    وصف

    Bently Nevada 3300/01-01-00 System Monitor Module

    Configured for centralized rack coordination and signal distribution in the Bently Nevada 3300 Machinery Protection System, the Bently Nevada 3300/01-01-00 (3300/01 System Monitor Module) provides direct physical and electrical execution of monitoring, alarm management, and transducer interfacing tasks.

    Suffix Breakdown & Model Matrix

    Suffix

    Definition

    3300/01

    System Monitor Module base model

    -01

    Standard agency approvals (CSA/NRTL/C)

    -00

    No modification / standard interface option

    Hardware Specifications

    Parameter

    Specification

    Model Brand

    Bently Nevada

    Origin

    United States

    Weight

    0.55 kg

    Dimensions

    Standard 3300 rack slot width

    Operating Temp

    0 degC to +65 degC

    Storage Temp

    -40 degC to +85 degC

    Relative Humidity

    95% non-condensing

    Power Consumption

    -24 VDC via backplane

    Output Impedance

    100 ohm buffered Keyphasor outputs

    Eddy-Current Probe Scaling and Gap Voltage Validation

    The 3300/01-01-00 supports precise eddy-current probe scaling through linearized target calibration against API 670 requirements. Gap voltage validation targets a nominal -10 VDC bias under static conditions, ensuring transducer health prior to rotor dynamics measurement. Signal crosstalk suppression is maintained between channels via isolated return paths and screened cabling practices within the rack assembly.

    Frequently Asked Questions

    Q: Does the 3300/01-01-00 support hot-swap replacement without rack power-down?

    A: No. Backplane power must be removed before removal or insertion to prevent damage to connectors and maintain signal integrity.

    Q: What is the alarm inhibit duration during power-up?

    A: The internal Power-up Inhibit function suppresses alarm outputs for approximately 2 seconds after supply stabilization.

    Q: Can the buffered Keyphasor outputs drive multiple diagnostic devices simultaneously?

    A: Yes, provided total load impedance does not fall below 10 kohm per output to avoid signal attenuation.

    Field Installation Guidelines

    Mount the module into the designated leftmost slot of the 3300 rack to ensure correct backplane addressing. Use shielded twisted-pair cable for all transducer wiring, terminating shields at the rack ground busbar. Verify gap voltage at each proximity probe before final rack commissioning. Ensure all dry-contact inhibit wiring uses adequately rated control cables segregated from high-voltage conductors. Maintain minimum clearance around ventilation slots to prevent thermal accumulation.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account