3300/16-12-01-02-00-02-00 Vibration Monitor Module Bently Nevada

3300/16-12-01-02-00-02-00 Vibration Monitor Module Bently Nevada

شكل المنتج

Bently Nevada 3300/16-12-01-02-00-02-00 Vibration Monitor Module The Bently Nevada 3300/16-12-01-02-00-02-00 serves as the primary 3300/16 Dual Vibration Monitor utilized to execute dual-channel vibration measurement... اقرأ المزيد

رمز المنتج: 3300/16-12-01-02-00-02-00
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 3300/16-12-01-02-00-02-00 Vibration Monitor Module

    The Bently Nevada 3300/16-12-01-02-00-02-00 serves as the primary 3300/16 Dual Vibration Monitor utilized to execute dual-channel vibration measurement and alarm processing across the Bently Nevada 3300 Machinery Monitoring System platforms.

    The module processes two independent Proximitor-based vibration inputs, performs signal conditioning, and generates proportional analog outputs and relay-based alarm logic for each channel.

    Hardware Specifications

    Parameter Specification
    Model 3300/16-12-01-02-00-02-00
    Brand Bently Nevada
    Origin USA
    Dimensions 3300 rack module standard form factor
    OperatingTemp 0 degC to 65 degC
    PowerConsumption 7.5 W nominal
    Input Type Dual channel Proximitor transducer inputs
    Full Scale Range 0 to 5 mils peak-to-peak (Option 12)
    Transducer Compatibility 3300 8 mm, 3300XL 8 mm, 7200 5 mm/8 mm systems
    Output Signal 4-20 mA or 1-5 VDC recorder outputs
    Alarm Function Independent Alert and Danger per channel
    Relay Type Hermetically sealed output relays
    Trip Multiply 2X trip multiply function
    Frequency Response 10 Hz to 1 kHz (-3 dB)
    Accuracy +/-0.5% of full scale at 25 degC

    Eddy Current Probe Scaling and Signal Integrity Behavior

    Configured for mechanical displacement conversion using eddy-current proximity systems, the Bently Nevada 3300/16 processes raw gap voltage variations typically centered around negative DC bias levels near -10 VDC excitation reference conditions. The internal signal chain applies linear scaling to convert probe gap modulation into engineering units of vibration amplitude (mils or micrometers).

    Cross-talk suppression is implemented at the channel isolation stage to reduce electrical interference between adjacent monitoring paths within the 3300 backplane architecture. This ensures stable amplitude tracking during high-density rack operation where multiple vibration channels coexist.

    Frequently Asked Questions

    Q: Can the 3300/16 module channels operate independently during a single channel fault condition?
    A: Yes. Each channel is electrically isolated with independent signal conditioning and alarm logic execution. A failure in one channel does not interrupt the second channel processing path.

    Q: What is the behavior of trip multiply activation during overspeed conditions?
    A: The trip multiply function temporarily scales alarm setpoints by a factor of 2. It is implemented at the alarm comparison stage without altering raw vibration signal scaling.

    Q: Does the module support hot-swap replacement under powered rack conditions?
    A: The module is designed for rack-based insertion; however, removal or insertion under power may induce transient signal interruption on connected channels and is not intended for continuous monitoring operation.


    Field Installation Guidelines

    The module must be installed into a compatible Bently Nevada 3300 rack slot with full backplane seating engagement. Ensure that all Proximitor sensor cabling is routed with controlled impedance and separated from high-voltage switching conductors.

    Shield termination should be grounded at a single rack-side point to prevent ground loop formation. Maintain consistent channel labeling alignment between field wiring terminals and module channel numbering.

    Verify that external barrier configurations (if used) are matched to intrinsic safety requirements before energizing sensor loops. After installation, perform zero-state validation to confirm stable gap voltage baseline and absence of channel drift.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية