Schneider Electric ASMBKT185 Line Terminator Configured for signal line impedance termination in Modbus Plus communication topology within Modicon Momentum automation...
اقرأ المزيد
متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً
راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com
متاح 24/7 للاستفسارات والدعم
وصف
Schneider Electric ASMBKT185 Line Terminator
Configured for signal line impedance termination in Modbus Plus communication topology within Modicon Momentum automation platform, the Schneider Electric ASMBKT185 (AS-MBKT-185 Line Terminator) provides direct physical termination of trunk and junction box segments in Modbus Plus network structures.
Hardware Specifications
Parameter
Specification
ModelBrand
Schneider Electric ASMBKT185
Origin
France
Weight
0.03 kg
Dimensions
3.74 in x 2.76 in x 0.67 in
OperatingTemp
Not specified
PowerConsumption
Passive device, no power supply required
Core Function
Modbus Plus line termination for junction box network ends
Network Type
Modbus Plus Modbus Plus industrial communication protocol
Compatibility
990NAD23000 interface module
Protection Degree
IP20
Industrial Control Network Termination Behavior
Within Schneider Electric PLC architectures, Modbus Plus network segments rely on controlled impedance matching to prevent signal reflections across multidrop trunk lines. The ASMBKT185 implements fixed passive termination at junction box endpoints, ensuring deterministic backplane-adjacent communication stability across distributed nodes.
In systems such as Modicon Momentum automation platform, Modicon Premium automation platform, and Modicon Quantum automation platform, the termination element operates as a non-powered impedance matching node integrated into the Modbus Plus segment topology. The device does not participate in backplane bus arbitration but enforces electrical boundary conditions at segment extremities.
From a deterministic network standpoint, Modbus Plus frames require consistent reflection suppression to maintain token-passing integrity. The ASMBKT185 provides fixed termination resistance characteristics intended to stabilize differential signal amplitude across junction box transitions.
Frequently Asked Questions (FAQ)
Q: Does ASMBKT185 require external power supply? A: No. The unit is a passive termination element with no electrical consumption or active circuitry.
Q: Can ASMBKT185 be hot-swapped during Modbus Plus operation? A: Physical removal during active communication is not recommended, as termination loss may introduce signal reflection and token instability on the segment.
Q: Is polarity or orientation critical for installation? A: The device functions as a resistive termination block; however, correct junction box terminal alignment is required to maintain proper network impedance matching.
Field Installation Guidelines
ASMBKT185 shall be installed at the physical end of Modbus Plus trunk segments or designated junction box termination points. Shield continuity must be maintained across all network segments, ensuring consistent reference grounding between nodes.
Termination should only be applied at segment endpoints; dual termination within a single segment may degrade signal integrity. Cable routing must minimize loop formation and maintain standard twisted-pair shielding practices consistent with industrial fieldbus installation rules.
Mechanical mounting inside IP20 junction enclosures must ensure stable contact seating to avoid intermittent termination resistance variations under vibration.