أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

GE IS200VTCCH1CBB Thermocouple Input Board

GE IS200VTCCH1CBB Thermocouple Input Board

شكل المنتج

The GE IS200VTCCH1CBB, also cataloged as the IS200VTCC Thermocouple Input Board, operates as a dedicated hardware component for thermocouple temperature signal acquisition within... اقرأ المزيد

رمز المنتج: IS200VTCCH1CBB
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف


    The GE IS200VTCCH1CBB, also cataloged as the IS200VTCC Thermocouple Input Board, operates as a dedicated hardware component for thermocouple temperature signal acquisition within the GE Mark VI Speedtronic turbine control system. The board receives E, J, K, S, and T thermocouple inputs, performs signal linearization and cold-junction compensation, and transfers processed temperature data through the VME rack interface.

    Hardware Specifications

    Parameter Specification
    Model IS200VTCCH1CBB
    Brand GE
    Origin United States
    Weight 0.45 kg
    Dimensions 2.1 x 18.8 x 26.2 cm
    Operating Temp -40 deg C to +85 deg C
    Power Consumption 24 VDC chassis supply input
    Product Type Thermocouple Input Board
    System Platform GE Mark VI Speedtronic Turbine Control System
    Thermocouple Inputs 24 channels, grounded or ungrounded
    Supported Thermocouple Types E, J, K, S, T
    Input Range -8 mV to +45 mV
    A/D Resolution 16-bit conversion
    Cold-Junction Compensation Dual references per board; six references in TMR configuration
    Accuracy +/-0.1% of full scale
    Signal Filtering High-frequency noise suppression filtering
    Cable Distance Up to 300 m
    Mounting Interface VME rack integration, compatible terminal boards
    Protection Features Conformal coating and overvoltage/current protection

    Firmware Flash Compatibility and VME Signal Processing

    The GE IS200VTCCH1CBB performs thermocouple signal conditioning through onboard analog conversion and digital processing functions. The module supports GE Mark VI controller communication through the VME backplane interface, enabling temperature data transfer between field input terminals and control processors. The board architecture supports simplex operation with TBTCH1C terminal boards and redundant configurations using TBTCH1B terminal boards for TMR signal acquisition.

    The input processing circuit provides automatic signal validation, hardware limit checking, and filtered temperature measurement. The thermocouple channels support long-distance field wiring while maintaining compensated measurement values through integrated cold-junction reference circuits.

    Frequently Asked Questions

    Q: How many thermocouple channels are supported by the IS200VTCCH1CBB?
    A: The board supports 24 thermocouple input channels with E, J, K, S, and T type thermocouple compatibility.

    Q: What is the function of the cold-junction compensation circuit?
    A: The cold-junction compensation circuit corrects the reference junction temperature effect to maintain thermocouple measurement accuracy. The board provides dual references in standard operation and additional references when configured in TMR mode.

    Q: Can the IS200VTCCH1CBB operate in redundant turbine control configurations?
    A: The board supports redundant operation when paired with compatible TMR terminal boards such as TBTCH1B within the GE Mark VI control architecture.

    Field Installation Guidelines

    Install the IS200VTCCH1CBB in the designated GE Mark VI VME rack position according to the system hardware configuration. Verify terminal board compatibility before connecting thermocouple field wiring.

    Use shielded thermocouple cables where required by site electrical practices. Connect cable shields according to the grounding scheme defined for the turbine control cabinet to reduce electromagnetic interference. Separate thermocouple wiring from high-current power conductors and switching circuits to minimize induced noise.

    Confirm thermocouple polarity, channel assignment, and terminal connections before system commissioning. Check that field cable routing, grounding, and terminal board installation meet the applicable GE Mark VI hardware documentation requirements.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية