أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Bently Nevada 3500/15 114M5329-01 High Voltage DC Power Supply Module

Bently Nevada 3500/15 114M5329-01 High Voltage DC Power Supply Module

شكل المنتج

Bently Nevada 3500/15 114M5329-01 High Voltage DC Power Supply Module The Bently Nevada 3500/15 114M5329-01, also cataloged as the 3500/15 High Voltage... اقرأ المزيد

رمز المنتج: 3500/15 114M5329-01
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 3500/15 114M5329-01 High Voltage DC Power Supply Module

    The Bently Nevada 3500/15 114M5329-01, also cataloged as the 3500/15 High Voltage DC Power Supply Module, operates as a regulated power conversion unit for DC bus distribution within the 3500 Machinery Monitoring Rack System. It converts 88 to 140 VDC input into stabilized rack-level supply rails and maintains continuous module power delivery under redundant or single-supply configurations.

    Configured for DC power conditioning in 3500 rack architecture, the Bently Nevada 3500/15 114M5329-01 (3500/15 High Voltage DC Power Supply Module) provides direct electrical execution through regulated conversion, load sharing, and controlled redundancy switching.

    Hardware Specifications

    Parameter Specification
    Model 3500/15 114M5329-01
    Brand Bently Nevada
    Origin USA
    Weight 1.14 kg
    Dimensions 5.1 × 25.2 × 12 cm
    Operating Temp -30 deg C to +65 deg C
    Power Consumption Max 194 W
    Input Voltage 88 to 140 VDC
    Input Frequency 47 to 63 Hz
    Output Current Up to 2.5 A
    Redundancy Dual supply operation supported
    Hot-Swap Capability Supported with parallel supply present

    Redundant Power Bus Regulation and Hot-Swap Control

    The module implements DC bus regulation across parallel supply configurations, maintaining controlled current sharing between primary and backup units. During redundancy operation, load transfer occurs without interruption of rack backplane voltage. Hot-swap insertion and removal are supported only when at least one active supply maintains stable output, preventing transient collapse of downstream monitoring modules.

    Frequently Asked Questions (FAQ)

    Q: Can the 3500/15 114M5329-01 be inserted or removed under load?
    A: Yes. Hot-swap is supported when at least one redundant supply maintains stable rack power.

    Q: How is redundancy handled between two power supplies?
    A: The supplies operate in parallel with load sharing and automatic backup takeover upon primary degradation.

    Q: What happens during undervoltage conditions at the input stage?
    A: The module continues regulated output until internal thresholds trigger protective shutdown of conversion stages.


    Field Installation Guidelines

    Install the module only in designated 3500 rack power slots. Verify correct polarity and voltage range before energizing the input stage. Ensure redundant units are matched and properly seated for load sharing operation. Maintain chassis grounding continuity to reduce circulating currents. Do not perform insertion or removal unless at least one active supply maintains rack voltage stability.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account