أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

GE Multilin 745-W2-P5-G5-HI Transformer Protection Relay

GE Multilin 745-W2-P5-G5-HI Transformer Protection Relay

شكل المنتج

GE Multilin 745-W2-P5-G5-HI Transformer Protection Relay The GE Multilin 745-W2-P5-G5-HI, also cataloged as the 745 Transformer Protection Relay, operates as a dedicated hardware... اقرأ المزيد

رمز المنتج: 745-W2-P5-G5-HI
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    GE Multilin 745-W2-P5-G5-HI Transformer Protection Relay

    The GE Multilin 745-W2-P5-G5-HI, also cataloged as the 745 Transformer Protection Relay, operates as a dedicated hardware component for two-winding transformer differential protection, monitoring, and control within transformer protection system platforms.

    Hardware Specifications

    Parameter Specification
    Model 745-W2-P5-G5-HI
    Brand GE Multilin
    Weight 4.8 kg
    Dimensions 9 in H x 7 1/8 in D x 7 in W
    Operating Temp -40 deg C to +60 deg C
    Power Consumption 15 W typical, 35 W maximum
    Series 745 Transformer Protection System
    Product Type Transformer Protection Relay
    Control Power Supply 90-300 VDC / 70-265 VAC
    Frequency 50 Hz / 60 Hz, tracking range 45 to 65 Hz
    Phase Current Input 5 A secondary CT input
    Ground Current Input 5 A secondary CT input
    Voltage Relay Input 60 to 120 V
    Current Burden < 0.2 VA at 5 A
    Thermal Continuous Rating 20 A continuous
    Overcurrent Withstand 500 A for 1 second
    Display 40 character LCD
    Communication Ports RS232, RS485, RS422
    Communication Protocol Modbus RTU / ASCII

    Deterministic Network and Industrial Control Interface Characteristics

    The GE Multilin 745 relay incorporates industrial communication functions for transformer monitoring and protection system integration. RS232 front panel communication provides local maintenance access, while rear RS485 and RS422 ports support Modbus RTU communication with supervisory control systems.

    The relay processes transformer electrical measurements including phase current, ground current, frequency, harmonic content, loading condition, and thermal operating parameters. Event recording functions include oscillography, waveform capture, fault records, and operational logs for protection analysis.

    The protection firmware executes transformer-specific algorithms including restrained differential protection (87T) with harmonic restraint/blocking, instantaneous differential overcurrent protection (87H), phase and ground overcurrent protection, negative sequence protection, thermal overload modeling, and volts-per-hertz overexcitation monitoring.

    Frequently Asked Questions

    Q: What current transformer inputs are supported by the 745-W2-P5-G5-HI configuration?
    A: The P5 option provides 5 A phase current CT inputs and the G5 option provides 5 A ground current CT inputs for transformer protection measurement circuits.

    Q: Does the relay support hot-swapping during energized operation?
    A: The 745-W2-P5-G5-HI is designed as a panel-mounted protection relay. Hot-swap operation is not specified. Installation and replacement should be performed with the protection circuit isolated according to site procedures.

    Q: What communication interfaces are available for integration?
    A: The relay provides an RS232 front maintenance port and RS485/RS422 rear communication ports supporting Modbus RTU protocol.

    Field Installation Guidelines

    Install the relay in a suitable protective panel enclosure with controlled wiring separation between power circuits, CT measurement circuits, communication cables, and auxiliary control wiring.

    Current transformer secondary wiring should use dedicated terminal connections with correct polarity verification before energization. CT circuits must not be opened while energized.

    Communication wiring should maintain appropriate shielding and grounding practices. Shield termination should follow the plant grounding standard to reduce electrical noise coupling.

    Provide adequate clearance for relay ventilation and service access. Verify control power polarity and voltage range before applying auxiliary supply.

    Protection settings, CT ratios, transformer parameters, and trip output logic should be validated during commissioning using approved protection testing equipment.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account