The 3250-L532M is a specialized Remote Terminal Unit (RTU) built upon the reliable SLC 5/03 processor architecture. Designed for decentralized control, this module enables efficient data acquisition and local logic execution in demanding industrial environments, including electrical substations, oil and gas infrastructure, and large-scale mining operations. By maintaining high-speed serial connectivity and local processing capabilities, it ensures operational continuity at the network edge, effectively isolating field-level faults from the central control system.Features
Integrated Communication: Features native Modbus Slave protocol support on Channel 0, allowing for direct integration into existing SCADA frameworks without the need for external protocol converters.
Flexible Serial Connectivity: Equipped with three RJ45 ports: one dedicated RS-232 configuration port and two application-specific ports (PRT1 and PRT2) that support RS-232, RS-422, and RS-485 physical layers.
Robust Processing: Leverages the standard SLC 5/03 instruction set to execute complex discrete logic and mathematical functions, providing deterministic performance for critical monitoring tasks.
Simplified Deployment: Designed for seamless integration into standard SLC 500 backplanes, utilizing the existing power and communication infrastructure.
Technical Specifications
Model
3250-L532M
Processor Base
SLC 5/03
Configuration Port
1 x RJ45 RS-232
Application Ports
2 x RJ45 (RS-232/422/485)
Protocols
Modbus Slave (Ch 0), DH-485, ASCII
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Humidity
5% to 95% (Non-condensing)
Power Requirements
Integrated SLC Backplane Power
Installation Guidelines
Ensure the system power is disconnected before installing or removing the module from the SLC 500 chassis.
Use shielded communication cables for all serial connections to minimize EMI interference, especially in high-voltage environments.
Verify that the RJ45 port selection (RS-232/422/485) matches the specific field device requirements before finalizing wiring.
Maintain proper ventilation in the control cabinet to ensure the ambient temperature remains within the 0 to 60 deg C operating range.
Follow standard ESD precautions when handling the module to prevent damage to internal circuitry.
FAQCan this unit be used as a standalone controller? Yes, the 3250-L532M is designed for edge-of-network applications, allowing it to handle local logic and control tasks independently.What physical layers are supported on the application ports? The two application ports (PRT1 and PRT2) are software-configurable to support RS-232, RS-422, or RS-485 standards.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
The ProSoft MVI56-PDPS is a dedicated communication module engineered for the Rockwell Automation ControlLogix platform, providing a reliable interface for PROFIBUS DP Slave connectivity. This single-slot module serves as a bridge, allowing the ControlLogix processor to exchange data with a PROFIBUS DP Master network. By operating as a native I/O module, it maps data directly into the processor's memory, ensuring efficient, high-speed communication suitable for demanding industrial automation applications.Features
Designed for seamless integration with 1756 ControlLogix backplanes.
Functions as a PROFIBUS DP V0 Slave device.
Supports automatic baud rate detection ranging from 9.6 kbps up to 12 Mbps.
Offloads protocol processing from the main PLC CPU to enhance overall system performance.
Configured via standard text files and integrated into RSLogix 5000 or Studio 5000 using Ladder Logic.
Features 500 V optical isolation for enhanced signal integrity and protection.
ApplicationsThe MVI56-PDPS is frequently deployed in complex industrial environments requiring cross-protocol interoperability, including power generation, petrochemical processing, and large-scale manufacturing facilities. It is ideal for integrating legacy or third-party PROFIBUS equipment into a modern ControlLogix-based architecture.Technical Specifications
Brand
ProSoft Technology
Model
MVI56-PDPS
Backplane Compatibility
Rockwell Automation ControlLogix (1756)
Slot Width
1 (Single Slot)
Current Load
800 mA at 5 VDC; 3 mA at 24 VDC
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Relative Humidity
5 to 95 percent (Non-condensing)
PROFIBUS Interface
DB9 Female Connector
Baud Rate Support
9.6 kbps to 12 Mbps
Isolation
500 V optical isolation
Installation Guidelines
Ensure power to the 1756 chassis is disconnected before inserting or removing the module.
Always follow standard ESD (Electrostatic Discharge) prevention procedures when handling the module.
Seat the module firmly into the designated 1756 backplane slot and secure it using the integrated latching mechanism.
Use shielded PROFIBUS-compliant cabling for the DB9 interface to minimize EMI interference.
Ensure proper grounding of the ControlLogix chassis to maintain signal integrity and safety.
Verify that the module configuration file matches the intended PROFIBUS network mapping before commissioning.
FAQIs the MVI56-PDPS compatible with all ControlLogix processors?The module is designed for 1756 ControlLogix chassis. It is compatible with most ControlLogix processors that support standard I/O module communication. Please refer to your specific processor documentation to ensure compatibility with third-party communication modules.Does this module require special software for configuration?Configuration is handled via a text file that is downloaded to the module. Integration within the PLC environment is achieved using standard Ladder Logic in RSLogix 5000 or Studio 5000, requiring no proprietary software for basic setup.
DescriptionThe Prosoft MVI69-GSC is a high-performance, single-slot communication module engineered to integrate generic ASCII serial devices into the Rockwell Automation CompactLogix platform. By offloading serial data processing from the main controller, the module streamlines system performance and ensures reliable communication with peripheral equipment such as barcode scanners, industrial printers, and weighing instruments. It serves as a robust bridge between the 1769 backplane and external serial hardware, facilitating efficient data exchange in demanding industrial environments.Features
Dual independent serial ports supporting RS-232, RS-422, or RS-485 configurations.
Direct 1769 backplane interface for seamless integration with CompactLogix controllers.
Reduces CPU load by managing serial string processing via an internal database.
Supports a wide range of baud rates from 110 bps up to 115.2 kbps.
Configurable parity, data bits, and stop bits for versatile device compatibility.
ApplicationsThis module is frequently deployed in logistics, automotive assembly, and food and beverage processing. It is ideal for facilities requiring the integration of legacy serial instrumentation into modern, high-speed control architectures to reduce latency and maintain system uptime.Technical Specifications
Model
MVI69-GSC
Brand
Prosoft Technology
Compatibility
Rockwell Automation CompactLogix (1769 Backplane)
Backplane Current
800 mA at 5 VDC
Serial Ports
2 (RS-232/422/485 configurable)
Baud Rate Range
110 bps to 115.2 kbps
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Installation Guidelines
Ensure the CompactLogix rack is powered down before inserting or removing the MVI69-GSC module.
Verify that the module is properly seated and the backplane locking tab is engaged.
Use appropriate shielded cabling for serial connections to minimize EMI, especially in high-noise industrial environments.
Adhere to proper grounding practices for RS-422/485 signal commons to prevent ground loops.
Ensure the module is installed in a location with adequate ventilation to maintain operating temperatures within the specified 0 to 60 deg C range.
FAQDoes this module require external power?No, the MVI69-GSC draws all necessary operating power directly from the 1769 backplane.Can this module support multiple serial protocols simultaneously?The module features two independent ports that can be configured for different serial standards (RS-232, RS-422, or RS-485) and communication parameters, allowing for simultaneous connection to diverse field devices.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
The ProSoft MVI46-MNET is a high-performance communication module designed to provide seamless connectivity between Allen-Bradley SLC 500 control systems and Modbus TCP/IP networks. This module acts as a gateway, allowing the SLC processor to exchange data with a wide variety of Modbus-compliant devices such as sensors, drives, and other PLCs over Ethernet.Features
Designed for single-slot installation within an Allen-Bradley 1746 I/O chassis.
Supports high-speed Ethernet communication for Modbus TCP/IP protocols.
Large data capacity with support for up to 5000 words of data transfer.
Direct backplane communication with the SLC 500 processor.
Compatible with SLC 5/02 and newer processors that support M0/M1 file transfers.
Technical Specifications
Manufacturer
ProSoft Technology
Model Number
MVI46-MNET
Backplane Current Load
800 mA @ 5 V DC
Module Width
Single Slot
Data Capacity
5000 words
Compatible Chassis
Allen-Bradley 1746
Processor Compatibility
SLC 5/02 or newer (M0/M1 capable)
Installation Guidelines
Ensure the PLC chassis power is disconnected before installing or removing the module.
Insert the module into any available single slot within the 1746 chassis; ensure the backplane connector is fully seated.
Use shielded twisted-pair Ethernet cabling to minimize electromagnetic interference (EMI) in industrial environments.
Verify that the SLC processor is configured correctly for M0/M1 file access to enable proper data block mapping.
Always follow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.
FAQWhat processors are compatible with the MVI46-MNET?This module is compatible with Allen-Bradley SLC 500 series processors, specifically the SLC 5/02 or newer models that support M0/M1 file transfers.How much power does this module draw from the backplane?The MVI46-MNET consumes 800 mA of current from the 5 V DC backplane supply of the 1746 chassis.Can this module be used in any slot of the SLC 500 chassis?Yes, it is designed for a single-slot footprint and can be placed in any available slot within the 1746 chassis, provided the power supply can support the additional current load.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft 2150-AGA is a dedicated communication interface module engineered for integration within Allen-Bradley SLC 500 rack systems. This module serves as a reliable bridge for serial connectivity, allowing the SLC backplane to communicate effectively with external peripheral devices. It is frequently deployed in legacy industrial control environments to facilitate data exchange with HMIs, SCADA systems, or other serial-based field instrumentation. By providing a stable interface, the 2150-AGA supports continued operation and data acquisition in critical infrastructure sectors including power generation and water management.Features
Direct backplane mounting within the SLC 500 chassis for seamless system integration.
Supports RS-232 and RS-422 serial communication standards.
Integrated diagnostic LEDs providing real-time status monitoring of backplane activity and serial port data traffic.
Robust industrial construction designed for long-term reliability in high-interference environments.
Protocol support tailored for DF1 serial interface logic, ensuring compatibility with standard industrial communication requirements.
Technical Specifications
Model
2150-AGA
Brand
ProSoft Technology
Platform Compatibility
Allen-Bradley SLC 500
Product Type
Serial Interface Module
Communication Ports
RS-232 / RS-422
Protocol Support
DF1
Backplane Current Load
500 mA at 5 VDC
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Relative Humidity
5 to 95 percent (non-condensing)
Installation Guidelines
Ensure the SLC 500 rack power is disconnected before installing or removing the 2150-AGA module.
Slide the module into an available slot in the SLC 500 chassis, ensuring the backplane connector is fully seated and aligned.
Secure the module using the built-in chassis fasteners to ensure proper grounding and mechanical stability.
Use properly shielded serial cabling to minimize electromagnetic interference (EMI) in high-noise industrial environments.
Verify that the serial communication settings (baud rate, parity, stop bits) on the module match the requirements of the connected external device.
FAQWhat is the primary function of the 2150-AGA module?The 2150-AGA acts as a serial communication bridge for the SLC 500 platform, allowing the processor to exchange data with external serial devices via RS-232 or RS-422 protocols.Is this module compatible with all SLC 500 processors?The 2150-AGA is designed for the SLC 500 series backplane architecture; however, always verify your specific processor firmware and rack configuration to ensure compatibility with your system revision.How is the module powered?The module draws its operating power directly from the SLC 500 backplane, requiring 500 mA at 5 VDC.
The ProSoft 3100-MCM is a specialized communication interface module designed to integrate Modbus devices into the Allen-Bradley PLC-5 architecture. This single-slot module serves as a bridge, allowing the PLC to exchange data with various field instruments, including motor drives, power monitors, and process sensors. It is widely utilized in industrial environments to modernize legacy systems and provide a reliable link between the control logic and external serial peripherals.Features
Versatile Serial Ports: Equipped with two independent serial ports that support RS-232, RS-422, or RS-485 physical layers. Each port is independently configurable for Modbus Master or Slave operation.
Robust Protocol Support: Supports both Modbus RTU and ASCII protocols, handling a wide range of function codes (1, 2, 3, 4, 5, 6, 15, and 16) for comprehensive command control.
Data Reliability: Integrated hardware-level parity checking and CRC/LRC error detection maintain high data integrity over extended cable runs.
PLC-5 Integration: Designed for direct installation into the PLC-5 backplane, drawing power directly from the chassis to minimize external wiring requirements.
ApplicationsThis module is engineered for demanding industrial settings, such as oil and gas processing, power generation, and heavy manufacturing. It is ideal for scenarios requiring the PLC to function as a Master unit to poll field devices or as a Slave unit to report data to a higher-level SCADA or DCS system.Technical Specifications
Model
3100-MCM
Brand
ProSoft Technology
Backplane Current Draw
0.5 A at 5 VDC
Communication Ports
2 Serial Ports (RS-232/422/485)
Baud Rate Range
300 to 19,200 bps
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Relative Humidity
5% to 95% (Non-condensing)
Compatibility
Allen-Bradley PLC-5 series (11, 20, 25, 30, 40, 60)
Installation Guidelines
Ensure the PLC-5 chassis is powered down before inserting or removing the 3100-MCM module to prevent electrical damage to the backplane.
Verify that the module is fully seated in the slot and the chassis locking mechanism is engaged.
Use shielded twisted-pair cabling for RS-422/485 connections to minimize EMI interference in noisy industrial environments.
Properly terminate serial lines at the end of the communication bus to prevent signal reflections.
Maintain adequate airflow around the PLC-5 chassis to ensure the module operates within its specified temperature range of 0 to 60 deg C.
FAQCan the 3100-MCM ports be configured for different protocols?Yes, each of the two ports is independently configurable, allowing one port to act as a Modbus Master while the other functions as a Slave.Does this module require external power?No, the 3100-MCM draws its operating power directly from the PLC-5 backplane.
DescriptionThe ProSoft 5201-DFNT-EGD is a specialized communications gateway designed to facilitate seamless data exchange between EtherNet/IP-enabled devices and GE Ethernet Global Data (EGD) networks. This module acts as a protocol converter, allowing for robust interoperability in industrial automation environments where disparate network architectures must communicate reliably.Features
Protocol translation between EtherNet/IP and GE Ethernet Global Data (EGD).
Enables data sharing between Rockwell Automation platforms and GE Fanuc control systems.
Industrial-grade hardware designed for reliable operation in harsh environments.
Facilitates integration of legacy GE controllers into modern EtherNet/IP architectures.
Streamlines data mapping and communication configuration via standard industrial networking protocols.
ApplicationsThis gateway is primarily deployed in manufacturing and process control facilities where legacy GE PLC systems need to interface with newer EtherNet/IP-based controllers. It is commonly used in automotive assembly, food and beverage processing, and water treatment plants to bridge communication gaps between different OEM control hardware.Technical Specifications
Model
5201-DFNT-EGD
Manufacturer
ProSoft
Primary Function
EtherNet/IP to EGD Gateway
Communication Ports
Ethernet
Weight
0.4 kg
Installation Guidelines
Ensure the device is mounted in a clean, dry environment with adequate ventilation to prevent overheating.
Use shielded twisted-pair cabling for all Ethernet connections to minimize electromagnetic interference (EMI).
Verify that the power supply voltage matches the module requirements before applying power.
Always disconnect power before installing or removing the module from the DIN rail or backplane.
Ensure proper grounding practices are followed to protect sensitive electronic components from static discharge and electrical noise.
FAQWhat does the 5201-DFNT-EGD gateway do?It functions as a protocol bridge, allowing EtherNet/IP devices to read from and write to GE Ethernet Global Data (EGD) networks, enabling cross-platform communication.Is this module suitable for high-vibration environments?ProSoft gateways are built for industrial use; however, they should be mounted securely in an enclosure that meets vibration and shock specifications for the specific facility installation.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe MVI69E-MBTCP is a high-performance Modbus TCP/IP Enhanced Communication Module engineered specifically for the Allen-Bradley 1769 CompactLogix platform. This single-slot module allows a CompactLogix processor to interface seamlessly with up to 20 simultaneous Modbus Client connections over a 10/100 Mbps Ethernet link. By offloading the Modbus protocol stack from the primary CPU, it ensures that communication tasks do not interfere with control logic scan times, maintaining deterministic throughput in mission-critical applications.Features
Client/Server Versatility: Supports up to 20 Client connections with 16 commands per connection, while also functioning as a Modbus Server.
Advanced Data Handling: Native support for floating-point data movement, including configurable implementations for Enron and Daniel registers.
High-Capacity Database: Features a 10,000-word data database for centralized field data management.
Configurable I/O: Backplane I/O size is configurable to 60, 120, or 240 16-bit integers for optimized data transfer.
Integrated Diagnostics: Four front-panel LED indicators provide real-time status for configuration, application health, and backplane connectivity.
ApplicationsThis module is widely deployed in automated power substations, high-capacity water treatment facilities, and complex food and beverage production lines where reliable integration of Modbus TCP/IP devices into a CompactLogix architecture is required.Technical Specifications
Model
MVI69E-MBTCP
Platform
CompactLogix (1769)
Data Memory
10,000 words
Ethernet Rate
10/100 Mbps (RJ45)
Backplane Current
500 mA at 5.1 VDC
Power Supply Distance Rating
4
Operating Temperature
0 to 60 degC
Storage Temperature
-40 to 85 degC
Relative Humidity
5 to 95% (non-condensing)
Operating Shock
30 g
Installation Guidelines
Slot Placement: The module must be installed within 4 slots of the power supply due to the distance rating of 4.
Configuration: Requires ProSoft Configuration Builder (PCB) software for IP addressing and command structure setup.
Handling: Ensure the power is disconnected from the 1769 rack before inserting or removing the module to prevent electrical damage.
Environment: Ensure adequate ventilation within the control cabinet to maintain operating temperatures below 60 degC.
Grounding: Follow standard industrial grounding practices for the 1769 backplane to minimize EMI/RFI interference.
FAQDoes this module require external power?No, the MVI69E-MBTCP draws its power directly from the 1769 backplane. It consumes 500 mA at 5.1 VDC.Can this module act as both a Client and a Server?Yes, the module is designed to support both roles simultaneously, allowing it to initiate requests as a Client and respond to external requests as a Server.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft 3150-MCM is a specialized communication module designed to provide Modbus Master or Slave connectivity for industrial automation systems. This module serves as a bridge for integrating Modbus-compliant devices into control architectures, facilitating reliable data exchange between field instruments and the host controller. Although this model has been discontinued by the manufacturer, it remains a critical component for maintaining legacy automation systems.Features
Supports both Modbus Master and Modbus Slave operating modes.
Designed for seamless integration with compatible PLC backplanes.
Facilitates robust serial communication for industrial protocols.
Compact hardware footprint suitable for standard control cabinet layouts.
ApplicationsThe 3150-MCM is typically utilized in industrial environments requiring the integration of Modbus RTU or ASCII devices, such as variable frequency drives, power meters, sensors, and other third-party field equipment into a centralized control system.Technical Specifications
Product Model
3150-MCM
Manufacturer
ProSoft
Function
Modbus Master/Slave Communication Module
Series
Modbus Series 2
Weight
0.26 kg
Installation Guidelines
Ensure the host controller power is disconnected before installing or removing the module from the rack.
Verify that the module is firmly seated in the chassis to ensure proper backplane connection.
Use shielded communication cables to minimize electromagnetic interference (EMI) in high-noise industrial environments.
Follow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.
Ensure adequate ventilation in the control cabinet to maintain operating temperatures within the manufacturer's specified range.
FAQIs the 3150-MCM still in production?No, the ProSoft 3150-MCM has been discontinued by the manufacturer. It is primarily available through secondary market channels for maintenance and repair of existing installations.Can this module function as both a Master and a Slave?Yes, the 3150-MCM is designed to be configured as either a Modbus Master or a Modbus Slave, depending on the specific requirements of your communication network.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft MVI69-MNET is a high-performance Modbus TCP/IP communication module designed specifically for integration with Rockwell Automation CompactLogix programmable automation controllers. This module allows the CompactLogix processor to interface seamlessly with Modbus TCP/IP-enabled devices, acting as either a Client or a Server to facilitate data exchange across industrial Ethernet networks.Features
Designed for seamless integration into the Rockwell CompactLogix platform.
Supports up to 5,000 registers for extensive data handling.
Configurable as a Modbus TCP/IP Client or Server.
Supports up to 100 Client commands for complex network architectures.
Data transfer managed via standard ladder logic for simplified programming.
Occupies a single slot in the CompactLogix chassis.
ApplicationsThis module is widely utilized in industrial automation environments where CompactLogix controllers must communicate with third-party devices such as variable frequency drives (VFDs), power meters, remote I/O, and other controllers supporting the Modbus TCP/IP protocol. It is ideal for process control, energy management, and machine-to-machine communication.Technical Specifications
Product Model
MVI69-MNET
Product Type
Modbus TCP/IP Communication Module
Compatibility
Rockwell CompactLogix
Slot Requirement
1 Single-slot
Max Registers
5,000
Max Client Commands
100
Current Load
800 mA max @ 5 VDC
Data Transfer Method
Ladder Logic
Installation Guidelines
Ensure the CompactLogix chassis is powered down before inserting or removing the module.
Slide the module into the designated slot until the locking mechanism engages securely.
Use shielded Ethernet cabling for all network connections to minimize EMI interference.
Ensure proper grounding of the chassis backplane to maintain signal integrity.
Configure the module parameters using the appropriate ProSoft configuration software or via ladder logic integration as specified in the user manual.
FAQIs the MVI69-MNET compatible with all CompactLogix controllers?The MVI69-MNET is designed for the 1769 CompactLogix platform. Please verify your specific processor firmware and backplane compatibility in the ProSoft technical documentation before installation.Does this module require external power?No, the module draws its operating power directly from the CompactLogix backplane. Ensure your power supply is sized to accommodate the 800 mA current load.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft 3300-MBP is a specialized communication module designed for high-performance data interfacing within legacy industrial control systems. This PC board/add-on board provides critical networking capabilities for systems requiring Modbus Plus (MBP) protocol integration. Primarily utilized in heavy industrial environments such as oil and gas refining, chemical processing, and power generation, the 3300-MBP serves as a vital bridge between control processors and peripheral networking hardware. By ensuring robust data throughput and protocol stability, this module facilitates real-time monitoring of mission-critical assets.Features
Dedicated hardware interface for Modbus Plus (MBP) protocol.
Offloads communication processing from the host PLC to ensure optimal control logic execution.
Supports high-speed peer-to-peer communication and Global Data functionality.
Industrial-grade circuitry designed to resist electromagnetic interference (EMI).
Compatible with standard industrial network topologies, including daisy-chain and trunk-line configurations.
Optimized for deterministic data delivery in large-scale automated manufacturing.
ApplicationsThe 3300-MBP is typically deployed in legacy control architectures where Modbus Plus integration is required for system expansion or maintenance. Common applications include:
Oil and gas refining process control.
Chemical processing plant automation.
Power generation and distribution monitoring.
Large-scale manufacturing control networks.
Technical Specifications
Model
3300-MBP
Brand
ProSoft Technology
Component Type
Communication Add-On Board
Network Protocol
Modbus Plus (MBP)
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Relative Humidity
5 to 95 percent (Non-condensing)
Installation Guidelines
Ensure the host system is powered down before installing or removing the 3300-MBP module.
Handle the module by its edges to prevent electrostatic discharge (ESD) damage to sensitive components.
Ensure proper seating of the PC board within the host chassis or backplane slot.
Verify that all communication cabling is properly shielded and routed away from high-voltage lines or high-EMI sources to maintain signal integrity.
Confirm that the network topology follows Modbus Plus cabling standards, including proper termination at the end of the trunk line.
FAQIs the 3300-MBP compatible with all PLC systems?The 3300-MBP is designed for specific legacy industrial control systems that support this PC board form factor and the Modbus Plus protocol. Please verify your host system's hardware compatibility and slot requirements before installation.What environment is this module rated for?The module is rated for industrial environments with an operating temperature range of 0 to 60 deg C and non-condensing humidity levels up to 95 percent.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft MVI46-MCM is a high-performance communication module designed to allow Rockwell Automation SLC 500 processors to interface seamlessly with Modbus protocol-compatible devices. Acting as an input/output module between the Modbus network and the Allen-Bradley backplane, it facilitates asynchronous data exchange. The module features a 5000-word register space for efficient data transfer, supporting both Master and Slave configurations across its communication ports.Features
Dual-port interface supporting RS-232, RS-422, or RS-485 physical layers.
Configurable as a Modbus Master or Slave device.
Supports up to 100 commands per port in Master mode.
Optimized polling characteristics to manage communication with problematic slave nodes.
Direct ladder logic control for command execution.
Single-slot module design for Allen-Bradley 1746 chassis.
Applications
SCADA system integration and data concentration.
Pulp and paper mill process control and motor drive management.
Mining and heavy material handling, including conveyor and crushing equipment.
Burner and boiler management systems.
Food and beverage processing, including weigh scales and temperature controllers.
Automotive manufacturing, including robotic welding and CNC station monitoring.
Technical Specifications
Product Model
MVI46-MCM
Manufacturer
ProSoft Technology
Backplane Current Load
800 mA at 5.1 VDC
Operating Temperature
0 to 60 degC (32 to 140 degF)
Storage Temperature
-40 to 85 degC (-40 to 185 degF)
Relative Humidity
5 to 95% (non-condensing)
Vibration
5 g from 10-150 Hz
Module Width
Single slot
Compatible Rack
Allen-Bradley 1746 chassis
Installation Guidelines
Ensure the SLC 500 processor is powered down before inserting or removing the module from the chassis.
The module must be installed in a local or extended I/O rack (0-3) of the SLC 500 system; it does not support remote I/O rack installation.
Use appropriate shielded cabling for RS-422/485 connections to minimize EMI interference.
Ensure proper grounding of the chassis to maintain signal integrity.
Follow standard ESD precautions when handling the module to prevent damage to internal circuitry.
FAQsWhat is the MVI46-MCM?The ProSoft Technology MVI46-MCM is a Modbus Communication Module for Allen-Bradley SLC 500 systems, supporting Master or Slave protocols on two configurable serial ports.Can the MVI46-MCM be placed in a remote rack?No, it must reside in the local or extended I/O rack (0-3) of the SLC 500 system.What is the difference between MVI46-MCM and 3150-MCM?The MVI46-MCM is a faster, modern module supporting up to 115.2 kbps and 100 commands per port, whereas the 3150-MCM is a legacy version with lower performance specifications.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft MVI56-MCM is a high-performance Modbus Master/Slave communication module specifically designed for the Rockwell Automation ControlLogix platform. This module provides seamless integration for serial devices into the ControlLogix backplane, enabling reliable communication via RS-232, RS-485, or RS-422 interfaces. It serves as a bridge for legacy equipment and specialized industrial sensors, supporting both Modbus RTU and ASCII protocols.Features
Dual serial ports independently configurable as Modbus Master or Slave.
Supports RS-232, RS-485, and RS-422 physical interfaces.
User-controlled 5,000-word database for efficient data exchange between the processor and the network.
Includes specialized support for Enron and Daniel floating-point implementations.
Optical isolation from the backplane (rated at 500 V) for enhanced signal integrity and safety.
Real-time status indicators for module health, backplane transfer, and serial communication activity.
Applications
Oil & Gas: Remote monitoring and control for pipelines and offshore platforms.
Water and Wastewater: Integration of remote stations into SCADA systems.
Food Processing: Connecting specialized processing equipment to the main PLC network.
Pulp and Paper: Interfacing legacy machinery with modern automation controllers.
Mining: Coordinating large-scale industrial equipment on a unified network.
Technical Specifications
Product Model
MVI56-MCM
Backplane Current Load
800 mA @ 5 VDC / 3 mA @ 24 VDC
Operating Temperature
0 to 60 degC (32 to 140 degF)
Storage Temperature
-40 to 85 degC (-40 to 185 degF)
Data Format
7-8 data bits, 1-2 stop bits, parity (none, odd, even)
Isolation
500 V optical isolation
Protocol Support
Modbus RTU (binary) and ASCII
Weight
0.25 kg
Installation Guidelines
Ensure the ControlLogix chassis is powered down before inserting or removing the module to prevent electrical damage.
Seat the module firmly into the designated slot on the ControlLogix backplane and secure the top and bottom retaining screws.
Use shielded communication cables for serial connections to minimize EMI interference in industrial environments.
Ensure proper grounding of the serial cable shields at the appropriate termination points.
The module is configured using standard ladder logic within the Studio 5000 / RSLogix 5000 environment.
Maintain adequate ventilation around the chassis to ensure operation within the specified 0 to 60 degC range.
FAQsWhat is the difference between MVI56-MCM and MVI56-MCMR?The MCM version uses a larger I/O image (250 input/248 output words) and is typically preferred for local chassis use. The MCMR version uses a smaller I/O image (42 input/42 output words), making it better suited for remote racks over ControlNet to reduce bandwidth consumption.How do I handle more than 100 commands per port?While each port's standard command list supports up to 100 entries, you can utilize Event Command control blocks to trigger additional Modbus commands directly from your PLC ladder logic.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft MVI56-MCMR is a specialized Modbus Master/Slave communication module designed for the Rockwell Automation ControlLogix platform. It is specifically optimized for remote chassis applications, such as those utilizing ControlNet, where bandwidth optimization is critical. By utilizing a reduced 42-word Input/Output image, the MVI56-MCMR minimizes bandwidth impact compared to standard modules, making it an ideal choice for complex, distributed control systems.Features
Optimized for Remote Racks: Designed for ControlNet and remote chassis environments to reduce bandwidth consumption.
Dual Serial Ports: Features two configurable serial ports supporting RS-232, RS-422, and RS-485 physical standards.
Flexible Baud Rates: Supports communication speeds ranging from 110 baud up to 115,200 baud.
Configuration: Configured via ProSoft Configuration Builder (PCB) with integration into RSLogix 5000 using Add-On Instructions (AOI).
Visual Diagnostics: Integrated LED indicators provide real-time status updates for communication and module health.
Applications
Oil and Gas: Data acquisition for pipelines and offshore platform monitoring.
Water and Wastewater: Managing data exchange between control systems and remote monitoring stations.
Food Processing: Integration of automated production line equipment.
Mining, Pulp, and Paper: Connecting legacy serial equipment to modern ControlLogix architectures.
Technical Specifications
Model
MVI56-MCMR
Backplane Current (5 VDC)
800 mA
Backplane Current (24 VDC)
3 mA
Operating Temperature
0 to 60 degC
Slot Requirements
1 Slot
Communication Standards
RS-232, RS-485, RS-422
Baud Rate
110 to 115,200 bps
I/O Mapping
42-word reduced image
Installation Guidelines
Power Off: Always remove power from the ControlLogix chassis before inserting or removing the module to prevent electrical damage.
Slot Placement: The module occupies one slot in the ControlLogix rack. Ensure it is seated firmly and the locking tab is engaged.
Jumper Configuration: Physical serial standards (RS-232/422/485) are selected via jumpers located at the bottom of the module. Ensure these are set correctly before installation.
Wiring: Use a minimum phase wire size of 1.3 mm squared. Ensure proper shielding for serial cables to minimize EMI in industrial environments.
Grounding: Follow standard industrial grounding practices for the chassis to ensure signal integrity.
FAQWhat is the primary difference between MVI56-MCM and MVI56-MCMR?The MVI56-MCMR is optimized for remote chassis applications by using a reduced 42-word I/O image to save bandwidth, whereas the MVI56-MCM uses a larger 250-word image. Additionally, the MCMR does not support the Modbus Pass-Thru feature.How is the module configured?The MVI56-MCMR is configured using an offline file created in ProSoft Configuration Builder (PCB) and integrated into the processor using Add-On Instructions (AOI) within RSLogix 5000.Can I prevent data loss during a power cycle?Yes, you can use the Initialize Input Image parameter to cache values from the processor so they are not reset to zero during a module reset or power loss.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft MVI56-MNET is a high-performance network interface module designed specifically for Rockwell Automation ControlLogix processors. This module enables seamless integration between ControlLogix systems and Modbus TCP/IP-compatible devices, acting as a bridge to facilitate data exchange in industrial automation environments. It supports both Client and Server modes, providing flexibility for various network architectures.Features
Designed for seamless integration with Allen-Bradley ControlLogix backplanes.
Supports Modbus TCP/IP protocol for robust industrial communication.
Configurable as a Modbus TCP/IP Client or Server.
Includes one RJ45 Ethernet port for network communication and one RJ45 serial port for local configuration.
Facilitates data transfer between ControlLogix processors and third-party Modbus devices.
ApplicationsThe MVI56-MNET is widely utilized in industrial control systems where Allen-Bradley PLCs must communicate with external Modbus-enabled hardware, such as variable frequency drives (VFDs), power meters, remote I/O, or other third-party controllers. It is commonly found in oil and gas, water/wastewater, and manufacturing process control applications.Technical Specifications
Product Model
MVI56-MNET
Manufacturer
ProSoft
Protocol
Modbus TCP/IP
Compatibility
Allen-Bradley ControlLogix
Ethernet Port
1 x RJ45 (Modbus)
Configuration Port
1 x RJ45 (Serial)
Tariff Code
8537101190
Installation Guidelines
Ensure the ControlLogix rack is powered down before inserting or removing the MVI56-MNET module.
Slide the module into an available slot in the ControlLogix chassis and secure it using the top and bottom locking tabs.
Use shielded twisted-pair Ethernet cabling for the Modbus TCP/IP connection to minimize electromagnetic interference (EMI).
Connect the configuration cable to the serial port for initial setup and parameter configuration via ProSoft Configuration Builder.
Verify that the module status LEDs indicate successful backplane communication and network link activity after power-up.
FAQDoes the MVI56-MNET require external power?No, the module is powered directly through the ControlLogix backplane once properly seated in the chassis.Can this module act as both a Client and a Server?Yes, the MVI56-MNET is capable of operating as a Modbus TCP/IP Client, Server, or both simultaneously, depending on the configuration.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe MVI46-DFNT functions as a high-speed EtherNet/IP Client/Server communication interface specifically designed for the Allen-Bradley SLC 500 platform. This module enables SLC processors to interface seamlessly with modern Ethernet-based controllers, HMI systems, and SCADA software without requiring complex ladder logic for protocol encapsulation. In heavy industrial environments such as automotive assembly, wastewater treatment, and food processing, the MVI46-DFNT serves as a critical bridge for migrating legacy hardware to standardized network architectures. By facilitating real-time data exchange and remote diagnostics, it minimizes operational latency and provides a cost-effective path to modernizing control systems.Features
Dual-Protocol Capability: Operates simultaneously as both an EtherNet/IP Client and Server, allowing the SLC 500 to initiate commands and respond to upstream data requests.
Client Specifications: Supports up to 100 user-defined commands for data transfer with network devices using DF1 over Ethernet encapsulation or PCCC commands.
Server Functionality: Allows remote devices to read from and write to the SLC processor's data files, acting as a native Ethernet-connected node.
Backplane Integration: Utilizes a single-slot backplane interface to exchange data with the SLC 500 processor via M0 and M1 files.
Physical Interface: Equipped with a standard 10/100 Base-T RJ45 port with automatic link negotiation for stable connectivity in industrial environments.
ApplicationsThe MVI46-DFNT is ideal for system integrators and plant engineers looking to integrate legacy SLC 500 controllers into modern Ethernet/IP networks. Common applications include data acquisition for SCADA systems, HMI connectivity, and peer-to-peer communication between disparate automation controllers in manufacturing and process control facilities.Technical Specifications
Model
MVI46-DFNT
Brand
ProSoft Technology
Compatibility
Allen-Bradley SLC 5/02, 5/03, 5/04, 5/05 Chassis
Backplane Current Draw
800 mA at 5 VDC
Ethernet Port
1 x RJ45 Connector
Communication Rate
10/100 Mbps (Auto-sensing)
Operating Temperature
0 to 60 deg C
Storage Temperature
-40 to 85 deg C
Relative Humidity
5% to 95% (Non-condensing)
Installation Guidelines
Slot Placement: The module is designed for installation in any available slot of an Allen-Bradley SLC 500 chassis. Ensure the chassis is powered down before inserting or removing the module.
ESD Precautions: Always use a grounded wrist strap or similar ESD protection when handling the module to prevent damage to internal circuitry.
Wiring: Use shielded Category 5 or higher Ethernet cabling for the RJ45 port. Route communication cables away from high-voltage power lines and sources of electromagnetic interference (EMI).
Configuration: The module requires initial configuration via the serial port or Ethernet port using ProSoft Configuration Builder (PCB) software to define the communication parameters and command list.
FAQDoes the MVI46-DFNT require special ladder logic?No, the module is designed to minimize ladder logic requirements. It uses M0 and M1 file transfers for data exchange, keeping the processor overhead low.Can this module communicate with non-Allen-Bradley devices?Yes, as an EtherNet/IP Client/Server, it can communicate with any device that supports the EtherNet/IP protocol, including third-party PLCs, HMIs, and industrial sensors.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
DescriptionThe ProSoft MVI69E-MBS is an Enhanced Modbus Serial Communication Module designed specifically for integration with Rockwell Automation CompactLogix programmable automation controllers. This module enables seamless data exchange between the CompactLogix backplane and Modbus serial devices, supporting both Modbus RTU and ASCII protocols. It serves as a high-performance interface for connecting field devices such as drives, sensors, and power monitors to the control system.Features
Compatible with Rockwell Automation CompactLogix platforms.
Supports Modbus Master and Slave configurations.
Configurable via ProSoft Configuration Builder software.
Supports up to 250 commands per master port.
Selectable baud rates ranging from 110 to 115 kBaud.
Configurable stop bits (1 or 2) and parity settings.
Flexible I/O data sizing: 60, 120, or 240 16-bit integers.
ApplicationsThis module is widely used in industrial automation environments requiring serial communication integration, including:
Oil and gas pipeline monitoring and control.
Water and wastewater treatment plant instrumentation.
Power distribution and substation automation.
Manufacturing process control involving legacy serial equipment.
Technical Specifications
Parameter
Specification
Product Model
MVI69E-MBS
Platform Compatibility
CompactLogix
Current Load
500 mA at 5 VDC
Baud Rate
110 to 115 kBaud
Commands per Master Port
250
I/O Size
60/120/240 16-bit integers
Stop Bits
1 or 2
Installation Guidelines
Ensure the CompactLogix rack is powered down before inserting or removing the MVI69E-MBS module.
Slide the module into the appropriate slot on the backplane and secure it using the integrated locking mechanism.
Use shielded twisted-pair cabling for all serial connections to minimize electromagnetic interference (EMI).
Ensure proper grounding of the serial cable shield at one end to prevent ground loops.
Configure the module using the ProSoft Configuration Builder via the dedicated configuration port before full system deployment.
Verify that the module status LEDs indicate normal operation after power-up.
FAQWhat software is required to configure the MVI69E-MBS?The module is configured using the ProSoft Configuration Builder software, which provides a user-friendly interface for setting up communication parameters and mapping data.Can this module act as both a Master and a Slave?Yes, the MVI69E-MBS is designed to support both Modbus Master and Slave functionality, allowing it to act as a bridge between different serial devices and the CompactLogix controller.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
ملخص
ال MVI56-DFCM تتيح وحدة PLC من ProSoft التكامل السلس لأجهزة Modbus RTU/ASCII في Allen-Bradley كونترول لوجيكس الأنظمة. يدعم ما يصل إلى 32 جهازًا، كل منها قابل للتكوين كجهاز رئيسي أو تابع، مما يعزز التوافق عبر الشبكات الصناعية.
المواصفات الفنية
مواصفة
التفاصيل
رقم الموديل
MVI56-DFCM
مسلسل
كونترول لوجيكس
الشركة المصنعة
بروسوفت
نوع الوحدة
وحدة PLC
أبعاد
3.5 × 14 × 14.5 سم
وزن
0.45 كجم
نظام
وحدة التحكم المنطقية القابلة للبرمجة
رمز النظام المنسق
8537101190
أصل
الولايات المتحدة الأمريكية
حالة
علامة تجارية جديدة
مهلة
في الأوراق المالية
متوقف
نشيط
الحد الأدنى لكمية الطلب
1
تواصل
جهاز توجيه إيثرنت
الميزات الرئيسية
يدعم ما يصل إلى 32 جهاز Modbus RTU/ASCII.
كل جهاز قابل للتكوين كجهاز رئيسي أو تابع.
يقوم بتوصيل بيانات Modbus إلى ذاكرة ControlLogix.
يتضمن تشخيصات لمراقبة صحة الشبكة.
تصميم مضغوط يناسب هيكل ControlLogix القياسي.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
نظرة عامة على المنتج
ال بروسوفت MVI46-GSC تتيح وحدة اتصالات روكويل أوتوميشن تبادلًا سلسًا للبيانات بين وحدات التحكم المنطقية القابلة للبرمجة من ألين برادلي ووحدات التحكم GE 90-30/90-70. مصممة لـ كونترول لوجيكس منصة تدعم كل من الاتصالات التسلسلية والإيثرنت لتحقيق التكامل المرن عبر الشبكات الصناعية.
هيكلها المدمج (3.5 × 14 × 14.5 سم) ووزنها الخفيف (0.26 كجم) يُسهّلان تركيبها في لوحات التحكم. تدعم الوحدة أنواعًا متعددة من البيانات، بما في ذلك الإشارات المنفصلة والتناظرية وإشارات التحكم، مما يضمن توافقها مع مجموعة واسعة من الأجهزة.
المواصفات الفنية
مواصفة
التفاصيل
رقم الموديل
MVI46-GSC
الشركة المصنعة
بروسوفت
مجموعة المنتجات
سلسلة ControlLogix
نوع الوحدة
وحدة الاتصالات
نظام
وحدة التحكم المنطقية القابلة للبرمجة
واجهة الاتصال
جهاز التوجيه التسلسلي والإيثرنت
الأبعاد (الطول × العرض × الارتفاع)
3.5 × 14 × 14.5 سم
وزن
0.26 كجم
رمز النظام المنسق
8537101190
الحد الأدنى لكمية الطلب
1
أصل المنتج
الولايات المتحدة الأمريكية
التوفر
في الأوراق المالية
حالة
علامة تجارية جديدة
حالة متوقفة
نشيط
الميزات الرئيسية
يدعم تكامل ما يصل إلى 32 وحدة تحكم GE 90-30/90-70.
يتيح تبادل البيانات في الوقت الفعلي للتحكم في العملية ومراقبتها.
متوافق مع تنسيقات البيانات المنفصلة والتناظرية والتحكمية.
يمكن تكوينه عبر برنامج Rockwell Studio 5000 للإعداد السهل.
تساعد التشخيصات المضمنة في مراقبة صحة الشبكة وتقليل وقت التوقف.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
ملخص
ال MVI56-DFCMR تتيح وحدة الاتصالات من ProSoft تبادل البيانات بسلاسة بين شبكات Modbus RTU/ASCII وAllen-Bradley كونترول لوجيكس أنظمة PLC. تدعم ما يصل إلى 32 جهاز Modbus، كل منها قابل للتكوين كجهاز رئيسي أو تابع، مما يوفر بنية شبكة مرنة للأتمتة الصناعية.
المواصفات الفنية
مواصفة
التفاصيل
رقم الموديل
MVI56-DFCMR
مسلسل
كونترول لوجيكس
الشركة المصنعة
بروسوفت
نوع الوحدة
اتصالات إيثرنت ControlNet
أبعاد
3.5 × 14 × 14.5 سم
وزن
0.22 كجم
نظام
وحدة التحكم المنطقية القابلة للبرمجة
رمز النظام المنسق
8537101190
أصل
الولايات المتحدة الأمريكية
حالة
علامة تجارية جديدة
مهلة
في الأوراق المالية
متوقف
نشيط
الحد الأدنى لكمية الطلب
1
تواصل
جهاز توجيه إيثرنت
الميزات الرئيسية
يدعم ما يصل إلى 32 جهاز Modbus RTU/ASCII.
قابلة للتكوين كجهاز رئيسي أو تابع لإعدادات مرنة.
يقوم بتوصيل بيانات Modbus مباشرة إلى ذاكرة ControlLogix.
يتضمن تشخيصات لمراقبة الشبكة في الوقت الفعلي.
تصميم مضغوط يناسب هيكل ControlLogix القياسي.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
ملخص
ال MVI56-ADMNET تتيح وحدة الاتصال Modbus TCP/IP من ProSoft التكامل السلس للأجهزة التي تدعم Modbus في Allen-Bradley كونترول لوجيكس أنظمة PLC. تعمل كبوابة بروتوكول، مما يُسهّل تبادل البيانات بشكل موثوق بين شبكات Modbus TCP/IP وبنية ControlLogix.
المواصفات الفنية
مواصفة
التفاصيل
رقم الموديل
MVI56-ADMNET
مسلسل
كونترول لوجيكس
الشركة المصنعة
بروسوفت
نوع الوحدة
الملفات القابلة للتنزيل
أبعاد
3.5 × 14 × 14.5 سم
وزن
0.28 كجم
نظام
وحدة التحكم المنطقية القابلة للبرمجة
رمز النظام المنسق
8537101190
أصل
الولايات المتحدة الأمريكية
حالة
علامة تجارية جديدة
مهلة
في الأوراق المالية
متوقف
نشيط
الحد الأدنى لكمية الطلب
1
تواصل
جهاز توجيه إيثرنت
الميزات الرئيسية
ربط أجهزة Modbus TCP/IP مع ControlLogix PLCs.
يدعم العديد من مكونات Modbus الممكّنة في نفس الوقت.
يتضمن تشخيصات لمراقبة الشبكة في الوقت الفعلي.
قابلة للتكوين عبر برنامج Rockwell Studio 5000.
صغير الحجم وخفيف الوزن لسهولة التركيب.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
ملخص
ال MVI46-MBP تتيح وحدة الاتصالات Modbus Plus من ProSoft التكامل السلس لأجهزة Modbus RTU وASCII في Allen-Bradley كونترول لوجيكس أنظمة PLC. تدعم ما يصل إلى 32 جهازًا تابعًا، وتوفر وظائف رئيسية وتابعة، مما يضمن مرونة الاتصالات عبر الشبكات الصناعية.
المواصفات الفنية
مواصفة
التفاصيل
رقم الموديل
MVI46-MBP
مسلسل
كونترول لوجيكس
الشركة المصنعة
بروسوفت
نوع الوحدة
وحدة الاتصالات Modbus Plus
أبعاد
3.5 × 14 × 14.5 سم
وزن
0.26 كجم
نظام
وحدة التحكم المنطقية القابلة للبرمجة
رمز النظام المنسق
8537101190
أصل
الولايات المتحدة الأمريكية
حالة
علامة تجارية جديدة
مهلة
في الأوراق المالية
متوقف
نشيط
الحد الأدنى لكمية الطلب
1
تواصل
جهاز توجيه إيثرنت
الميزات الرئيسية
يدعم ما يصل إلى 32 جهاز تابع لـ Modbus RTU/ASCII.
يقدم أوضاع الاتصال الرئيسية والتابعة.
يُبسط عملية الإعداد باستخدام أدوات تكوين Studio 5000.
يتضمن تشخيصات لصحة الشبكة واستكشاف الأخطاء وإصلاحها.
صغير الحجم وخفيف الوزن لسهولة التركيب في أنظمة PLC.
نحن نقدم خدمة التوصيل في اليوم التالي من الاثنين إلى الجمعة إذا كان المنتج موجودًا في المخزون والاستثناءات في أيام العطلات.
عطلات نهاية الأسبوع
نحن لا نقدم أي تسليمات في عطلة نهاية الأسبوع.
دولي
نوفر خدمة التوصيل في اليوم التالي، حسب موقعك. تحقق من حالة طلبك عبر هذا الرابط.
وصف
ProSoft 5601-RIO-MCM هو محول اتصالات قوي مصمم لربط شبكات الإدخال/الإخراج عن بُعد (RIO) من Rockwell Automation بالأجهزة المتوافقة مع Modbus. يُمكّن هذا المحول أجهزة التحكم المنطقية القابلة للبرمجة (PLC) القديمة وأنظمة الإدخال/الإخراج الموزعة من التواصل مع معدات Modbus RTU/ASCII، مما يدعم التحديث الصناعي دون الحاجة إلى استبدال البنية التحتية الحالية.
تحديد
رقم الموديل : 5601-RIO-MCM
الوظيفة : محول اتصالات من RIO إلى Modbus RTU/ASCII
البروتوكولات المدعومة :
روكويل للإدخال والإخراج عن بعد (RIO)
Modbus RTU (رئيسي/تابع)
مودبوس أسكي
المنافذ التسلسلية :
2 منفذ RS-232/RS-485 قابل للتكوين
واجهة RIO :
متوافق مع Rockwell PLC-5 وSLC وأجهزة التحكم الأخرى المستندة إلى RIO
معدلات البود : تصل إلى 115.2 كيلوبت في الثانية
مصدر الطاقة : 12–24 فولت تيار مستمر
التركيب : مثبت على سكة DIN أو لوحة
التكوين : عبر برنامج ProSoft Configuration Builder (PCB)
التشخيص : مؤشرات LED والتشخيصات الموجودة على متن السيارة
درجة حرارة التشغيل : من 0 درجة مئوية إلى 60 درجة مئوية
بلد المنشأ : الولايات المتحدة الأمريكية