Bently Nevada 200200-03-03-05 Temperature Interface Modules

Bently Nevada 200200-03-03-05 Temperature Interface Modules

شكل المنتج

Bently Nevada 200200-03-03-05 Trendmaster proTIM-R Temperature Interface Module The Bently Nevada 200200-03-03-05, also cataloged as the 200200 proTIM-R Temperature Interface... اقرأ المزيد

رمز المنتج: 200200-03-03-05
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 200200-03-03-05 Trendmaster proTIM-R Temperature Interface Module

    The Bently Nevada 200200-03-03-05, also cataloged as the 200200 proTIM-R Temperature Interface Module, operates as a dedicated hardware component for dual-channel RTD temperature signal acquisition within the Trendmaster distributed condition monitoring system.

    Hardware Specifications

    Parameter Specification
    Model 200200-03-03-05
    Brand Bently Nevada
    Product Series Trendmaster 200 Series proTIM-R
    Module Type Processor Transducer Interface Module
    Origin United States
    Weight Approx. 0.77 lbs (349 grams)
    Dimensions Approx. 11.6 cm x 2.5 cm x 2.0 cm
    Input Channels 2 independent temperature input channels
    Sensor Input Type 2-wire or 3-wire Platinum RTD (Pt100 typical)
    Mounting Method 35 mm DIN rail mounting
    Signal Processing Analog signal conditioning and digital conversion
    Electrical Isolation Isolated temperature input channels
    System Interface Trendmaster data highway communication

    Rotor Temperature Signal Processing and Mechanical Monitoring Features

    The Bently Nevada 200200-03-03-05 processes RTD temperature signals through dedicated input conditioning circuits before transferring measurement data to the Trendmaster monitoring network. Moreover, the isolated channel design reduces ground loop influence during temperature measurement in distributed machinery monitoring installations.

    This proTIM-R module supports thermal condition measurement for rotating equipment components through Platinum RTD inputs. In addition, the module architecture follows Bently Nevada monitoring practices that maintain measurement integrity for machinery diagnostics, including sensor signal scaling and verification methods used in condition monitoring systems.

    The module operates within the Trendmaster platform where temperature data contributes to machinery protection analysis. Furthermore, the hardware design supports separation between field sensor wiring and system communication paths to reduce signal interference.

    Frequently Asked Questions

    Q: What type of sensors can the Bently Nevada 200200-03-03-05 accept?
    A: The module accepts 2-wire or 3-wire Platinum RTD temperature sensors, typically configured with Pt100 resistance elements.

    Q: Does the 200200-03-03-05 provide isolated temperature inputs?
    A: Yes. The module provides isolated temperature input channels to reduce electrical interference and ground loop effects between field devices.

    Q: Can this module be installed on a standard industrial DIN rail?
    A: Yes. The module uses a 35 mm DIN rail mounting configuration for installation inside industrial control cabinets.

    Field Installation Guidelines

    Install the 200200-03-03-05 module on a properly secured 35 mm DIN rail inside an enclosure that meets the environmental requirements of the installation location.

    Connect RTD sensor wiring according to the selected 2-wire or 3-wire configuration. Use shielded instrumentation cable where required, and terminate cable shields according to the plant grounding standard to minimize electrical noise.

    Separate RTD signal cables from high-voltage power conductors, motor cables, and switching circuits. Additionally, verify terminal connections before system startup to prevent incorrect temperature readings caused by wiring errors.

    Confirm communication wiring between the proTIM-R module and the Trendmaster network before commissioning. Therefore, perform signal verification using the system configuration software to validate channel assignment and temperature measurement response.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية