Honeywell CC-TCF901 9 Port Control Firewall IOTA Configured for FTE network control firewall connectivity in Honeywell Experion PKS platforms, the...
اقرأ المزيد
متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً
راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com
متاح 24/7 للاستفسارات والدعم
وصف
Honeywell CC-TCF901 9 Port Control Firewall IOTA
Configured for FTE network control firewall connectivity in Honeywell Experion PKS platforms, the Honeywell CC-TCF901 (CC-TCF901 9 Port Control Firewall IOTA) provides direct physical/electrical execution for Ethernet communication interfaces and 24 VDC power distribution between control equipment and the FTE supervisory network.
Hardware Specifications
Parameter
Specification
Model
CC-TCF901
Brand
Honeywell
Product Type
9 Port Control Firewall IOTA
Origin
USA
Weight
Not specified
Dimensions
Approx. 12.1 cm x 14.5 cm (mounting dimensions L x W)
Operating Temp
Not specified
Power Consumption
0.30 mA @ 24 VDC
Ethernet Interface
9 x RJ-45 connections
Network Function
Provides connection for eight FTE cables from in-cabinet controllers and Series CFIMs
Uplink Port
1 port for connection to FTE supervisory network
Power Distribution
24 VDC power distribution to control components
Fiber-Optic Compatibility
Supports CA-FSMx01 FTE Single Mode Fiber Module and CA-FMMx01 FTE Multi-Mode Fiber Module
Fiber Module Supply Rating
0.30 mA @ 24 VDC
Channel-to-Channel Isolation and FTE Network Interface
The CC-TCF901 is designed as an FTE (Fault Tolerant Ethernet) interface assembly within the Honeywell control system architecture. The module provides nine Ethernet RJ-45 connections, with eight ports allocated for in-cabinet controllers and Series CFIM connections and one uplink connection to the supervisory FTE network.
The unit supports fiber-optic interface expansion through compatible CA-FSMx01 single mode and CA-FMMx01 multi-mode fiber modules. The 24 VDC distribution interface supplies connected control network components while maintaining defined electrical separation between communication paths.
For process control installations, Honeywell network interface assemblies are commonly integrated with distributed control system components requiring structured Ethernet communication. Signal segregation and channel-to-channel isolation practices should be maintained during system design to minimize communication interference.
Frequently Asked Questions (FAQ)
Q: How many Ethernet connections are available on the CC-TCF901? A: The CC-TCF901 provides nine RJ-45 Ethernet connections. Eight ports connect to in-cabinet controllers and Series CFIMs, while the ninth port provides the FTE supervisory network uplink.
Q: Does the CC-TCF901 directly support fiber-optic communication? A: The CC-TCF901 supports fiber-optic connectivity through compatible CA-FSMx01 FTE Single Mode Fiber Modules and CA-FMMx01 FTE Multi-Mode Fiber Modules.
Q: What power supply is required for the CC-TCF901? A: The module requires a 24 VDC supply and provides 24 VDC power distribution for connected control components. The specified supply rating is 0.30 mA @ 24 VDC.
Field Installation Guidelines
Install the CC-TCF901 on the designated control cabinet mounting surface according to Honeywell system installation requirements.
Verify that the 24 VDC supply polarity and grounding connections comply with the cabinet power distribution design.
Maintain separation between Ethernet communication cables and high-voltage power conductors to reduce electrical interference.
Use appropriate shield grounding practices for Ethernet and fiber conversion assemblies where applicable.
Confirm RJ-45 cable routing and port assignments before commissioning the FTE network connection.
Inspect fiber module installation points and ensure optical interfaces remain protected from contamination during field installation.
تحديد
rtl">
المزايا
موثوقية عالية في البيئات الصناعية
يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية