أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Yokogawa NFCP501-W15 S2 FCN-500 CPU Module

Yokogawa NFCP501-W15 S2 FCN-500 CPU Module

شكل المنتج

Yokogawa NFCP501-W15 S2 FCN-500 CPU Module Configured for real-time control execution in FCN-500 autonomous controller architectures, the Yokogawa NFCP501-W15 S2... اقرأ المزيد

رمز المنتج: NFCP501-W15 S2
بلد المنشأ: JAPAN

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Yokogawa NFCP501-W15 S2 FCN-500 CPU Module

    Configured for real-time control execution in FCN-500 autonomous controller architectures, the Yokogawa NFCP501-W15 S2 (NFCP501 CPU Module) provides direct deterministic processing and dual Ethernet communication for control and supervisory data exchange within distributed control environments managed by Yokogawa Electric Corporation.

    Suffix Breakdown & Model Matrix

    NFCP501: FCN-500 CPU module with dual Ethernet interfaces
    -W: Extended function type enabling expanded application compatibility
    1: Extended operating temperature variant
    5: Standard base type without explosion protection
    S2: Style 2 hardware revision required for E2 bus interface module compatibility

    Hardware Specifications

    Parameter Specification
    Model Brand Yokogawa NFCP501-W15 S2
    Weight approx. 0.3 kg
    Dimensions 2.2 cm x 12.4 cm x 12.6 cm
    OperatingTemp -20 degC to +70 degC
    PowerConsumption Not specified
    Processor Intel Atom E3815, 1.46 GHz
    Main Memory 256 MB ECC RAM
    SRAM 2 MB ECC, battery-backed
    Flash Memory 1 GB onboard
    External Storage SDHC slot, 4 to 32 GB
    Ethernet Interfaces 2 x 10/100/1000Base-T RJ45
    Serial Interface 1 x RS-232-C (mutually exclusive with redundancy mode)
    Task Cycle 5 ms minimum step, 20 ms recommended
    Execution Model RTOS-based dual application environment

    Process Control Communication Integrity Layer

    4-20 mA and Fieldbus Signal Deterministic Handling

    The NFCP501-W15 S2 integrates process data acquisition paths supporting analog loop integration and supervisory data mapping through standard industrial communication stacks. Within Yokogawa DCS architectures, the module is typically associated with 4-20 mA field device aggregation and higher-level protocol conversion layers, including HART multiplexing and FOUNDATION Fieldbus interface routing. Channel-level signal segregation is enforced through internal I/O architecture design, reducing cross-channel interference during high-density process scanning cycles.

    RAS and ECC Memory Execution Stability

    The CPU architecture implements ECC-protected memory regions across both main memory and SRAM domains. The error-correcting logic continuously validates memory state during runtime execution cycles. In redundant CPU configurations, state synchronization is maintained through deterministic dual Ethernet links and internal bus arbitration logic, ensuring failover alignment at task boundary transitions.

    Frequently Asked Questions

    Q: Can the NFCP501-W15 S2 operate in redundant CPU configuration?
    A: Yes. The module supports dual-redundant CPU setups with synchronized execution states over dual Ethernet interfaces and internal bus coordination logic.

    Q: Is the RS-232-C port available in redundant mode?
    A: No. The RS-232-C interface is disabled when the module is configured in duplex redundant CPU mode.

    Q: What is the role of ECC memory in this module?
    A: ECC memory corrects single-bit errors during runtime execution, maintaining data integrity in both main memory and SRAM regions.

    Field Installation Guidelines

    The module shall be installed on the designated FCN-500 base unit backplane with verified mechanical locking engagement. Ensure that Style S2 compatibility is confirmed prior to E2 bus expansion module attachment. Ethernet cabling shall be routed with separation from high-noise power conductors, maintaining shield termination at the cabinet grounding bar. For redundant configurations, ensure both CPU modules are synchronized prior to system commissioning, and avoid hot insertion of RS-232-C cabling during active duplex operation.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account