شكل المنتج

GE L30 Line Current Differential System The GE Multilin L30, also cataloged as the L30 Line Current Differential Relay, operates as a dedicated... اقرأ المزيد

رمز المنتج: L30
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    GE L30 Line Current Differential System

    The GE Multilin L30, also cataloged as the L30 Line Current Differential Relay, operates as a dedicated hardware component for phase-segregated current differential protection and high-speed fault clearance within GE UR (Universal Relay) protection platforms.

    Hardware Specifications

    Parameter Specification
    Model L30
    Brand GE Multilin
    Origin GE UR (Universal Relay) Series
    Operating Temp -40 deg C to +60 deg C
    Protection Function Line current differential protection (87L)
    Protection Elements Distance protection (21/21N), overcurrent protection, voltage protection
    CT Input Configurable 1 A / 5 A CT secondary
    VT Input 100-240 V AC VT secondary
    Communication Interfaces Fiber optic, G.703, C37.94, Ethernet
    Network Protocols IEC 61850 Ed. 1/2, DNP 3.0, Modbus RTU/TCP/IP, IEC 60870-5-104
    Ethernet Support 100Base-FX, 100Base-TX, PRP/HSR
    Power Supply Options 110-250 V DC / 110-240 V AC or 24-48 V DC
    Enclosure Rating IP40 front panel, IP20 rear chassis

    Profinet / EtherNet-IP Deterministic Network and Firmware Compatibility

    The GE Multilin L30 integrates high-speed relay processing with modular communication and control resources within the UR hardware architecture. The device supports deterministic Ethernet-based protection communication through IEC 61850 MMS and GOOSE messaging, with redundant Ethernet options for network topology requirements.

    The relay firmware structure supports configuration management through standardized settings files and maintains compatibility with UR family engineering tools. Internal processing handles line differential calculations, synchrophasor measurement, disturbance recording, and protection logic execution within the relay processor environment.

    Frequently Asked Questions

    Q: Does the L30 support multi-terminal line differential protection configurations?
    A: Yes. The L30 supports phase-segregated line differential protection for up to three terminals with communication channel supervision and direct transfer tripping functions.

    Q: What CT and VT signal interfaces are supported by the hardware?
    A: The relay supports configurable CT modules with 1 A or 5 A secondary inputs and VT inputs rated for 100-240 V AC secondary signals.

    Q: What communication protocols are available for integration with protection networks?
    A: The L30 supports IEC 61850 Edition 1 and Edition 2, GOOSE, MMS, DNP 3.0, Modbus RTU/TCP/IP, IEC 60870-5-104, and IEEE 1588 PTP synchronization.

    Field Installation Guidelines

    Install the L30 relay in a compatible UR rack environment with correct mechanical mounting and rear terminal connection alignment. CT and VT wiring should follow protection engineering practices, including separate routing from high-voltage conductors and appropriate shielding for low-level measurement circuits.

    Fiber optic communication connections should maintain correct optical interface matching between relay terminals. Ethernet and serial communication wiring should be installed according to network grounding and shielding requirements.

    Verify control power polarity and voltage range before energizing the relay. Digital input wiring should maintain electrical isolation requirements, and output contact circuits should be connected according to the assigned protection scheme.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية