أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

Allen Bradley 1769sc-IT6I Isolated Thermocouple Input Module

Allen Bradley 1769sc-IT6I Isolated Thermocouple Input Module

شكل المنتج

Allen Bradley 1769sc-IT6I Isolated Thermocouple Input Module Configured for isolated thermocouple signal acquisition in Allen Bradley SLC controller platforms, the... اقرأ المزيد

رمز المنتج: 1769sc-IT6I
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Allen Bradley 1769sc-IT6I Isolated Thermocouple Input Module

    Configured for isolated thermocouple signal acquisition in Allen Bradley SLC controller platforms, the Allen Bradley 1769sc-IT6I (1769sc-IT6I Isolated Thermocouple Input Module) provides direct electrical measurement of thermocouple and millivolt signals through six individually isolated input channels.

    Hardware Specifications

    Parameter Specification
    Model 1769sc-IT6I
    Brand Allen Bradley / Spectrum Controls
    Origin USA
    Product Type Isolated Thermocouple Input Module
    Product Line CompactLogix compatible I/O module
    Series SLC
    Module Type Thermocouple / mV input module
    Weight 2.00 lbs (0.91 kg)
    Power Consumption 150 mA at 5 V maximum; 35 mA at 24 V maximum
    Input Channels Six individually isolated channels
    Input Types Thermocouple and millivolt input
    Compatible Thermocouple Types J, K, T, E, R, B, S, N, C, and L
    Compatible mV Signals +/-50 mV and +/-100 mV
    Resolution 16 bits
    Input Impedance Greater than 1 Mohm
    Channel Isolation 125 VAC channel-to-channel; 125 VAC field wiring-to-backplane; 125 VAC field wiring-to-chassis ground
    Input Overvoltage Protection +/-35 VDC continuous
    Input Filters 4.17 Hz, 10 Hz, 16.7 Hz, 19.6 Hz, 62 Hz, and 470 Hz
    Channel Update Time 0.244 sec, 0.104 sec, 0.064 sec, 0.055 sec, 0.020 sec, and 0.006 sec
    Backplane Current Required 150 mA at 5 V maximum; 35 mA at 24 V maximum
    Certifications UL/cUL Listed, ANSI ISA 12.12.01 Class I Div 2 Groups ABCD, CE
    Recommended Cable Shielded twisted-pair thermocouple extension wire for TC inputs; Belden 8761 or equivalent for mV inputs
    UPC 850637004151

    PLC I/O Backplane Integration and Signal Processing

    The 1769sc-IT6I integrates with Allen Bradley controller platforms through the SLC architecture and processes thermocouple and millivolt input signals. The module provides six independent isolated measurement channels, which reduce electrical interference between field signals and controller-side circuits.

    The module supports I/O density scaling through six configurable input channels. Additionally, the 16-bit conversion resolution enables the controller system to process low-level thermocouple and millivolt signals for temperature measurement applications.

    Frequently Asked Questions

    Q: Which thermocouple types does the 1769sc-IT6I support?
    A: The module supports Type J, K, T, E, R, B, S, N, C, and L thermocouple sensors. It also accepts +/-50 mV and +/-100 mV input signals.

    Q: Does the 1769sc-IT6I provide channel isolation?
    A: Yes. The module provides individual channel isolation with 125 VAC isolation ratings between channels, field wiring and backplane, and field wiring and chassis ground.

    Q: What power load does the module place on the controller backplane?
    A: The module requires a maximum of 150 mA at 5 V and 35 mA at 24 V from the system power supply.

    Field Installation Guidelines

    Install the 1769sc-IT6I according to the controller platform installation requirements and maintain correct module orientation within the I/O assembly.

    Use shielded twisted-pair thermocouple extension wire for thermocouple connections. For millivolt inputs, use Belden 8761 cable or an equivalent shielded cable type.

    Route thermocouple and millivolt signal wiring separately from high-voltage power conductors and switching devices to reduce electrical noise coupling. Connect cable shields according to the control system grounding practice and avoid multiple grounding points that can introduce ground loops.

    Verify sensor polarity, input channel configuration, and thermocouple type settings before placing the controller system into operation. Confirm field wiring insulation and terminal connections before applying system power.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account