Honeywell TC-CCR014 Redundant ControlNet Interface Module Configured for redundant ControlNet communication in Honeywell Experion PKS systems, the Honeywell TC-CCR014 (TC-CCR014...
اقرأ المزيد
Configured for redundant ControlNet communication in Honeywell Experion PKS systems, the Honeywell TC-CCR014 (TC-CCR014 Redundant ControlNet Interface Module) provides direct physical network interface execution for dual-port industrial communication paths.
Hardware Specifications
Parameter
Specification
Model
TC-CCR014
Brand
Honeywell
Product Type
Redundant ControlNet Interface Module
System Platform
Honeywell Experion PKS
Communication Network
ControlNet
Network Interface
Dual-port redundant media interface
Data Transfer Rate
5 Mbps
Redundancy Function
Automatic media failover between redundant communication paths
Origin
Not specified
Weight
0.28 kg
Dimensions
3.5 x 14 x 17.2 cm (estimated shipping size)
Operating Temp
Not specified
Power Consumption
Not specified
Input Voltage
24 VDC
Mounting Type
Industrial control chassis module
Channel-to-Channel Isolation and Process Network Interface
The TC-CCR014 provides redundant ControlNet communication connectivity between control processors and distributed I/O components. The module operates as a network interface assembly supporting dual communication paths for applications requiring continuous data exchange between Experion PKS control components.
The hardware design supports isolated communication channels to minimize electrical interference between network segments. Proper cable shielding, grounding, and separation from high-voltage conductors are required to maintain signal integrity in industrial installations.
Frequently Asked Questions
Q: What communication protocol is supported by the TC-CCR014? A: The TC-CCR014 is designed for ControlNet communication networks with a nominal data transfer rate of 5 Mbps.
Q: Does the TC-CCR014 support redundant network operation? A: Yes. The module provides dual-port redundant network interface capability for redundant ControlNet media configurations.
Q: Can the module be installed without considering grounding and cable routing requirements? A: No. Installation requires proper chassis mounting, shield termination, and separation of communication wiring from sources of electrical noise.
Field Installation Guidelines
Install the TC-CCR014 in the designated Honeywell control chassis position according to the system hardware configuration.
Verify that the chassis backplane connection is fully seated before applying system power.
Route ControlNet communication cables separately from high-current power wiring and electromagnetic noise sources.
Terminate cable shields according to the site grounding standard to reduce communication interference.
Confirm redundant network connections are correctly assigned to the intended communication ports before commissioning.
Follow Honeywell Experion PKS hardware documentation for configuration, diagnostics, and module replacement procedures.
تحديد
rtl">
المزايا
موثوقية عالية في البيئات الصناعية
يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية