Honeywell TC-BATT01 Lithium PLC Backup Battery The Honeywell TC-BATT01, also cataloged as the TC-BATT01 Lithium PLC Backup Battery, provides memory...
اقرأ المزيد
متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً
راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com
متاح 24/7 للاستفسارات والدعم
وصف
Honeywell TC-BATT01 Lithium PLC Backup Battery
The Honeywell TC-BATT01, also cataloged as the TC-BATT01 Lithium PLC Backup Battery, provides memory retention power for Honeywell controller assemblies during primary power interruption conditions. The module supplies a 3.0 VDC lithium backup source for preserving stored controller data.
Hardware Specifications
Parameter
Specification
Model
TC-BATT01
Brand
Honeywell
Product Type
Lithium PLC Backup Battery
Origin
USA
Battery Chemistry
Non-rechargeable Lithium
Nominal Voltage
3.0 VDC
Rated Capacity
1700 mAh
Connector Type
Polarized application-specific connector
Weight
Approximately 0.068 kg
Dimensions
34 mm (H) x 17 mm (W) x 17 mm (D)
Operating Temp
Not specified
Power Consumption
Standby backup application, battery powered
Storage Life
Up to 10 years at 20 deg C ambient conditions
Installation Method
Controller chassis or processor module mounting
Honeywell Process Control Memory Backup Characteristics
The TC-BATT01 is designed for controller memory retention functions within Honeywell industrial control platforms. The lithium cell provides a stable backup voltage source for maintaining stored application programs, configuration parameters, and processor memory data when the primary controller power supply is unavailable.
For Honeywell controller environments, backup battery operation is separated from normal control power circuits. The module does not provide field I/O power or process signal excitation. Instead, it supports internal memory preservation circuits associated with processor hardware.
Moreover, Honeywell controller architectures may include analog and digital I/O interfaces using technologies such as 4-20 mA HART loop protocol, FOUNDATION Fieldbus, or Profibus PA connectivity. The TC-BATT01 functions independently from these communication interfaces and only maintains controller memory backup requirements.
Frequently Asked Questions
Q: Is the Honeywell TC-BATT01 a rechargeable battery module? A: No. The TC-BATT01 uses a non-rechargeable lithium cell design and requires replacement after battery service life expiration.
Q: What electrical function does the TC-BATT01 provide inside a controller assembly? A: The module provides a 3.0 VDC backup supply for maintaining processor memory contents during loss of the primary power source.
Q: Does the TC-BATT01 supply power to external I/O devices? A: No. The battery module is intended for internal memory retention circuits and does not provide operating power for external field devices or I/O modules.
Field Installation Guidelines
Verify controller compatibility and battery model identification before installation.
Disconnect the controller power source according to the applicable maintenance procedure before replacing the battery.
Confirm correct polarity alignment between the battery connector and controller interface.
Route the battery connection away from high-current power wiring and strong electromagnetic interference sources.
Inspect connector contacts for contamination or mechanical damage before installation.
Follow local regulations for disposal of lithium battery components after replacement.