GE Multilin 369-HI-0-0-0-0-H-E 369 Motor Management Relay
Configured for three-phase motor protection and control execution in GE Multilin 369 Motor Management Relay platforms, the GE Multilin 369-HI-0-0-0-0-H-E (369 Motor Management Relay) provides direct physical and electrical execution for current monitoring, thermal modeling, trip logic, and motor operating protection functions.
Hardware Specifications
Parameter
Specification
Model
369-HI-0-0-0-0-H-E
Brand
GE Multilin / GE Vernova / GE Grid Solutions
Dimensions
29.6 cm H x 10.7 cm W x 20.5 cm L
Operating Temp
-40 deg C to +60 deg C
Power Consumption
Nominal 10-15 W, 25 VA maximum
Product Type
Motor Management Relay
Control Power Input
90-300 VDC / 70-265 VAC, 50/60 Hz
Current Inputs
1 A or 5 A secondary CT inputs
Ground Current Inputs
1 A or 5 A ground CT inputs
Digital Inputs
Optically isolated assignable inputs
Output Relays
Form-C (SPDT) trip, auxiliary, and alarm relays
Communications
Rear RS485 Modbus RTU, front RS232 setup port
Analog Outputs
Assignable 0-20 mA or 4-20 mA DC outputs
Mounting Type
Drawout panel mounting design
Environmental Protection
Conformal-coated PCB option for harsh environments
GE Multilin 369 Motor Protection and PLC/DCS Integration Features
The GE Multilin 369 relay incorporates industrial control characteristics associated with GE Multilin motor management systems, including I/O density scaling for configurable protection channels and firmware flash compatibility for device maintenance operations. The relay processes phase current inputs, ground current signals, digital status inputs, and analog outputs for integration with motor control circuits.
The unit supports protection functions including ANSI 49 thermal overload, ANSI 50/51 phase overcurrent, ANSI 50G/51G ground fault protection, ANSI 46 current unbalance protection, ANSI 37 undercurrent protection, ANSI 86 lockout operation, ANSI 48/66 start supervision, and ANSI 51R mechanical jam/stall detection.
Frequently Asked Questions
Q: What current transformer inputs are supported by the GE Multilin 369 relay? A: The relay accepts 1 A or 5 A secondary CT inputs for phase current measurement and configurable ground current inputs.
Q: What communication interfaces are available on the 369-HI-0-0-0-0-H-E model? A: The relay provides a rear RS485 port supporting Modbus RTU communication and a front RS232 port for local configuration.
Q: Does the relay support thermal monitoring during motor operation? A: Yes. The relay executes a motor thermal model that tracks thermal capacity usage, trip conditions, and estimated restart availability.
Field Installation Guidelines
Install the relay in a suitable panel cut-out location using the specified drawout mounting arrangement. Verify control power polarity and voltage range before energizing the unit.
Route CT wiring separately from high-voltage switching conductors to reduce induced electrical noise. Use shielded communication wiring for RS485 networks where required, with cable shields terminated according to site grounding practices.
Confirm CT secondary connections, digital input polarity, and output relay wiring before commissioning. For installations using the E conformal coating option, maintain enclosure protection to prevent exposure to excessive contaminants or conductive moisture.