Honeywell TC-ODJ161 24 VDC Digital Output Module
The Honeywell TC-ODJ161, also cataloged as the TC-ODJ161 24 VDC Digital Output Module, operates as a dedicated hardware component for discrete signal execution within Honeywell Experion I/O architectures. The module provides 16 isolated output channels for controlling external DC field loads through industrial control commands.
Hardware Specifications
Parameter
Specification
Model
TC-ODJ161
Brand
Honeywell
Product Type
24 VDC Digital Output Module
Module Function
Isolated Discrete Output Interface
Origin
USA
Weight
Approx. 0.33 kg
Dimensions
Not specified
Operating Temp
30 deg C full load reference; 60 deg C reduced load condition
Power Consumption
4.7 W max
Number of Output Points
16 individually isolated channels
Output Voltage Range
10 to 30 VDC
Nominal Output Voltage
24 VDC
Output Current per Point
2.0 A max at 30 deg C; 1.0 A max at 60 deg C
Maximum Module Output Current
8.0 A max at 30 deg C; 4.0 A max at 60 deg C
Surge Current Capability
4 A for 10 ms, repeatable every 2 seconds
Minimum On-State Current
1.0 mA per output
Maximum On-State Voltage Drop
1.2 VDC at 2.0 A
Maximum Off-State Leakage Current
0.5 mA per point
Output Signal Delay
Off to On: 1.0 ms max; On to Off: 2.0 ms max
Isolation Voltage
1500 VAC RMS output to backplane
Terminal Block Type
TC-TBCH 36-position terminal block
Installation Type
Honeywell control rack and I/O subsystem mounting
Channel Isolation and Process Control Interface
The TC-ODJ161 uses channel-to-channel isolation to separate field output circuits from the control backplane. This electrical design limits interference transfer between connected loads and supports direct switching of 24 VDC devices.
Moreover, Honeywell I/O modules within Experion architectures commonly integrate with process control signal paths including 4-20 mA HART loop protocol, FOUNDATION Fieldbus, and Profibus PA interfaces through dedicated I/O modules. The TC-ODJ161 performs discrete output execution rather than analog measurement or fieldbus signal processing.
Frequently Asked Questions
Q: How many discrete output channels are available on the TC-ODJ161? A: The module provides 16 individually isolated 24 VDC discrete output channels.
Q: What is the maximum output current capability of each channel? A: Each output channel supports up to 2.0 A at 30 deg C and 1.0 A at 60 deg C operating conditions.
Q: What isolation rating is provided between the output circuits and backplane? A: The module provides 1500 VAC RMS isolation between the output side and the control backplane.
Field Installation Guidelines
Install the TC-ODJ161 in the designated Honeywell I/O rack position according to system configuration requirements.
Use the specified TC-TBCH terminal block for field wiring connections.
Verify external load current requirements before connecting field devices.
Maintain correct DC polarity during field cable termination.
Separate high-current switching wiring from low-level signal cables to reduce electrical interference.
Confirm module status indicators and controller configuration after installation.