أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Terminal Board | MUD*A | Yokogawa

Terminal Board | MUD*A | Yokogawa

شكل المنتج

Yokogawa MUD*A Terminal Board The Yokogawa MUD*A, also cataloged as the MUD*A Terminal Board, operates as a dedicated hardware component... اقرأ المزيد

رمز المنتج: MUD*A
بلد المنشأ: JAPAN

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Yokogawa MUD*A Terminal Board

    The Yokogawa MUD*A, also cataloged as the MUD*A Terminal Board, operates as a dedicated hardware component for interfacing field signals with control systems within DCS process cabinets. It provides direct electrical execution between field wiring and control modules for analog, digital, and thermocouple signals.

    Hardware Specifications

    Parameter Specification
    ModelBrand Yokogawa MUD*A
    Origin Japan
    Number of Terminals 32 screw-type terminals (supports up to 64 wire points)
    Terminal Connection Screw-type clamp
    Wire Gauge Compatibility 24 AWG to 14 AWG
    Rated Voltage 250 V AC/DC
    Current Rating Up to 3 A per terminal
    Dimensions Approximately 100 mm × 75 mm × 25 mm
    Net Weight 200 g to 1.3 kg (model dependent)
    OperatingTemp –20 degC to 60 degC
    Humidity Range 10% to 95% RH, non-condensing
    Vibration Resistance 0.5 mm P-P (0–14 Hz), 2 m/s² (14–100 Hz)
    Shock Resistance 5 g for 11 ms
    Power Consumption Passive component, negligible

    Process Control Connectivity

    • Supports 4-20 mA HART loop protocol for analog signal transmission.
    • Provides channel-to-channel isolation to minimize interference between analog and digital signals.
    • Compatible with FOUNDATION Fieldbus and Profibus PA networks for integrated process control.
    • Cold junction compensation (CJC) included for thermocouple signal accuracy.

    Frequently Asked Questions

    Q: Does the MUD*A support hot-swappable modules?
    A: The terminal board itself is not designed for hot-swap operation; field wiring must be de-energized before replacement.

    Q: Can multiple signal types be connected on a single terminal?
    A: Each terminal supports one connection type. Analog, digital, and thermocouple signals must be separated according to wiring guidelines.

    Q: Are firmware updates required for the terminal board?
    A: The MUD*A is a passive hardware interface; no firmware updates are applicable.

    Field Installation Guidelines

    1. Mount the terminal board securely within the control cabinet using standard screws or DIN-rail fixtures.
    2. Maintain separation of analog and digital wiring to prevent crosstalk.
    3. Properly torque all screw terminals to ensure electrical integrity without damaging wire strands.
    4. Ground the shielded cables at one point only to reduce loop currents.
    5. Avoid routing high-current power lines adjacent to sensitive signal wires to minimize EMI.
    6. Verify signal polarity and continuity before energizing the system.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account