Bently Nevada 330905-00-18-05-02-05 3300 NSv Proximity Probe The Bently Nevada 330905-00-18-05-02-05, also cataloged as the 330905 3300 NSv Proximity Probe,... اقرأ المزيد

رمز المنتج: 330905-00-18-05-02-05
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 330905-00-18-05-02-05 3300 NSv Proximity Probe

    The Bently Nevada 330905-00-18-05-02-05, also cataloged as the 330905 3300 NSv Proximity Probe, operates as a dedicated hardware component for non-contact shaft displacement measurement within the Bently Nevada 3300 NSv Transducer System.

    Hardware Specifications

    Parameter Specification
    Model 330905-00-18-05-02-05
    Brand Bently Nevada
    Product Type 3300 NSv Proximity Probe
    Origin USA
    Weight 0.14 kg
    Dimensions Estimated shipping size: 1.8 x 1.6 x 63 cm
    Thread Type M10 x 1 metric thread
    Armor Type Without armor
    Unthreaded Length 0 mm
    Overall Case Length 180 mm
    Total Length 0.5 meter (20 in)
    Connector Type Miniature coaxial ClickLoc connector
    Cable Type Standard cable
    Agency Approval Multiple Approvals
    Application Interface Eddy-current displacement measurement system

    Eddy-Current Probe Scaling and Rotor Dynamics Characteristics

    The Bently Nevada 330905-00-18-05-02-05 uses eddy-current sensing technology to measure shaft displacement without mechanical contact. The probe generates an electromagnetic field at the sensing tip and converts shaft position changes into electrical output signals through the associated proximity transducer system.

    Additionally, the 3300 NSv probe design supports rotor dynamics monitoring applications by providing displacement feedback for vibration analysis and shaft position evaluation. Therefore, correct probe installation, target material compatibility, and cable routing directly influence measurement stability.

    The probe system requires proper gap voltage validation during commissioning. Engineers typically verify the probe operating gap against Bently Nevada proximity system requirements, including standard gap voltage targets around -10 VDC for correct linear measurement operation.

    The miniature coaxial ClickLoc connector improves field connection consistency, while the compact M10 x 1 threaded housing allows installation in locations with limited mechanical clearance.

    Frequently Asked Questions

    Q: What measurement technology does the 330905-00-18-05-02-05 use?
    A: The probe uses eddy-current technology to detect shaft displacement by measuring changes in the electromagnetic field between the probe tip and the rotating target.

    Q: Does this model include an armored construction?
    A: No. The 330905-00-18-05-02-05 uses an unarmored configuration with a standard cable and miniature coaxial ClickLoc connector.

    Q: What installation factors affect probe measurement accuracy?
    A: Engineers should verify probe gap setting, target surface condition, cable routing, shielding practices, and connector installation to maintain accurate displacement signals.

    Field Installation Guidelines

    Install the Bently Nevada 330905-00-18-05-02-05 probe using the specified M10 x 1 mounting thread and maintain proper mechanical alignment with the monitored shaft target.

    Route the probe cable away from high-current power conductors and strong electromagnetic interference sources. Use appropriate shielding and grounding methods according to the system installation requirements.

    Before operation, verify the probe gap voltage and confirm that the connected monitoring channel receives a stable displacement signal. Inspect the miniature coaxial ClickLoc connector for correct engagement and secure mechanical connection.

    Avoid excessive cable bending near the connector area because mechanical stress can affect signal integrity. Confirm the installed probe length and clearance requirements before final equipment startup.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews