Bently Nevada 3300/50-01-02-03-02 Tachometer Monitor The Bently Nevada 3300/50-01-02-03-02, also cataloged as the 3300/50 Tachometer Monitor, operates as a dedicated... اقرأ المزيد

رمز المنتج: 3300/50-01-02-03-02
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 3300/50-01-02-03-02 Tachometer Monitor

    The Bently Nevada 3300/50-01-02-03-02, also cataloged as the 3300/50 Tachometer Monitor, operates as a dedicated hardware component for shaft speed measurement, acceleration monitoring, and zero speed detection within the Bently Nevada 3300 Monitoring System.

    Hardware Specifications

    Parameter Specification
    Model 3300/50-01-02-03-02
    Brand Bently Nevada
    Origin USA
    Product Type Tachometer Monitor Module
    System Platform 3300 Machinery Protection System
    Input Type Proximity probe and magnetic pickup signals
    Input Channels Up to 2 transducer inputs with voting logic
    Input Impedance 10 kOhm nominal
    Speed Measurement Range 1 to 99,999 rpm
    Rotor Acceleration Range -9,999 to 9,999 rpm/min
    Zero Speed Detection Typically below 100 rpm
    Accuracy Within +/-1 rpm for speed display; within +/-20 rpm/min for acceleration display at 25 deg C
    Buffered Output Front panel coaxial output per transducer channel
    Buffered Output Impedance 100 Ohm
    Recorder Output 4-20 mA DC proportional output
    Display Type 7-segment LCD display
    Alarm Functions Alert and Danger adjustable setpoints
    Relay Operation Normally energized/de-energized, latching or non-latching modes
    Power Consumption 2.5 Watts nominal
    Operating Temp 0 deg C to +65 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity Up to 95%, non-condensing

    TSI Signal Processing and Rotor Dynamics Features

    The Bently Nevada 3300/50-01-02-03-02 processes rotational speed signals from eddy-current probes or magnetic pickups and converts pulse inputs into shaft speed and acceleration values. The module applies tachometer signal conditioning to maintain measurement accuracy during changing rotor operating conditions.

    Furthermore, the module supports eddy-current probe scaling and gap voltage validation principles used in Bently Nevada machinery monitoring systems. The transducer interface evaluates input signal amplitude and operating point conditions to maintain correct measurement conversion.

    The module architecture supports rotor dynamics monitoring by tracking speed variation, acceleration behavior, and zero speed conditions. Additionally, the buffered outputs provide isolated access for external diagnostic equipment while maintaining front panel signal availability.

    Frequently Asked Questions

    Q: Does the 3300/50-01-02-03-02 support dual transducer inputs?
    A: Yes. The module accepts up to two transducer inputs and uses internal voting logic to reduce false trip conditions caused by individual signal disturbances.

    Q: What output signal does the recorder interface provide?
    A: The module provides a proportional 4-20 mA DC recorder output for connection to external PLC, DCS, or data acquisition systems.

    Q: Can the module monitor zero speed conditions?
    A: Yes. The tachometer function supports zero speed monitoring applications and typically operates below 100 rpm for low-speed detection.

    Field Installation Guidelines

    Install the 3300/50-01-02-03-02 module inside the designated 3300 rack slot according to the system configuration requirements.

    Use shielded signal wiring for proximity probe and magnetic pickup connections. Connect cable shields according to the plant grounding standard to reduce electromagnetic interference.

    Maintain proper separation between tachometer signal cables and high-current power wiring. Avoid routing sensor cables near motor feeders, variable frequency drive outputs, or switching power sources.

    Verify transducer polarity, signal amplitude, and mechanical target condition before commissioning. For eddy-current probe installations, confirm the probe gap voltage and scaling parameters match the configured monitoring range.

    Check relay logic configuration, alarm setpoints, and 4-20 mA output scaling before placing the machinery protection channel into service.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account