Honeywell 51304437-100 MU-TAIL02 FTA Cable Assembly The Honeywell 51304437-100, also cataloged as the MU-TAIL02 FTA Cable Assembly, operates as a...
اقرأ المزيد
رمز المنتج: 51304437-100 MU-TAIL02
بلد المنشأ: USA
The Honeywell 51304437-100, also cataloged as the MU-TAIL02 FTA Cable Assembly, operates as a dedicated hardware component for signal connection between I/O processor modules and Field Termination Assemblies within Honeywell TDC 3000 and HPM systems.
Hardware Specifications
Parameter
Specification
Model
MU-TAIL02
Brand
Honeywell
Origin
USA
Product Type
FTA Cable Assembly / Tail Cable
System Compatibility
Honeywell TDC 3000 and High Performance Process Manager (HPM) architectures
Signal Interface
I/O processor module to Field Termination Assembly connection
Cable Construction
Shielded multicore cable assembly
Conductor Material
Copper conductors with EMI shielding layer
Shielding Method
Foil/braid shield for signal noise reduction
Connector Type
Factory-installed industrial connectors
Operating Temp
0 deg C to 60 deg C
Storage Temp
-40 deg C to 85 deg C
Relative Humidity
10% to 90% RH non-condensing
Power Consumption
Passive cable assembly; no independent power consumption
DCS Signal Interface and Channel Protection
Honeywell MU-TAIL02 cable assemblies support the physical signal path between control system I/O modules and termination points. The cable maintains signal continuity through shielded conductors and controlled routing inside the TDC 3000 and HPM hardware environment.
Furthermore, Honeywell process control architectures typically apply field signal conditioning methods such as 4-20 mA HART loop protocol interfaces, FOUNDATION Fieldbus / Profibus PA connectivity, and channel-to-channel isolation at the I/O module level. The MU-TAIL02 provides the passive interconnection path required for these signal processing assemblies.
The shield structure reduces electromagnetic interference coupling from adjacent industrial wiring. Therefore, correct grounding and cable separation practices directly affect analog and digital signal integrity.
Frequently Asked Questions
Q: Is the Honeywell 51304437-100 an active electronic module? A: No. The MU-TAIL02 is a passive FTA cable assembly. It does not contain signal processing circuits, firmware, or independent power input.
Q: Can the MU-TAIL02 cable be installed without considering shielding requirements? A: No. The shield termination and cable routing must follow the control system installation guidelines to reduce electrical noise and unwanted signal coupling.
Q: Does the MU-TAIL02 support direct connection between field devices and controllers? A: No. The cable provides an interconnection path between compatible Honeywell I/O hardware and Field Termination Assemblies. Field device compatibility depends on the installed I/O module configuration.
Field Installation Guidelines
Verify that the cable part number matches the installed Honeywell TDC 3000 or HPM hardware configuration before installation.
Install the cable according to the designated I/O module and FTA terminal assignment.
Maintain separation between signal cables and high-voltage power cables to reduce electromagnetic interference.
Connect cable shielding according to Honeywell grounding practices for the specific cabinet design.
Avoid excessive bending, mechanical stress, or connector strain during cabinet installation.
Confirm connector seating and locking mechanisms before system commissioning.
Inspect cable insulation and shielding condition during maintenance activities.
تحديد
rtl">
المزايا
موثوقية عالية في البيئات الصناعية
يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية