أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Bently Nevada 1800/20-XX-90-02-00 Thrust Position Proximity Transmitter

Bently Nevada 1800/20-XX-90-02-00 Thrust Position Proximity Transmitter

شكل المنتج

Bently Nevada 1800/20-XX-90-02-00 Thrust Position Proximity Transmitter The Bently Nevada 1800/20-XX-90-02-00, also cataloged as the 1800/20 Thrust Position Proximity Transmitter,... اقرأ المزيد

رمز المنتج: 1800/20-XX-90-02-00
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 1800/20-XX-90-02-00 Thrust Position Proximity Transmitter

    The Bently Nevada 1800/20-XX-90-02-00, also cataloged as the 1800/20 Thrust Position Proximity Transmitter, operates as a dedicated hardware component for converting eddy-current probe signals into 4-20 mA position monitoring outputs within machinery protection systems.

    Hardware Specifications

    Parameter Specification
    Model 1800/20-XX-90-02-00
    Brand Bently Nevada
    Product Type Thrust Position / Proximity Transmitter
    Origin USA
    Weight Approx. 0.5 kg
    Dimensions Approx. 75 mm x 115 mm x 100 mm
    Operating Temp -40 deg C to +85 deg C
    Power Consumption 24 VDC supply input
    Measurement Type Axial displacement / proximity position monitoring
    Sensing Technology Eddy-current non-contact measurement
    Input Interface Proximity probe and extension cable connection
    Signal Output 4-20 mA current loop output
    Accuracy +/-0.5% of full scale
    Repeatability +/-0.2% of full scale
    Maximum Load Resistance 750 ohms at 24 VDC
    Mounting Type DIN rail or panel mounting
    Humidity Rating Up to 93% non-condensing
    Certifications CE, UL, CSA depending on configuration

    Eddy-Current Probe Scaling and Rotor Dynamics Monitoring

    The 1800/20 transmitter processes displacement signals generated by eddy-current proximity probes and converts probe voltage characteristics into proportional engineering outputs. The signal chain is configured around probe gap measurement, linearization, and 4-20 mA transmission for thrust position monitoring.

    During installation, the probe gap voltage is commonly validated against Bently Nevada measurement practices, including verification of approximately -10 VDC target gap conditions for compatible eddy-current systems. Correct scaling between probe output voltage and mechanical position is required for accurate rotor axial movement analysis.

    The transmitter architecture supports monitoring of rotor dynamics parameters where axial shaft movement, thrust bearing position, and mechanical displacement trends are evaluated through continuous analog measurement.

    Frequently Asked Questions

    Q: What type of sensor input does the 1800/20 transmitter accept?
    A: The unit accepts signals from compatible eddy-current proximity probes and extension cable assemblies used for non-contact displacement measurement.

    Q: Does the 1800/20 require a Bently Nevada monitor rack for operation?
    A: The transmitter provides a direct 4-20 mA output signal, allowing connection to PLC, DCS, or other analog input systems without requiring a separate monitor rack.

    Q: What installation factors affect measurement accuracy?
    A: Probe mounting position, cable routing, electromagnetic interference, probe gap setting, and proper signal grounding affect measurement accuracy.

    Field Installation Guidelines

    • Install the transmitter in a location protected from excessive vibration, moisture, and contamination.
    • Connect the eddy-current probe and extension cable according to the approved wiring configuration.
    • Maintain separation between sensor signal wiring and high-voltage power cables to reduce electrical interference.
    • Apply proper shield termination and grounding practices according to plant instrumentation standards.
    • Verify probe gap voltage and transmitter output scaling before placing the monitoring loop into service.
    • Confirm the 4-20 mA loop signal corresponds with the expected mechanical displacement range.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account