أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Relay Output Terminal Board | Yokogawa SARM55W

Relay Output Terminal Board | Yokogawa SARM55W

شكل المنتج

Yokogawa SARM55W Relay Output Terminal Board The Yokogawa SARM55W, also cataloged as the SARM55W relay output terminal board, operates as... اقرأ المزيد

رمز المنتج: SARM55W
بلد المنشأ: JAPAN

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Yokogawa SARM55W Relay Output Terminal Board

    The Yokogawa SARM55W, also cataloged as the SARM55W relay output terminal board, operates as a dedicated hardware component for discrete contact actuation within Yokogawa FIO digital output interface systems. Configured for field device switching in CENTUM VP / CS 3000 architectures, the Yokogawa SARM55W (SARM55W Relay Output Terminal Board) provides direct electrical relay execution between DO modules and external load circuits.

    Suffix Breakdown & Model Matrix

    • SARM: Yokogawa standard relay output terminal assembly family for FIO systems
    • 55W: 32-point wet contact relay output configuration with dual-line field power segmentation
    • No additional suffix variants or functional sub-matrix definitions are specified in the provided documentation

    Hardware Specifications

    Parameter Specification
    ModelBrand Yokogawa SARM55W
    Origin Japan
    Weight 2.2 kg
    Dimensions W 482.6 mm x H 132.5 mm (3U)
    OperatingTemp 0 to 50 degC
    PowerConsumption 24 VDC, max 0.65 A (internal circuit)
    Contact Points 32-point relay output
    Max Load 250 VAC 0.6 A per point
    Max Load 30 VDC 0.6 A per point
    Max Load 125 VDC 0.1 A per point
    Insulation Resistance >= 10 MOhm (500 VDC)
    Withstanding Voltage 2 kV field-to-case, 500 V power-to-case
    Field Device Supply Dual-line, per 16-point group

    Process Control Interface Electrical Architecture

    Yokogawa process I/O architectures implement channel-level separation and controlled electrical isolation between field switching elements and system backplane logic. The SARM55W relay terminal board supports discrete output decoupling through mechanical contact isolation, ensuring separation between 24 VDC control power domains and external load circuits.

    In DCS integration environments, channel-to-channel electrical independence is maintained through relay segmentation, minimizing cross-conduction paths under mixed AC/DC switching conditions. The terminal architecture aligns with distributed I/O designs where field wiring density is concentrated at rack-level termination points, reducing cabinet-level wiring dispersion and improving signal routing determinism in DO execution paths.

    Frequently Asked Questions

    Q: Can the SARM55W support mixed AC and DC load switching on adjacent channels?
    A: Yes. Each relay channel is electrically isolated; however, load grouping must respect per-point current limits and field wiring separation standards.

    Q: Does the board require external suppression for inductive loads?
    A: External flyback or surge suppression is required at the field device level for inductive loads to prevent contact wear and arcing.

    Q: Is hot-swap supported for the terminal board during operation?
    A: Hot-swap behavior depends on system configuration; field termination should be de-energized prior to board removal to avoid relay contact stress.

    Field Installation Guidelines

    • Maintain separation between AC and DC wiring harnesses on field terminal blocks
    • Ensure torque specification compliance for M4 terminal screws to avoid contact resistance drift
    • Use shielded cables for high-noise industrial environments and terminate shields at single-point ground only
    • Verify insulation resistance before energizing field circuits (minimum 10 MOhm recommended threshold)
    • Do not exceed per-point current limits to prevent relay contact degradation
    • Confirm correct allocation of dual-line field power groups (16-point segmentation)

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account