CI856 3BSE026055R1 ABB S100 I/O Communication Interface

CI856 3BSE026055R1 ABB S100 I/O Communication Interface

شكل المنتج

ABB CI856K01 S100 I/O Communication Interface Configured for S100 I/O communication in AC 800M systems, the ABB CI856K01 (CI856 S100... اقرأ المزيد

رمز المنتج: CI856 3BSE026055R1
بلد المنشأ: Sweden

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    ABB CI856K01 S100 I/O Communication Interface

    Configured for S100 I/O communication in AC 800M systems, the ABB CI856K01 (CI856 S100 I/O Communication Interface) provides the communication path between the AC 800M controller and S100 I/O racks. The CI856 connects to the CEX-Bus through the TP856 baseplate and requires no separate external power source.

    Hardware Specifications

    Parameter Specification
    Model CI856K01
    Base Model CI856
    Product ID 3BSE026055R1
    Brand ABB
    Product Type S100 I/O Communication Interface
    Communication Protocol ABB S100 I/O
    Controller Interface CEX-Bus
    Master or Slave Master
    Transmission Speed Not specified
    Line Redundancy No
    Module Redundancy No
    Hot Swap Yes
    HI Controller Compatibility Yes
    Maximum Units on CEX-Bus 12
    S100 I/O Rack Capacity Up to 5 racks per CI856
    I/O Boards per Rack Up to 20
    Connector 36-pin Miniribbon
    Baseplate TP856
    Power Source AC 800M processor unit via CEX-Bus
    24 VDC Consumption Typ. 120 mA
    Typical Power Consumption Approx. 2.88 W at 24 VDC
    Operating Temperature 0 to +55 deg C
    Storage Temperature -40 to +70 deg C
    Corrosion Protection G3 compliant to ISA 71.04
    Protection Class IP20 according to EN 60529 and IEC 529
    CE Marking Yes
    RoHS Compliance EU RoHS, UAE RoHS, CN RoHS
    WEEE Compliance Directive 2012/19/EU
    Width 59 mm
    Height 185 mm
    Depth 127.5 mm
    Weight Including Base 700 g

    CEX-Bus and S100 I/O Communication

    The CI856 exchanges S100 I/O data with the AC 800M controller through the CEX-Bus interface. The TP856 baseplate provides the mechanical mounting interface and houses the ribbon connector used for connection to S100 I/O rack bus extender boards.

    One CI856 can connect to up to five S100 I/O racks. Each rack can accommodate up to 20 I/O boards. Therefore, the supported architecture permits distributed S100 I/O expansion while retaining the controller-side CEX-Bus connection.

    The module receives its operating power from the AC 800M processor unit through the CEX-Bus. Consequently, the CI856 does not require a separate external power supply.

    The specified 36-pin Miniribbon connector provides the physical interface for the communication assembly. The TP856 baseplate also supports DIN-rail mounting for installation within the control cabinet.

    Frequently Asked Questions (FAQ)

    Q: How many S100 I/O racks can one CI856K01 support?
    A: One CI856K01 can connect to up to five S100 I/O racks, with each rack supporting up to 20 I/O boards.

    Q: Does the CI856K01 require an external power supply?
    A: No. The CI856 receives power from the AC 800M processor unit through the CEX-Bus. Its typical 24 VDC consumption is 120 mA.

    Q: What connector does the CI856K01 use for the CEX-Bus connection?
    A: The supplied specification identifies a 36-pin Miniribbon connector. The connector is housed through the TP856 baseplate assembly.

    Field Installation Guidelines

    1. Mount the TP856 baseplate on a suitable DIN rail inside the control cabinet.
    2. Install the CI856 communication interface on the TP856 baseplate according to the AC 800M hardware installation procedure.
    3. Connect the baseplate to the CEX-Bus using the specified system connection arrangement.
    4. Connect the TP856 ribbon interface to the S100 I/O rack bus extender boards.
    5. Route communication and power-related wiring separately from high-current switching and high-noise circuits where practical.
    6. Verify connector seating and mechanical retention before energizing the controller assembly.
    7. Maintain cabinet grounding and shielding practices specified by the AC 800M and S100 I/O installation documentation.
    8. Confirm that the installed rack count and I/O board count remain within the CI856 architecture limits.
    9. Check the cabinet operating temperature against the specified 0 to +55 deg C range.
    10. Inspect the installation for correct IP20 enclosure protection and adequate environmental control.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account