Bently Nevada 200200-02-02-CN ProTIM-R DIN Rail Mount Module Configured for dual thermocouple signal conditioning in the Trendmaster Pro online condition...
اقرأ المزيد
متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً
راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com
متاح 24/7 للاستفسارات والدعم
وصف
Bently Nevada 200200-02-02-CN ProTIM-R DIN Rail Mount Module
Configured for dual thermocouple signal conditioning in the Trendmaster Pro online condition monitoring system, the Bently Nevada 200200-02-02-CN (200200 ProTIM-R DIN Rail Mount Module) provides direct physical and electrical execution for temperature measurement channels.
Hardware Specifications
Parameter
Specification
Model
200200-02-02-CN
Brand
Bently Nevada
Origin
United States
Operating Temp
-25 deg C to +85 deg C
Power Consumption
Not specified
Product Type
Processor Transducer Interface Module (ProTIM-R)
System Platform
Trendmaster Pro Online Condition Monitoring System
Mounting Type
DIN Rail Mount
Number of Channels
2 independent configurable channels
Channel AA Input
K-Type Thermocouple via 200125 temperature transducer
Channel BB Input
K-Type Thermocouple via 200125 temperature transducer
Process Voltage Input Range
+1 VDC to +5 VDC
Process Current Input Range
+4 mA to +20 mA
Temperature Measurement Range
-18 deg C to +204 deg C
Temperature Accuracy
+/-8 deg C including ProTIM-R, thermocouple, and lead wire error
Temperature Resolution
0.07 deg C
Maximum Lead Wire Length
6 meters
Maximum Temperature Ramp Rate
+/-0.5 deg C/min
OK Operating Range
-31 deg C to +213 deg C
Storage Temperature
-40 deg C to +100 deg C
Humidity Rating
100% condensing on exposed surfaces
Hazardous Area Approval
NEPSI and ATEX/IECEx option
Eddy-Current Signal Scaling and Temperature Channel Processing
The ProTIM-R module processes field transducer signals through dedicated input conditioning circuits. Moreover, the dual-channel architecture allows independent measurement handling for two temperature inputs connected through 200125 temperature transducers.
For Bently Nevada monitoring systems, signal integrity depends on correct sensor scaling and electrical validation. Therefore, installation procedures must maintain proper signal reference conditions and minimize interference from external wiring sources. The module supports isolated temperature inputs to reduce ground loop effects during distributed machinery monitoring applications.
Frequently Asked Questions
Q: What input devices are supported by the 200200-02-02-CN module? A: The module supports dual K-Type thermocouple inputs through 200125 temperature transducers. It processes two independent temperature measurement channels.
Q: Does the ProTIM-R module provide electrical isolation for temperature inputs? A: Yes. The temperature input channels include electrical isolation to reduce ground loop interference between field devices and monitoring equipment.
Q: What environmental limits apply to the thermocouple ProTIM-R variant? A: The operating temperature range is -25 deg C to +85 deg C, while storage temperature ranges from -40 deg C to +100 deg C.
Field Installation Guidelines
Install the 200200-02-02-CN module on a compatible DIN rail and verify mechanical engagement before connecting field wiring. Ensure thermocouple wiring follows correct polarity and maintains separation from high-voltage power conductors.
Moreover, apply suitable contact protection methods, including DC4 grease on connector contacts where specified, to reduce corrosion risks in exposed environments. Use proper cable routing practices to limit electromagnetic interference and avoid parallel runs with high-current cables.
Verify channel configuration before commissioning. Confirm thermocouple signal response, wiring continuity, and monitoring system communication status before placing the module into operational service.
تحديد
rtl">
المزايا
موثوقية عالية في البيئات الصناعية
يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية