/Controller Carrier System Compatibility DeltaV S-series Mounting Type T-type DIN rail Protection Rating IP20 Weight 0.99 lbs Primary/Secondary Power Supply 24 VDC Backplane Current 15 A Power Terminal Plug 12 A Power Bus Plug (Fused) 5 A Max Load per Bus 12 A Max Load per Card 3 A Controller Slot Capacity Supports 2-wide modules I/O Module Capacity Up to 8 I/O modules Operating Temperature -40°C to +70°C (-40°F to +158°F) Storage Temperature -40°C to +85°C (-40°F to +185°F) Relative Humidity 5%–95%, non-condensing Shock Resistance 10 g, 11 ms half-sine Vibration Resistance 1 mm peak-to-peak (5–13.2 Hz), 0.7 g (13.2–150 Hz) ApplicationsDesigned for critical DeltaV S-series installations, the SE3051C0 carrier simplifies cabinet assembly, streamlines power distribution, and allows flexible expansion for process control, monitoring, and automation networks. FAQ Q: How many I/O modules can this carrier support?A: It supports up to 8 I/O modules depending on the controller configuration. Q: Can I expand my system without shutting down operations?A: Yes, the modular plug-and-play design allows online addition of carriers and modules. Q: What is the maximum load per card?A: Each card can handle up to 3 A. Similar Models Comparison SE3050C0: Single-wide carrier for smaller configurations SE3052C0: Extended 3-wide carrier supporting more I/O and controllers
$200.00 $100.00
-
EMERSON Emerson KJ1501X1-BK1 SE5009 Power Supply Module | Industrial
Product Description OverviewThe Emerson KJ1501X1-BK1 (SE5009) is a dual DC power supply module designed for the DeltaV system, delivering reliable and stable power in demanding industrial environments. Built for both standard and hazardous locations (ATEx certified), it supports critical automation and control applications with high efficiency and durability. Key Features Dual DC output configuration for redundancy and reliability ATEx-compliant version available for hazardous areas Compatible with Emerson DeltaV automation systems Compact and robust design suitable for panel and cabinet installation Technical Specifications Parameter Specification Input Voltage 85–265 VAC Rated Output Power 1500 W Output Voltage 24 VDC Efficiency >90% Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Relative Humidity 5%–95%, non-condensing Dimensions 220 mm × 200 mm × 80 mm Weight 1.0 kg Origin USA ApplicationsIdeal for power-critical industrial automation systems, including DeltaV control networks, process monitoring, and control cabinets. Suitable for both standard and hazardous zone installations. FAQ Q: Can this module operate in high-temperature environments?A: Yes, the module supports operating temperatures from -40°C to +70°C. Q: Is the KJ1501X1-BK1 suitable for hazardous areas?A: Yes, an ATEx-certified version is available for explosive atmospheres. Q: Can it support redundant operation?A: Yes, its dual DC output design allows redundancy for critical systems. Similar Models Comparison KJ1502X1: Higher output power for larger DeltaV cabinets KJ1500X1: Standard 24 VDC single-output module for basic installations
$200.00 $100.00
-
EMERSON Emerson DeltaV DST1500 SX/Q Controller | Process Automation
Product Description OverviewThe DeltaV SX/Q Controller (DST1500) by Emerson delivers reliable control and communication for complex process environments. Engineered for seamless integration with field devices and other nodes across the control network, it provides flexible configurations to match controller capacity with process demands. Its design simplifies installation, eliminating the need for mounting hardware and accelerating cabinet assembly. Key Features Supports up to 1,500 DST limits Handles 3,200 SCADA tags Maximum data throughput: 4,000 values/sec sent, 500 values/sec received Supports up to 120 unsolicited client nodes Configurable module execution rates: 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 30 s, 60 s User memory: 96 MB Electrical Specifications Internal fuse protection: 3.0 A, non-replaceable Typical power consumption: 5 W Maximum power consumption: 7 W Environmental Specifications Operating temperature: -40°C to 60°C (-40°F to 140°F) Storage temperature: -40°C to 85°C (-40°F to 185°F) Relative humidity: 5% to 95%, non-condensing Shock resistance: 10 g, 11 ms half-sine Vibration tolerance: 1 mm peak-to-peak from 2–13.2 Hz, 0.7 g from 13.2–150 Hz ApplicationsIdeal for chemical, oil & gas, power, and manufacturing plants requiring precise process control and high-speed data communication. Suitable for systems demanding modular scalability and quick deployment. FAQ Q: Can the DST1500 handle multiple field device types simultaneously?A: Yes, it supports diverse field device protocols and integrates seamlessly with existing network nodes. Q: What module execution rate should I choose?A: Rates depend on process requirements; faster cycles (100–500 ms) are ideal for real-time monitoring, while slower cycles (1–60 s) suit routine process updates. Q: Is user memory expandable?A: The controller includes 96 MB of internal memory, sufficient for most SCADA and process automation tasks. Similar Models Comparison SX Controller: Optimized for small-to-medium process systems Q Controller: Offers higher capacity and extended I/O support for larger installations
$200.00 $100.00
-
EMERSON EMERSON SE4302T02 DeltaV DO 24V DC Isolated CHARM Module
Product Description Overview The SE4302T02 from EMERSON DeltaV™ is a digital output (DO) CHARM module engineered for 24 V DC inductive load control. Designed for installation directly in the field, it eliminates the need for traditional marshalling cabinets and complex cross-wiring, reducing installation time, wiring points, and potential failure risks. Its isolated output channels provide reliable performance while protecting downstream circuits. Key Features Supports 24 V DC inductive loads with 1.0 A continuous output and 2.0 A inrush for under 100 ms Configurable output behavior: momentary output or continuous pulse Galvanically isolated output channel, factory-tested to 1000 V DC Built-in field circuit protection: 4 A current limiting with thermal shutdown and automatic reset Recommended external fuse at power source for additional safety CHARM power requirement: 22 mA max @ 24 V DC Heat dissipation: 0.46 W Direct field installation minimizes wiring and eliminates the need for marshalling cabinets Technical Specifications Specification Details Model / Part Number SE4302T02 Device Type 24 V DC Inductive Load CHARM Output Voltage Range 4 V DC to 32 V DC Continuous Output Current 1.0 A Inrush Current 2.0 A (<100 ms) Off-State Leakage Current ≤1 mA Output Behavior Configurable: Momentary or Continuous Pulse Isolation Galvanically isolated, factory-tested to 1000 V DC Field Circuit Protection 4 A current limiting, thermal shutoff, automatic reset Recommended Protection External fuse at power source CHARM Power Requirement 22 mA max @ 24 V DC Heat Dissipation 0.46 W Installation Field-mountable, eliminates marshalling cabinets Applications Ideal for chemical, power generation, and oil & gas industries where space-saving, field-mounted I/O and reliable inductive load control are critical. The module simplifies wiring, reduces contact points, and enhances system reliability. FAQ Q: Can this module be used without a marshalling cabinet?A: Yes, the SE4302T02 is designed for direct field installation, removing the need for a traditional marshalling cabinet. Q: How is the output protected against overloads?A: Built-in 4 A current limiting with thermal shutoff protects the module, while an external fuse is recommended at the power source. Q: What output behaviors are configurable?A: Outputs can be configured as momentary pulses or continuous pulses depending on the application requirements.
$200.00 $100.00
-
EMERSON EMERSON SE4304T01 DeltaV DO 24V DC Isolated CHARM Module
Product Description Overview The SE4304T01 by EMERSON is a DeltaV digital output (DO) CHARM module designed for 24 V DC inductive load control. It provides reliable, isolated output channels with configurable behavior for both momentary and continuous pulse operations. Its built-in protections and galvanic isolation ensure safe, durable performance in demanding industrial environments. Key Features Supports 24 V DC inductive loads with continuous 1.0 A output and 2.0 A inrush for short periods (<100 ms) Output voltage range: 4 V DC to 32 V DC Galvanically isolated output channel, factory-tested to 1000 V DC for maximum signal integrity Configurable output behavior: momentary output or continuous pulse output Integrated field circuit protection: 4 A current limiting with thermal shutdown and automatic reset Recommended external fuse at power source for additional safety Low CHARM power consumption: 22 mA max at 24 V DC Minimal heat dissipation: 0.46 W Technical Specifications Specification Details Model / Part Number SE4304T01 Device Type 24 V DC Inductive Load CHARM Output Voltage Range 4 V DC to 32 V DC Continuous Output Current 1.0 A Inrush Current 2.0 A (<100 ms) Off-State Leakage Current ≤1 mA Output Behavior Configurable: Momentary or Continuous Pulse Isolation Galvanically isolated, 1000 V DC factory-tested Field Circuit Protection 4 A current limiting, thermal shutdown, automatic reset Recommended Protection External fuse at power source CHARM Power Requirement 22 mA max @ 24 V DC Heat Dissipation 0.46 W Applications Designed for industrial systems requiring precise, isolated digital outputs. Common applications include process control, chemical plants, oil & gas operations, and power generation systems where inductive load management and output protection are essential. FAQ Q: What is the maximum continuous output current?A: The SE4304T01 supports 1.0 A continuous output with a 2.0 A inrush for less than 100 ms. Q: How is the module protected against overloads?A: Integrated 4 A current limiting with thermal shutoff and automatic reset protects the module, while an external fuse is recommended for added safety. Q: Can the output be configured for different behaviors?A: Yes, outputs can be set for momentary or continuous pulse operation based on system requirements.
$200.00 $100.00
-
EMERSON EMERSON SE4303T02 Thermocouple/mV CHARM Module | DeltaV I/O
Product Description Overview The SE4303T02 by EMERSON is a high-precision thermocouple and low-level millivolt CHARM module designed for DeltaV electronic marshalling systems. It accurately measures temperature and voltage signals, supporting thermocouple types J, K, E, B, and N. The module ensures signal integrity through galvanic isolation and cold junction compensation, while built-in diagnostics monitor signal quality and detect faults. Its compact design allows seamless integration into DeltaV CHARM I/O cards, making it ideal for chemical, power generation, and oil & gas applications. Key Features High-resolution thermocouple and millivolt input for precise measurements Supports thermocouple types: J, K, E, B, N Galvanic isolation for each input sensor, tested to 1000 VDC Cold junction compensation with ±1.0°C accuracy over -40°C to 85°C 24-bit A/D converter for exceptional resolution Built-in diagnostics for open sensor detection, fault identification, and signal validation Easy pluggable installation into DeltaV CHARM I/O cards Low power consumption with 0.30 W heat dissipation Technical Specifications Specification Details Model / Part Number SE4303T02 CHARM Type Thermocouple/mV Input Voltage Input Range Typically ±100 mV Accuracy High-precision for temperature readings Resolution 24-bit A/D, sensor-dependent Repeatability 0.05% of span Calibration Factory-calibrated, no field calibration required Isolation Each sensor galvanically isolated; tested to 1000 VDC Common Mode Rejection 90 dB (DC/50/60 Hz) Power Requirement 22 mA max @ 24 VDC Cold Junction Compensation ±1.0°C accuracy, -40°C to 85°C Open Sensor Detection Yes Heat Dissipation 0.30 W Installation Pluggable into CHARM I/O cards, DeltaV compatible Diagnostics Built-in fault detection and signal validation Certifications Industrial safety and performance standards compliant Applications Optimized for industrial environments requiring precise temperature or millivolt signal monitoring. Typical deployments include chemical plants, power generation facilities, and oil & gas operations where reliability and signal accuracy are critical. FAQ Q: Which thermocouples are compatible with this module?A: The SE4303T02 supports J, K, E, B, and N type thermocouples. Q: Does this module require field calibration?A: No, the module is factory-calibrated for immediate installation and operation. Q: How is signal integrity ensured?A: Each sensor input is galvanically isolated, and cold junction compensation maintains accurate temperature readings. Q: Can it detect faults automatically?A: Yes, built-in diagnostics detect open sensors and validate signal quality.
$200.00 $100.00
-
EMERSON EMERSON SE4601T07 Display Panel Module | Industrial Operator Interface
Product Description Overview The SE4601T07 from EMERSON is a display panel module designed for industrial control systems, providing operators with real-time system monitoring and visualization. Its compact form factor allows easy integration into control panels while supporting advanced network communication for seamless operation across multiple Logix processors. Key Features Real-time operator interface for system monitoring and control Integrated diagnostic LEDs to indicate module status, I/O activity, and network health Compact panel-mount design for efficient use of space Supports both EtherNet/IP and ControlNet communications Enables tag sharing across compatible Logix controllers Technical Specifications Specification Details Model / Part Number SE4601T07 Display Type Graphic LCD with backlight Dimensions 20 mm × 20 mm Weight 1 kg Operating Voltage 24 VDC nominal Communication Protocols EtherNet/IP, ControlNet Diagnostic LEDs Communication status, module health, I/O activity Operating Temperature 0°C to 60°C Storage Temperature -20°C to 85°C Relative Humidity 5% to 95%, non-condensing Applications Ideal for manufacturing plants, process control systems, and industrial automation environments requiring compact operator interfaces with reliable diagnostics and network integration. FAQ Q: Is this display module compatible with multiple Logix processors?A: Yes, the SE4601T07 supports tag sharing across Logix controllers for synchronized monitoring. Q: Can it operate in extreme environmental conditions?A: The unit is designed for industrial environments, operating between 0°C and 60°C with 5–95% non-condensing humidity. Q: Which network protocols are supported?A: This display panel supports both EtherNet/IP and ControlNet communications for flexible integration.
$200.00 $100.00
-
EMERSON DeltaV KJ2005X1-SQ1 FM Series Hazardous Area Controller
Product Description Overview The KJ2005X1-SQ1 is a DeltaV S-Series Smart Quadrant (SQ) Controller engineered for hazardous environments. Designed for reliable operation under extreme temperatures and harsh industrial conditions, this controller meets multiple international certifications for explosive atmospheres and industrial safety. Certifications & Compliance Hazardous Atmosphere Ratings: ATEX: II 3G Ex ec IIC Gc (FM19ATEX0173U) IECEx: FMG 19.0019U UKEX: FM21UKEX0017U Class I / Division 2 Approvals: CL. I Div. 2 GP. A,B,C,D Zone 2: AEx/Ex ec IIC Gc (FM17CA0145U / FM17US0286U) Power Requirements Local Bus Power: +5 VDC, 1.4 A Environmental Specifications Operating Temperature: -40°C to +70°C Shock Resistance: 10 g, ½ sine wave, 11 ms Vibration Resistance: 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz) Airborne Contaminants: ISA-S71.04–1985, Class G3 Humidity: 5–95% relative, non-condensing Installation & Operation Guidelines Installation, removal, and operation must follow DeltaV Zone 2 hazardous area instructions. Network interfaces must remain below 60 VAC or 75 VDC to prevent hazardous conditions. Removal or insertion is only permitted in non-hazardous areas when powered. Maintenance No user-serviceable components; disassembly is not recommended. Calibration is factory-set and does not require field adjustment. Applications Ideal for chemical plants, oil & gas facilities, and industrial environments requiring precise remote monitoring and control under hazardous conditions. FAQ Q: Can this controller be powered while installed in a hazardous area?A: No, installation or removal must occur in a verified non-hazardous environment. Q: Does the controller require calibration after installation?A: No calibration is required; all units are factory-calibrated. Q: Are there comparable models for different hazardous ratings?A: DeltaV S-Series offers other SQ controllers rated for Zone 1 and Class I Division 1 environments for higher-risk areas. Technical Specifications Table Specification Details Model / Part Number KJ2005X1-SQ1 Power Supply +5 VDC, 1.4 A Operating Temperature -40°C to +70°C Shock 10 g, ½ sine, 11 ms Vibration 1 mm P–P (2–13.2 Hz); 0.7 g (13.2–150 Hz) Airborne Contaminants ISA-S71.04 Class G3 Humidity 5–95% non-condensing Certifications ATEX II 3G Ex ec IIC Gc, IECEx, UKEX, Class I Div 2 GP A,B,C,D Maintenance No user-serviceable parts, factory-calibrated
$200.00 $100.00
-
EMERSON Emerson DeltaV VE Hazardous Area I/O Module | S-Series Safety Certified
Product Description Overview The Emerson VE Hazardous Area Module is engineered for safe, high-reliability operation in Zone 2 and Class I, Division 2 environments. Designed for DeltaV™ S-Series distributed control systems, it supports both Local Bus and field power configurations and operates under extreme environmental conditions. Hazardous Area Certifications ATEX/IECEx: II 3G Ex ec IIC Gc FM: FM19ATEX0173U, FM21UKEX0017U, FM17CA0145U, FM17US0286U IECEx: FMG 19.0019U North American: Class I, Division 2, Groups A, B, C, D Zone 2: AEx/Ex ec IIC Gc Power Specifications Local Bus: 12 VDC at 15 A Field Power (8-wide carrier): 30 VDC at 3 A per card Maximum Field Power Supply: 30 VDC Environmental Ratings Operating Temperature: -40°C to +70°C Shock Resistance: 10 g, ½ sine wave, 11 ms Vibration Tolerance: 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz) Humidity: 5–95% non-condensing FAQ Q: Can the module be inserted while the system is powered?A: No, all carriers and modules must be de-energized prior to insertion or removal. Q: Is calibration required?A: No field calibration is needed; the module is factory-configured. Q: Can this module handle harsh environmental conditions?A: Yes, it supports wide temperature ranges, vibration, shock, humidity, and Class G3 airborne contaminants. Similar Modules: DeltaV S-Series Standard I/O Modules: Non-hazardous area versions with similar power requirements VE4000-Series Redundant Modules: Designed for critical applications with dual bus support
$200.00 $100.00
-
EMERSON DeltaV Emerson VE4001S2T2B6 | 32-Channel Discrete Input Module
Product Description Overview The Emerson VE4001S2T2B6 is a 32-channel discrete input (DI) module designed for DeltaV™ mM-series traditional I/O systems. Engineered for high-density signal acquisition, it supports 24 VDC dry-contact inputs and provides reliable operation in harsh industrial environments. Its plug-and-play architecture and keyed terminal design ensure fast, error-free installation. Key Features 32-channel high-density discrete input configuration Compatible with 24 VDC dry-contact signals Plug-and-play for rapid deployment Keyed terminals prevent wiring mistakes Certified for hazardous locations: FM, CSA, ATEX, IECEx, ABS, DNV, ACSE10 Technical Specifications Input Characteristics Channel Count: 32 Input Type: 24 VDC dry-contact (Plus) Input Impedance: 5 kΩ ON Detection Current: >2 mA Isolation Voltage: 1500 VDC System Compatibility: DeltaV™ mM-series I/O modules Environmental Ratings Operating Temperature: -40°C to 70°C Storage Temperature: -40°C to 85°C Humidity: 5%–95%, non-condensing Shock Resistance: 10 g, 11 ms half-sine wave Vibration Tolerance: 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) Protection Rating: IP20 Certifications & Hazardous Area Ratings FM: Class I, Division 2 ATEX/IECEx: Ex II C T4 CSA, ABS, DNV, ACSE10 compliance Applications Ideal for large-scale process control systems where multiple discrete inputs are required. Commonly deployed in chemical plants, oil and gas facilities, and power generation environments. Suitable for hazardous areas due to full FM and ATEX/IECEx compliance. FAQ Q: Can this module detect low-current inputs?A: Yes, the ON detection threshold is >2 mA, suitable for standard 24 VDC dry-contact signals. Q: Is special calibration required?A: No calibration is necessary; the module is factory configured for immediate deployment. Q: What makes this module suitable for hazardous areas?A: The module carries FM Class I, Division 2 and ATEX/IECEx Ex II C T4 ratings, ensuring safe operation in classified zones. Similar Model Comparison: VE4001S2T2B5: 16-channel discrete input for smaller systems VE4001S2T3B6: 32-channel DI with added redundancy support
$200.00 $100.00
-
EMERSON Emerson VE4003S2B9 16-Channel HART Analog Input Module
Product Description Overview The Emerson VE4003S2B9 is a high-density, 16-channel analog input module designed for DeltaV™ systems, supporting 4-20 mA signals with full HART communication capability. Engineered for reliability and precise measurement, this module enables seamless integration into distributed control systems with plug-and-play installation. Key Features Supports HART protocol for smart device communication. High-density 16-channel analog input configuration. Plug-and-play design for simplified deployment. Optical isolation per channel for enhanced signal integrity. Technical Specifications Input Characteristics Number of Channels: 16, 2-wire 4-20 mA HART Nominal Signal Range: 4-20 mA Full Signal Range: 2-22 mA (includes over-range protection) Transmitter Power: Minimum 13.5 V at 20 mA, maximum 29 mA Isolation: Optical, tested to 1000 VDC Field Circuit Power: 500 mA max at 24 VDC ±10% Local Bus Current: Simplex: 85 mA typical, 150 mA max Redundant: 110 mA typical, 200 mA max Performance Accuracy: ±0.2% of span across operating temperature Resolution: 16-bit A/D converter Repeatability: ±0.05% of span Roll-Off Frequency: -3 dB at 2.7 Hz, -20.5 dB at 20 Hz HART Scan Time: 600–800 ms per enabled channel Calibration: Factory calibrated, no field calibration required Environmental Conditions Operating Temperature: -40°C to 70°C Storage Temperature: -40°C to 85°C Humidity: 5%–95% non-condensing Protection Rating: IP20 Shock: 10 g (V2-sine wave, 11 ms) Vibration: 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) Physical Dimensions Height: 10.7 cm (4.2 in) Width: 4.1 cm (1.6 in) Depth: 10.5 cm (4.1 in) Applications Ideal for process industries requiring high-accuracy measurement from multiple 4-20 mA sensors, including chemical processing, oil and gas, and power generation. Supports advanced HART-enabled devices for real-time diagnostics and monitoring. FAQ Q: Does the module require calibration?A: No field calibration is necessary; factory calibration ensures accurate measurements. Q: Can this module operate in high-temperature environments?A: Yes, it functions reliably in temperatures from -40°C to 70°C. Q: Is HART communication supported for all channels?A: Yes, all 16 channels support HART-enabled devices. Similar Models Comparison: VE4003S2B8: Supports fewer channels or basic 4-20 mA inputs without HART. VE4003S2C1: Designed for redundant bus configurations with higher current capacity.
$200.00 $100.00
You have seen 840 out of 4916 products