أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Honeywell CC-TFB402 Field Termination Assembly Module

Honeywell CC-TFB402 Field Termination Assembly Module

شكل المنتج

Honeywell CC-TFB402 Field Termination Assembly Module Configured for field signal termination and electrical interface functions in Honeywell Experion PKS C300... اقرأ المزيد

رمز المنتج: CC-TFB402
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Honeywell CC-TFB402 Field Termination Assembly Module

    Configured for field signal termination and electrical interface functions in Honeywell Experion PKS C300 control systems, the Honeywell CC-TFB402 (CC-TFB402 Field Termination Assembly Module) provides direct physical signal connection between field wiring and control I/O hardware.

    Hardware Specifications

    Parameter Specification
    Model CC-TFB402
    Brand Honeywell
    Product Type Field Termination Assembly (FTA) / Control Circuit Board
    System Compatibility Honeywell Experion PKS C300 control system
    Module Function Field signal termination and I/O interface
    Application Category PLCs / Machine Control / PC Board PLC Add-On Board
    I/O Interface Field wiring termination interface for compatible FIM I/O modules
    Channel Configuration Dependent on associated Field Interface Module configuration
    Communication Interface I/O connection interface with compatible Honeywell control hardware
    Mounting Method Honeywell control cabinet termination assembly mounting
    Wiring Connection Field terminal connections with dedicated module interface connectors
    Brand New Status Discontinued by manufacturer
    Origin USA
    Weight 0.40 lbs

    4-20 mA HART and Field Signal Interface Characteristics

    The CC-TFB402 is designed as a termination-level hardware component within the Honeywell Experion PKS I/O architecture. The assembly provides the physical termination point for field conductors and routes electrical signals to the associated I/O processing hardware.

    For process instrumentation applications, compatible Honeywell I/O configurations may support analog communication schemes such as 4-20 mA HART loop protocol or digital field interfaces depending on the connected I/O module. Channel-to-channel isolation characteristics are determined by the paired I/O hardware and system architecture.

    The termination assembly maintains signal integrity through controlled wiring paths, proper shielding practices, and defined field cable routing. It does not perform independent signal processing or control algorithm execution.

    Frequently Asked Questions (FAQ)

    Q: Does the CC-TFB402 operate as an independent controller module?
    A: No. The CC-TFB402 is a Field Termination Assembly and provides field wiring termination and interface functions. Control execution is performed by the associated Honeywell controller and I/O modules.

    Q: Can the CC-TFB402 be installed without a compatible Honeywell I/O module?
    A: No. The assembly requires connection with the designated Honeywell field interface and control hardware configuration.

    Q: Does the CC-TFB402 support direct firmware upgrades?
    A: No. The CC-TFB402 is a passive termination/interface hardware assembly and does not contain user-upgradable firmware.

    Field Installation Guidelines

    • Install the CC-TFB402 inside the designated Honeywell control cabinet or termination area according to the system hardware layout.
    • Verify terminal assignments before connecting field conductors to prevent incorrect signal routing.
    • Use shielded instrumentation cable where required by the connected field device specification.
    • Terminate cable shields according to the plant grounding standard to reduce electrical noise interference.
    • Separate low-level analog signal wiring from high-voltage power conductors and high-current switching circuits.
    • Confirm connector engagement and mechanical fixing before system power application.
    • Perform continuity checks on field wiring before placing connected I/O channels into service.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account