أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

330880-28-40-058-01-02 PROXPAC XL Proximity Sensors Bently Nevada

330880-28-40-058-01-02 PROXPAC XL Proximity Sensors Bently Nevada

شكل المنتج

Bently Nevada 330880-28-40-058-01-02 PROXPAC XL Proximity Transducer Assembly The Bently Nevada 330880-28-40-058-01-02, also cataloged as the 330880 PROXPAC XL Proximity... اقرأ المزيد

رمز المنتج: 330880-28-40-058-01-02
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 330880-28-40-058-01-02 PROXPAC XL Proximity Transducer Assembly

    The Bently Nevada 330880-28-40-058-01-02, also cataloged as the 330880 PROXPAC XL Proximity Transducer Assembly, operates as a dedicated hardware component for non-contact shaft displacement measurement and vibration monitoring within Bently Nevada TSI monitoring systems.

    Hardware Specifications

    Parameter Specification
    Model 330880-28-40-058-01-02
    Brand Bently Nevada
    Product Type PROXPAC XL Proximity Transducer Assembly
    Probe Type 3300 XL 8 mm eddy-current proximity probe
    Probe Diameter 8 mm
    Measurement Function Shaft vibration, axial position, and rotational speed measurement
    Linear Range 2.0 mm (80 mils)
    Typical Measurement Range 0.25 mm to 2.25 mm (10 mils to 90 mils)
    Incremental Scale Factor 7.87 V/mm (200 mV/mil) +/-5%
    Frequency Response 0 Hz to 10 kHz (+0, -3 dB)
    Power Supply Voltage -17.5 VDC to -26 VDC without barriers; -23 VDC to -26 VDC with barriers
    Output Impedance 50 Ohm nominal
    Housing Material Glass and conductive fiber-reinforced Polyphenylene Sulfide (PPS)
    Protection Rating IP66 / Type 4X
    Operating Temp Probe and housing: -51 deg C to +177 deg C; integrated Proximitor: -51 deg C to +100 deg C
    Humidity Range 0 to 95% non-condensing
    Impact Resistance Up to 7 Joules at ambient temperature
    Standoff Length 4.0 inches (102 mm)
    Probe Penetration 5.8 inches (147 mm)
    Mounting Thread 3/4-14 NPT
    Conduit Configuration One 3/4-14 NPT fitting and two plugs
    Weight Approx. 1.0 kg to 1.5 kg depending on configuration
    Dimensions Configuration dependent; includes 4.0 inch standoff and 5.8 inch probe penetration
    Power Consumption Supplied through integrated Proximitor electrical circuit

    Eddy-Current Probe Scaling and Rotor Dynamics Monitoring

    The 330880-28-40-058-01-02 uses a 3300 XL 8 mm eddy-current probe structure to convert shaft displacement into proportional voltage output. Therefore, the system maintains a calibrated scale factor of 200 mV/mil for vibration and position analysis.

    The integrated Proximitor performs signal conditioning inside the PPS housing. As a result, the assembly removes the external extension cable normally required between a conventional probe and signal conditioner. This configuration reduces installation complexity and improves mechanical protection.

    For TSI applications, the system supports rotor dynamics analysis by providing stable shaft displacement signals. In addition, technicians can validate probe gap conditions through gap voltage measurement, with typical Bently Nevada installations targeting approximately -10 VDC for correct probe positioning.

    Frequently Asked Questions

    Q: Does the 330880-28-40-058-01-02 require an external extension cable?
    A: No. The PROXPAC XL design integrates the Proximitor directly into the housing, eliminating the external probe-to-sensor extension cable.

    Q: What measurement principle does this assembly use?
    A: The assembly uses an eddy-current proximity measurement principle to detect shaft displacement without physical contact.

    Q: What installation factors affect measurement accuracy?
    A: Proper probe mounting, correct gap voltage adjustment, suitable grounding practices, and controlled cable routing conditions affect signal quality.

    Field Installation Guidelines

    • Install the 3/4-14 NPT mounting connection with sufficient mechanical engagement and verify thread sealing requirements according to site standards.
    • Position the probe tip according to the required shaft clearance and confirm the operating gap voltage before commissioning.
    • Route signal wiring away from high-current power cables to reduce electromagnetic interference.
    • Connect shielding according to plant grounding practices and avoid multiple ground paths that may introduce signal noise.
    • Verify the PPS housing condition before operation because mechanical damage can affect environmental protection performance.
    • Confirm the integrated Proximitor temperature limit before selecting the installation location.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account