أكثر من 100,000 قطعة من PLC وDCS وDrive وTSI وMRO متوفرة في المخزون. تعرف على المزيد

170180-01-05 | External Transducer I/O Modules Bently Nevada

170180-01-05 | External Transducer I/O Modules Bently Nevada

شكل المنتج

Bently Nevada 170180-01-05 FieldMonitor External Transducer I/O Module Configured for dual-channel transducer signal acquisition in the FieldMonitor system, the Bently... اقرأ المزيد

رمز المنتج: 170180-01-05
بلد المنشأ: USA

      100% أصلي وحقيقي

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      100% جديد تمامًا وجاهز للشحن

    هل تحتاج إلى مخزون كبير؟ تواصل معنا .

      دعم استرداد الأموال، خدمة 7X24 ساعة

    دعم استرداد الأموال، خدمة 7X24 ساعة، اتصل بنا .

      اتصل بنا: +86 135 995 07613

    متاح في أيام العمل من الساعة 9:00 صباحًا إلى 6:00 مساءً

      راسلنا عبر البريد الإلكتروني: sales2@industriaxplc.com

    متاح 24/7 للاستفسارات والدعم

    وصف

    Bently Nevada 170180-01-05 FieldMonitor External Transducer I/O Module

    Configured for dual-channel transducer signal acquisition in the FieldMonitor system, the Bently Nevada 170180-01-05 (170180 FieldMonitor External Transducer I/O Module) provides direct physical and electrical interface execution for -24 VDC Proximitor or accelerometer inputs. This module is also cataloged as Solar Part Number 1034549-80.

    Hardware Specifications

    Parameter Specification
    Model 170180-01-05
    Brand Bently Nevada
    Series FieldMonitor External Transducer I/O Module
    Product Type External Transducer I/O Module
    Origin USA
    Weight Approx. 0.60 lbs (272 g)
    Dimensions Approx. 3.1 cm x 19 cm x 12.8 cm
    Operating Temp -40 deg C to +85 deg C
    Power Consumption Approx. 20 mA input current
    Channel Configuration 2 independent channels
    Input Capacity Supports up to two transducer inputs
    Channel A Input -24 VDC Proximitor or accelerometer
    Channel B Input -24 VDC Proximitor or accelerometer
    Terminal Base Occupancy One FieldMonitor Terminal Base slot
    Output Signal Range 0 to 10 VDC
    Measurement Type Dynamic vibration and static position measurement
    Frequency Response 10 Hz to 10 kHz
    Accuracy +/- 1% of full scale
    Humidity Range 5% to 95% relative humidity, non-condensing
    EMC Compliance EN 50081-2, EN 50082-2

    Eddy-Current Probe Scaling and Gap Signal Processing

    The Bently Nevada 170180-01-05 processes proximity and accelerometer signals through two independent input channels. Therefore, each channel maintains separate signal conditioning paths for connected transducers.

    The module supports -24 VDC Proximitor operation and allows FieldMonitor systems to acquire vibration and displacement-related signals. In addition, eddy-current probe scaling functions maintain the relationship between probe output voltage and mechanical shaft position measurements.

    For proximity measurement applications, gap voltage validation uses the typical Bently Nevada -10 VDC target reference for probe operating condition verification. The module architecture supports accurate rotor dynamics monitoring by preserving vibration waveform characteristics and reducing signal interference between measurement channels.

    Frequently Asked Questions

    Q: How many transducer inputs can the Bently Nevada 170180-01-05 accept?
    A: The module provides two independent input channels and accepts up to two transducer inputs through Channel A and Channel B.

    Q: Can the 170180-01-05 support both Proximitor and accelerometer inputs?
    A: Yes. Each channel supports -24 VDC Proximitor or accelerometer signal inputs according to the configured measurement application.

    Q: Does the module require a dedicated FieldMonitor Terminal Base position?
    A: Yes. The 170180-01-05 occupies one slot within a FieldMonitor Terminal Base for mechanical installation and electrical connection.

    Field Installation Guidelines

    • Install the module only in a compatible FieldMonitor Terminal Base slot.
    • Verify channel configuration before connecting field transducers.
    • Use shielded instrumentation wiring for vibration and displacement signal connections.
    • Connect cable shields according to site grounding practices to reduce electrical noise.
    • Separate transducer signal wiring from high-current power cables and switching circuits.
    • Confirm Proximitor supply polarity before energizing the module.
    • Check sensor wiring continuity and insulation resistance before system startup.
    • Verify gap voltage readings after installation to confirm correct probe positioning.

    تحديد

    • rtl">

    المزايا

    • موثوقية عالية في البيئات الصناعية

    • يدعم التشغيل المستمر، متوافق مع أنظمة PLC/DCS الرئيسية

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    أرسل لنا رسالة!

    هل تحتاج إلى مخزون كبير؟ تواصل معنا.

    مجموعات قد تعجبك أيضًا

    المنتجات التي تمت مشاهدتها مؤخرًا

      Login

      نسيت كلمة السر؟

      ليس لديك حساب حتى الآن؟
      Create account