ABB menawarkan solusi otomasi industri untuk penggerak, sistem kontrol, dan robotika. Inventaris global kami memastikan akses cepat ke suku cadang yang sulit ditemukan. Kurangi waktu henti dan pertahankan produksi berkelanjutan dengan komponen ABB yang terverifikasi.
ABB
-
ABB ABB HESG447024R1 HEB67077-31B 70BT01C Bus Transmitter Module
DescriptionThe ABB HESG447024R1 (70BT01C) is a high-performance bus transmitter and isolation amplifier module designed specifically for the ABB PROCONTROL P distributed control system. This module functions as a critical interface between the main PROCONTROL control system and the PROCONTROL-PS protection system, enabling the seamless integration of protection signals into the P bus architecture.Features System Integration: Facilitates communication between PROCONTROL-PS protection systems and the main PROCONTROL P bus. Galvanic Isolation: Provides 1500 V DC isolation to ensure electrical safety and mitigate ground loop interference between disparate system segments. Signal Processing: Supports up to 32 binary or analog input signals, converting them into 32 compatible PROCONTROL P bus signals. Configuration: Configured via the Process Data Display System (PDDS) with nonvolatile storage in onboard EEPROM. High-Speed Communication: Supports deterministic remote bus communication for real-time process signal availability. Redundancy: Designed to support redundant communication architectures to enhance system reliability. ApplicationsThis module is widely utilized in large-scale industrial automation environments, including: Power Generation: Thermal, hydropower, and nuclear power plants for turbine control and protection. Metallurgical Industry: Automation of blast furnaces and monitoring of steel rolling lines. Petrochemical: Process monitoring in oil refining and chemical production. Manufacturing: Conveyor system monitoring and grinding machine control in cement and paper mills. Technical Specifications Model HESG447024R1 / HEB67077-31B / 70BT01C Manufacturer ABB Power Supply 24 V DC Power Consumption < 10 W Input Capacity Up to 32 binary/analog signals Isolation Voltage 1500 V DC Operating Temperature -20 degC to +60 degC Storage Temperature -40 degC to +85 degC Humidity 0 - 95 % RH (non-condensing) Installation Guidelines Safety First: Always disconnect power from the rack before inserting or removing the module to prevent electrical damage. Handling: This module contains sensitive electronic components; use proper ESD (Electrostatic Discharge) protection during handling. Mounting: Ensure the module is securely seated in the designated PROCONTROL P rack slot to maintain proper bus backplane contact. Environment: Install in a clean, dry environment within the specified temperature range. Ensure adequate ventilation to prevent heat buildup. Wiring: Use shielded cables for signal input to minimize EMI/RFI interference. Ensure proper grounding of the cable shields at the designated terminal points. FAQWhat is the primary function of the HESG447024R1?The HESG447024R1 acts as a bus transmitter and isolation amplifier, bridging the gap between the PROCONTROL-PS protection system and the main PROCONTROL P bus system.How is the module configured?Configuration is performed using the ABB PDDS (Process Data Display System). Users load marshalling and limit-value lists into the module's RAM, which can then be saved to the onboard nonvolatile EEPROM.Does this module support redundant systems?Yes, the module is designed to be compatible with redundant communication architectures, helping to prevent system-wide failures in the event of a single module fault.
$199.00 $99.00
-
ABB ABB AC 800M PM856AK01 STU3BSE069514R1 STU Processor Unit
ABB PM856AK01 STU Processor Unit The ABB PM856AK01 STU 3BSE069514R1, also cataloged as the PM856AK01 Processor Unit, provides CPU execution, communication handling, and I/O data processing functions within ABB AC 800M System 800xA controller platforms. Hardware Specifications Parameter Specification Model PM856AK01 STU Brand ABB Origin Sweden Product Type AC 800M Processor Unit Order Number 3BSE069514R1 Controller Platform AC 800M System Compatibility ABB System 800xA Processor Type MPC860 Clock Frequency 24 MHz Performance 0.46 ms per 1000 Boolean operations Memory 16 MB Application RAM Available 10.337 MB Firmware Storage 2 MB Flash PROM Redundancy No High Integrity No Power Supply 24 VDC (19.2 to 30 VDC) Power Consumption 180 mA typical / 300 mA maximum at 24 VDC Power Dissipation 4.32 W typical / 7.2 W maximum Backup Battery Lithium 3.6 V Ethernet Ports 2 x RJ45 Ethernet Standard IEEE 802.3 Ethernet Speed 10 Mbit/s Control Network Protocol MMS and IAC Serial Interfaces 2 x RS-232C COM3 Interface RS-232C with modem control signals, 75 to 19200 baud COM4 Interface Isolated RS-232C service port, 9600 baud ModuleBus Capacity Maximum 96 I/O modules CEX Bus Capacity Maximum 12 single CEX bus modules Applications per Controller 32 Programs per Application 64 Diagrams per Application 128 Tasks per Controller 32 Minimum Cycle Time Down to 1 ms Real-Time Clock Stability 100 ppm Operating Temp 0 to +55 deg C Storage Temp -40 to +70 deg C Relative Humidity 5 to 95 %, non-condensing Protection Class IP20 Dimensions 119 x 186 x 135 mm Weight Approximately 1.2 kg including base Industrial Control Communication and Firmware Compatibility The ABB PM856AK01 STU processor unit communicates with AC 800M control networks through dual Ethernet RJ45 interfaces. Additionally, the controller uses ModuleBus communication for S800 I/O expansion and supports CEX bus modules for external communication functions. The processor includes firmware storage through Flash PROM and executes Control Builder applications within the System 800xA environment. Furthermore, the controller architecture supports deterministic backplane bus communication velocity for PLC/DCS task execution and I/O density scaling through connected S800 I/O modules. The CPU board integrates the microprocessor, RAM memory, real-time clock, LED status indicators, INIT push button, and CompactFlash interface. Therefore, the module provides centralized execution and diagnostic functions for AC 800M controller configurations. Frequently Asked Questions Q: Does the ABB PM856AK01 STU support redundant processor operation?A: No. The PM856AK01 STU is a non-redundant AC 800M processor unit. Redundant controller architectures require compatible redundant processor models. Q: Which communication interfaces are available on the PM856AK01 STU?A: The processor provides two RJ45 Ethernet ports for Control Network communication and two RS-232C serial interfaces for service and communication functions. Q: How does the PM856AK01 STU connect to S800 I/O modules?A: The processor connects to S800 I/O modules through the ModuleBus interface and supports up to 96 I/O modules according to system configuration requirements. Field Installation Guidelines Install the PM856AK01 STU processor unit on the specified ABB AC 800M mounting base and DIN rail assembly. Verify the 24 VDC power supply wiring before energizing the controller. Connect Ethernet communication cables according to ABB Control Network topology requirements. Install ModuleBus termination components correctly when connecting S800 I/O modules. Maintain proper cable separation between communication wiring and high-voltage power conductors. Connect cable shields according to industrial grounding practices to reduce electromagnetic interference. Check CPU LED indicators during startup, operation, and fault diagnostics. Confirm that the installation environment complies with operating temperature, humidity, and IP20 enclosure requirements.
$199.00 $99.00
-
ABB ABB AC 800M PM867K01 3BSE076355R1 Processor Modules
ABB PM867K01 Processor Module The ABB 3BSE076355R1 PM867K01, also cataloged as the PM867K01 Processor Module, operates as a dedicated hardware component for CPU execution, communication management, and safety control processing within ABB AC 800M High Integrity and System 800xA platforms. Hardware Specifications Parameter Specification Model PM867K01 Article Number 3BSE076355R1 Brand ABB Product Type Processor Module System Platform AC 800M High Integrity / System 800xA Origin Sweden Processor Type MPC866 Clock Frequency 133 MHz Performance 0.09 ms per 1000 boolean operations Memory 64 MB RAM Available for Application 46.559 MB Firmware Storage 18 MB Flash PROM Flash Memory for Storage No Weight 1200 g including base Dimensions 119 mm width x 186 mm height x 135 mm depth Operating Temp 0 to +55 deg C Storage Temp -40 to +70 deg C Power Supply 24 V DC (19.2-30 V DC) Power Consumption 210 mA typical / 360 mA maximum at +24 V DC Power Dissipation 5.1 W typical / 8.6 W maximum Ethernet Interface 2 x RJ45 Ethernet ports, IEEE 802.3, 10 Mbit/s Serial Interfaces 2 x RS-232C ports COM3 Interface RS-232C, 75-19200 baud, RJ45, RTS-CTS support, non-isolated COM4 Interface RS-232C, 9600 baud, RJ45, optically isolated Control Network Protocol MMS and IAC Recommended Network Backbone 100 Mbit/s switched Ethernet Controller Applications Up to 32 applications Programs per Application Up to 64 Diagrams per Application Up to 128 Tasks per Controller Up to 32 Cycle Time Down to 1 ms CEX-Bus Communication Modules Maximum 12 CEX-Bus Supply Current Maximum 2.4 A Modulebus I/O Capacity Maximum 96 I/O modules with single CPU Redundant CPU I/O Capacity Maximum 84 I/O modules Built-in Backup Battery Lithium 3.6 V Real-Time Clock Stability 100 ppm Protection Class IP20 according to EN 60529 Firmware, Redundancy and Industrial Network Integration The PM867K01 CPU board integrates a microprocessor, RAM memory, real-time clock, LED indicators, INIT push button, and CompactFlash interface. The controller base plate provides two RJ45 Ethernet ports for Control Network communication and two RJ45 serial interfaces for configuration and service operations. The PM867K01 supports CPU redundancy functions when configured with compatible redundancy components. The redundancy architecture covers CPU modules, CEX-Bus communication paths, communication interfaces, and S800 I/O connections. The maximum controller switchover time in redundant configuration is 10 ms. ABB AC 800M High Integrity functionality requires the addition of an SM812 safety module and SIL-certified software. Therefore, the controller supports IEC 61508 and TÜV-certified safety execution environments for combined safety and process control applications. The module supports firmware flash compatibility within the AC 800M controller environment and provides deterministic backplane communication through the controller architecture. Furthermore, the I/O density scaling supports electrical and optical Modulebus clusters for distributed S800 I/O expansion. Compatibility applies to ABB 800xA version 6.0.2 and later systems. Frequently Asked Questions Q: Does the PM867K01 support CPU redundancy operation?A: Yes. The PM867K01 supports CPU redundancy configurations with compatible redundancy components covering CPU, CEX-Bus, communication interfaces, and S800 I/O connections. Q: What communication interfaces are integrated on the PM867K01 controller?A: The controller provides two Ethernet RJ45 ports for Control Network communication and two RS-232C RJ45 serial interfaces. COM3 supports modem control signals, while COM4 provides isolated configuration tool communication. Q: Is the PM867K01 suitable for SIL safety applications?A: Yes. High Integrity operation requires an SM812 module and SIL-certified software. The AC 800M High Integrity platform supports IEC 61508 and TÜV-certified safety control functions. Field Installation Guidelines Install the PM867K01 on the designated AC 800M controller base plate with correct mechanical alignment. Verify the 24 V DC power supply polarity before energizing the controller. Connect Ethernet communication cables to CN1 and CN2 ports according to Control Network topology requirements. Use shielded communication wiring where required by the industrial installation environment. Keep RS-232C service connections separated from high-voltage power wiring to reduce electromagnetic interference. Confirm CEX-Bus and Modulebus connections before commissioning connected communication modules and S800 I/O units. Maintain proper grounding practices for cabinet installation and follow ABB system installation documentation. Verify firmware and System 800xA compatibility before controller replacement or migration activities.
$199.00 $99.00
-
ABB ABB AC 800M PM856AK01 3BSE066490R1 Processor Unit Package
ABB PM856AK01 3BSE066490R1 Processor Unit Package The ABB PM856AK01 3BSE066490R1, also cataloged as the PM856A Processor Unit Package, operates as a dedicated hardware component for controller execution, memory management, and communication handling within ABB AC 800M System 800xA platforms. Hardware Specifications Parameter Specification Model PM856AK01 3BSE066490R1 Brand ABB Product Type Processor Unit Package Origin Sweden Weight 0.92 kg Dimensions 19 x 12 x 13.5 cm shipping size Processor Module PM856A CPU Baseplate TP830 CEX-Bus Terminator TB850 ModuleBus Terminator TB807 Memory Backup Battery 4943013-6 Controller Platform ABB AC 800M System Integration ABB System 800xA Tariff Code 8537101190 / 85389091 Industrial Control Bus and Firmware Compatibility The ABB PM856AK01 package supports AC 800M controller architecture through processor execution, backplane communication, and module interface management. The PM856A CPU performs application processing tasks while maintaining communication with connected I/O and controller modules. Furthermore, the package includes termination components for CEX-Bus and ModuleBus connections. These components maintain correct bus electrical conditions and support stable module communication within the controller configuration. The processor package supports ABB controller firmware environments designed for AC 800M hardware configurations. Firmware compatibility must be verified before replacement or system expansion. Frequently Asked Questions Q: What hardware components are included in the ABB PM856AK01 package?A: The package contains the PM856A processor unit, TP830 baseplate, TB850 CEX-Bus terminator, TB807 ModuleBus terminator, and 4943013-6 memory backup battery. Q: Does the PM856AK01 support redundant processor configurations?A: The PM856AK01 package is a processor hardware package for AC 800M systems. Redundancy capability depends on the selected controller configuration and supported system architecture. Q: What should be verified before installing the PM856AK01 processor package?A: Engineers should verify controller firmware compatibility, baseplate connections, bus termination placement, grounding conditions, and module addressing before commissioning. Field Installation Guidelines Install the PM856AK01 package on the specified ABB AC 800M controller mounting arrangement. Confirm that the TP830 baseplate is correctly seated before applying power. Install TB850 and TB807 terminators according to the configured CEX-Bus and ModuleBus topology. Route communication wiring separately from high voltage power cables to reduce electrical interference. Connect protective grounding according to industrial cabinet installation practices. Verify processor LED diagnostics after startup and confirm controller communication status. Replace the memory backup battery according to ABB maintenance procedures when required.
$199.00 $99.00
-
ABB PM858K01 3BSE082895R1 ABB AC 800M CPU Processors
ABB PM858K01 Processor Module The ABB 3BSE082895R1, also cataloged as the PM858K01 Processor Module, operates as a dedicated hardware component for application execution and control communication within ABB AC 800M controller platforms. The module integrates CPU processing, RAM memory, firmware storage, Ethernet communication, serial interfaces, and optional CPU redundancy support. Hardware Specifications Parameter Specification Model PM858K01 Article Number 3BSE082895R1 Brand ABB Product Type AC 800M Processor Module Origin Sweden Weight 1200 g including base Dimensions 119 mm W x 186 mm H x 135 mm D Operating Temp 0 to +55 deg C Storage Temperature -40 to +70 deg C Power Consumption 210 mA typical at +24 VDC, 360 mA maximum Power Supply 24 VDC (19.2-30 VDC) Power Dissipation 5.1 W typical, 8.6 W maximum Processor Type MPC866 Clock Frequency 33 MHz Application Memory 16 MB RAM Available for Application 7.147 MB Flash Memory Yes, 4 MB Flash PROM for firmware storage Boolean Operation Performance 0.36 ms per 1000 boolean operations CPU Redundancy Supported for CPU, CEX-Bus, communication interfaces and S800 I/O Redundancy Switch Over Time Maximum 10 ms Applications per Controller 32 Programs per Application 64 Diagrams per Application 128 Tasks per Controller 32 Application Cycle Time Down to 1 ms Ethernet Channels 2 Ethernet Interface IEEE 802.3 Ethernet, 10 Mbit/s, RJ45 female 8-pole Control Network Protocol MMS and IAC Recommended Network Backbone 100 Mbit/s switched Ethernet RS-232C Interfaces 2 ports COM3 Interface RS-232C, 75-19200 baud, full RTS-CTS support, non-isolated COM4 Interface RS-232C, 9600 baud, optically isolated, configuration tool connection Modulebus Capacity Maximum 96 I/O modules with single CPU configuration Modulebus Scan Rate 0-100 ms depending on I/O configuration CEX-Bus Communication Modules 12 CEX-Bus Supply Current Maximum 2.4 A Backup Battery Lithium 3.6 V Real-Time Clock Stability 100 ppm approximately 1 hour/year Event Queue Capacity Up to 3000 events per OPC client Firmware Flash Compatibility and Industrial Communication The PM858K01 uses firmware stored in Flash PROM memory and provides hardware resources for AC 800M control applications. The MPC866 processor executes controller tasks while maintaining communication through Ethernet and serial interfaces. The controller supports deterministic communication through the Control Network using MMS and IAC protocols. In addition, the Ethernet interface provides connection capability for engineering tools, operator systems, and controller-to-controller data exchange. The CPU architecture supports I/O density scaling through Modulebus communication. The controller can manage electrical and optical I/O clusters, while the CEX-Bus provides expansion capability for communication modules. Frequently Asked Questions Q: Does the PM858K01 support CPU redundancy configuration?A: Yes. The PM858K01 supports redundancy functions for CPU processing, CEX-Bus communication, communication interfaces, and S800 I/O systems. The specified redundancy switch-over time is maximum 10 ms. Q: What communication interfaces are integrated on the PM858K01 controller?A: The controller includes two RJ45 Ethernet ports for Control Network communication and two RJ45 RS-232C serial ports. COM3 provides general serial communication, while COM4 provides an isolated service tool connection. Q: What is the power requirement of the PM858K01?A: The controller requires a 24 VDC supply with an operating range of 19.2-30 VDC. Power consumption is 210 mA typical and 360 mA maximum at 24 VDC. Field Installation Guidelines Install the PM858K01 on the compatible AC 800M base plate using the slide and lock DIN rail mounting mechanism. Verify that the base plate Ethernet address label remains accessible for network identification. Connect the Ethernet ports using industrial Ethernet cabling with proper separation from high-voltage power conductors. Maintain correct shielding and grounding practices to reduce electromagnetic interference. Connect RS-232C interfaces according to the assigned port function. COM3 supports standard serial communication with RTS-CTS signals, while COM4 provides isolated connection for configuration tools. Before commissioning, verify the 24 VDC power supply polarity, grounding connection, backup battery condition, and communication link status through the controller diagnostic indicators. Ensure installation conditions remain within the specified environmental limits, including temperature, humidity, vibration, and pollution degree requirements defined by IEC/EN 61131-2.
$199.00 $99.00
-
ABB PM810V2 3BSE009895R2 ABB Advant OCS Processor Module
ABB PM810V2 Processor Module The ABB 3BSE009895R2 PM810V2, also cataloged as the PM810V2 Processor Module, provides dedicated execution of control logic, system communication handling, and data processing functions within ABB Advant OCS and Industrial IT controller platforms. Hardware Specifications Parameter Specification Model PM810V2 Processor Module Brand ABB Product ID 3BSE009895R2 Series Advant OCS / Industrial IT Product Type Processor Module Origin Sweden Weight Approx. 0.5 kg Dimensions Approx. 7.6 cm x 17.8 cm x 10.2 cm Operating Temp Industrial operating environment (specific range not provided) Power Consumption Not specified in available documentation Mounting Type Standard ABB controller module mounting Application Industrial automation and process control systems Backplane Bus Communication and Controller Integration The ABB PM810V2 operates as a controller processing unit within the Advant OCS architecture. It executes application programs, manages internal data exchange, and communicates with connected controller components through the system backplane. The module supports ABB controller platform integration through dedicated hardware interfaces. Therefore, system configuration depends on the installed controller rack, communication modules, and firmware compatibility requirements. The PM810V2 belongs to ABB industrial control hardware designed for PLC/DCS environments, where backplane communication velocity, I/O density scaling, and firmware flash compatibility influence system performance and lifecycle management. Frequently Asked Questions Q: What is the primary function of the ABB PM810V2 module?A: The PM810V2 functions as a processor module that executes control applications, manages internal processing tasks, and coordinates communication between controller components. Q: Does the PM810V2 support direct I/O connection?A: The module operates as a controller processing unit. Field I/O connections require compatible ABB I/O modules and interface components within the controller architecture. Q: Can the PM810V2 be replaced without system configuration changes?A: Replacement requires verification of controller configuration, firmware compatibility, and hardware addressing settings before installation. Field Installation Guidelines Install the PM810V2 in the designated ABB controller rack position according to system hardware documentation. Verify that the mounting connector and backplane contacts are clean before module insertion. Disconnect system power before removing or installing the processor module. Use appropriate grounding practices for controller cabinets and communication wiring. Keep signal cables separated from high-voltage power cables to reduce electrical interference. Confirm firmware compatibility and controller configuration parameters after module replacement. Check diagnostic indicators after startup to verify processor initialization status.
$199.00 $99.00
-
ABB PM862K01 3BSE076940R1 ABB AC 800M Processor Unit
ABB PM862K01 AC 800M Processor Unit The ABB 3BSE076940R1 (PM862K01), also cataloged as the PM862K01 Processor Unit, operates as a dedicated controller hardware component for application execution, I/O communication, and control task processing within ABB AC 800M automation platforms. Hardware Specifications Parameter Specification Model PM862K01 Article Number 3BSE076940R1 Brand ABB Product Type AC 800M Processor Unit Origin Sweden Weight 1200 g including base Dimensions Width 119 mm, Height 186 mm, Depth 135 mm Operating Temp 0 to +55 deg C Power Consumption 5.1 W typical, 8.6 W maximum Redundancy No High Integrity No Processor Type MPC866 Clock Frequency 67 MHz Performance 0.18 ms per 1000 boolean operations Memory 32 MB RAM Available for Application 23.521 MB Firmware Storage 4 MB Flash PROM Flash Memory for Storage Yes Power Supply 24 V DC (19.2-30 V DC) Power Supply Current 210 mA typical, 360 mA maximum at +24 V Backup Battery Lithium battery, 3.6 V Redundant Power Supply Status Input Yes Ethernet Channels 2 Ethernet Interface IEEE 802.3 Ethernet, 10 Mbit/s, RJ-45 female Control Network Protocol MMS and IAC Recommended Network Backbone 100 Mbit/s switched Ethernet RS-232C Interfaces 2 COM3 Interface RS-232C, 75-19 200 baud, RJ-45 female, RTS-CTS support COM4 Interface RS-232C, 9600 baud, RJ-45 female, opto isolated CEX Bus Communication Modules 12 Maximum CEX Bus Supply Current 2.4 A Modulebus I/O Capacity Maximum 96 I/O modules with single PM862 Modulebus Scan Rate 0-100 ms depending on I/O configuration Clock Synchronization 1 ms between AC 800M controllers by CNCP protocol Event Queue Capacity Up to 3000 events per OPC client Applications per Controller 32 Programs per Application 64 Diagrams per Application 128 Tasks per Controller 32 Different Cycle Times 32 Minimum Application Cycle Time Down to 1 ms ABB AC 800M Controller Communication and I/O Architecture The PM862K01 uses the AC 800M controller architecture to execute application programs and exchange process data through Ethernet and Modulebus interfaces. The processor communicates with control networks through MMS and IAC protocols while supporting distributed I/O configurations. The controller supports up to 12 CEX bus communication modules. Additionally, the Modulebus interface manages electrical and optical I/O clusters according to the installed CPU configuration. A single PM862K01 supports up to 96 I/O modules, while redundant PM862 configurations support up to 84 I/O modules. The firmware storage uses Flash PROM technology, which provides compatibility with AC 800M controller software environments. The internal real-time clock maintains synchronization performance with approximately 100 ppm stability. Firmware Flash Compatibility and Industrial Control Processing The PM862K01 incorporates firmware flash storage and MPC866 processor technology for AC 800M automation control tasks. The processor executes cyclic application programs with configurable task scheduling and supports deterministic communication through Ethernet and Modulebus interfaces. The controller architecture supports firmware-based configuration management, application storage, and controller diagnostics. Furthermore, the backplane and communication structure provide controlled data exchange between processor functions, communication modules, and connected I/O systems. Frequently Asked Questions Q: Does the PM862K01 support redundant CPU operation?A: The PM862K01 hardware is specified as non-redundant. Redundant configurations require compatible redundant controller arrangements and supported AC 800M system components. Q: What communication interfaces are integrated into the PM862K01?A: The controller includes two Ethernet channels and two RS-232C interfaces. Ethernet uses IEEE 802.3 communication with RJ-45 connections. Q: What is the maximum I/O capacity of a single PM862K01 controller?A: A single PM862K01 supports up to 96 I/O modules through the Modulebus interface, depending on system configuration. Field Installation Guidelines Install the PM862K01 on the designated AC 800M controller base plate and verify correct mechanical locking before applying power. Use shielded communication cables for Ethernet and serial connections where required by the installation environment. Maintain separation between signal wiring and high-current power conductors to reduce electromagnetic interference. Verify the 24 V DC supply polarity before connection. Confirm grounding and protective bonding according to industrial control cabinet standards. Before commissioning, check controller firmware compatibility, application configuration, communication module addressing, and connected I/O module status through the engineering environment.
$199.00 $99.00
-
ABB PM856AK01 3BSE069514R1 ABB AC 800M CPU Processors
ABB PM856AK01 Processor Unit The ABB PM856AK01 3BSE069514R1, also cataloged as the PM856AK01 Processor Unit, operates as a dedicated hardware component for control execution, communication management, and diagnostic processing within ABB AC 800M System 800xA controller platforms. Hardware Specifications Parameter Specification Model PM856AK01 3BSE069514R1 Brand ABB Product Type CPU Processor Module System Platform AC 800M Controller / System 800xA Origin Sweden Operating Temp 0 deg C to +55 deg C Power Consumption 4.32 W typical, 7.2 W maximum Supply Voltage +24 VDC Current Consumption 180 mA typical, 300 mA maximum RAM Memory 16 MB application memory Flash Memory 10.337 MB storage memory Communication Interface RS-232C COM port, RJ-45 female 8-pole, opto-isolated Rated Isolation Voltage 500 VAC Controller Family ABB AC 800M Industrial Control Processing and Communication Functions The PM856AK01 processor unit manages application execution, controller diagnostics, and communication services through the AC 800M controller architecture. The module uses firmware flash compatibility functions for application storage and system management. Furthermore, the processor supports AC 800M backplane bus communication velocity functions, allowing coordinated data exchange between controller modules and connected I/O components. The unit provides processing resources for control logic execution, event handling, and network communication tasks. Frequently Asked Questions Q: Does the PM856AK01 support redundant controller configurations?A: The PM856AK01 supports AC 800M controller configurations where redundancy functions depend on the complete controller hardware arrangement and installed communication modules. Q: What power input does the PM856AK01 require?A: The processor unit requires a +24 VDC supply input and consumes 180 mA typical current with a maximum current consumption of 300 mA. Q: Can the PM856AK01 communicate directly with field I/O modules?A: The processor communicates through the AC 800M controller architecture. Field communication depends on the installed communication interfaces and connected I/O modules. Field Installation Guidelines Install the PM856AK01 module on the designated AC 800M controller baseplate according to ABB hardware configuration requirements. Verify the +24 VDC supply polarity before energizing the controller system. Maintain proper cabinet grounding and separate signal wiring from high-voltage power cables to reduce electrical interference. Use approved communication cables for the RS-232C interface and ensure connector locking mechanisms remain secured during operation. Check module status indicators after installation and confirm correct firmware compatibility before loading controller applications.
$199.00 $99.00
-
ABB ABB AC 800M PM863K02 3BSE088382R1 CPU Processors
ABB PM863K02 High Integrity CPU Processor Unit The ABB PM863K02 3BSE088382R1, also cataloged as the PM863K02 High Integrity CPU Processor Unit, provides execution and communication control for AC 800M High Integrity controller platforms. The module manages CPU processing, RAM memory, real-time clock functions, Ethernet communication, serial interfaces, and redundant controller operation. Hardware Specifications Parameter Specification Model PM863K02 3BSE088382R1 Brand ABB Product Type High Integrity CPU Processor Unit Origin Sweden Weight 2700 g including base Dimensions Width 119 mm, Height 186 mm, Depth 135 mm Operating Temp 0 to +55 deg C Power Consumption 5.1 W typical, 8.6 W maximum Processor Type MPC866 Clock Frequency 96 MHz Memory 32 MB RAM Available for Application 22.184 MB Redundancy Supported High Integrity Function Supported with SM812 module and SIL-certified software Performance 0.17 ms per 1000 boolean operations Firmware Storage 18 MB Flash PROM Flash Memory for Storage No Power Supply 24 VDC, 19.2 to 30 VDC Power Consumption Current 210 mA typical, 360 mA maximum at +24 VDC Backup Battery Lithium battery, 3.6 V Ethernet Channels 2 Ethernet Interface IEEE 802.3 Ethernet, 10 Mbit/s, RJ45 female Control Network Protocol MMS and IAC Recommended Network Backbone 100 Mbit/s switched Ethernet RS-232C Interfaces 2 ports COM3 Interface RS-232C, 75 to 19200 baud, modem control, RTS-CTS support COM4 Interface RS-232C, 9600 baud, isolated service tool connection CEX Bus Communication Modules Maximum 12 CEX Bus Supply Current Maximum 2.4 A ModuleBus I/O Capacity Maximum 96 I/O modules single CPU, 84 I/O modules redundant CPU ModuleBus Scan Rate 0 to 100 ms depending on I/O quantity Event Queue Up to 3000 events per OPC client Clock Synchronization 1 ms between AC 800M controllers using CNCP protocol Protection Class IP20 according to EN 60529 Relative Humidity 5 to 95 %, non-condensing Storage Temperature -40 to +70 deg C Isolation Voltage 500 VAC CE Mark Yes Safety Certifications IEC 61508, TÜV, UL 61010-1, UL 61010-2-201 Hazardous Location Certification cULus Class 1 Zone 2, AEx nA IIC T4, Ex nA IIC T4Gc X ABB AC 800M High Integrity Controller Architecture The PM863K02 uses the AC 800M controller architecture with redundant CPU, CEX-Bus, communication interfaces, and S800 I/O support. The controller integrates two Ethernet ports for Control Network communication and provides two serial interfaces for engineering and service functions. The High Integrity configuration requires an SM812 Safety Module and SIL-certified software. Therefore, the controller can execute safety-related applications according to IEC 61508 requirements when configured according to the applicable Safety Manual. The CPU board includes the microprocessor, RAM memory, real-time clock, LED status indicators, INIT push button, and CompactFlash interface. However, the PM863K02 does not provide Flash memory for application storage. Backplane Bus Communication and I/O Density Scaling The PM863K02 supports industrial controller communication through CEX-Bus and ModuleBus interfaces. The controller provides deterministic data exchange between CPU resources, communication modules, and S800 I/O modules. The module supports up to 12 communication modules on the CEX-Bus and provides ModuleBus expansion for electrical and optical I/O clusters. In redundant CPU configurations, the controller maintains coordinated operation between processor units and connected I/O resources. The Ethernet interface operates according to IEEE 802.3 standards and supports MMS and IAC protocols for AC 800M Control Network communication. Frequently Asked Questions Q: Does the PM863K02 support CPU redundancy operation?A: Yes. The PM863K02 supports redundant CPU configurations including CPU synchronization, CEX-Bus redundancy, communication interface redundancy, and S800 I/O redundancy. Q: What additional hardware enables High Integrity functionality?A: High Integrity operation requires an SM812 module together with SIL-certified software. Configuration must follow the AC 800M Safety Manual requirements. Q: What are the available serial communication interfaces?A: The controller provides two RJ45 serial ports. COM3 is a non-isolated RS-232C interface with modem control signals, while COM4 is an isolated RS-232C service tool interface. Field Installation Guidelines Install the PM863K02 on the designated AC 800M controller base plate with correct mechanical alignment. Connect CN1 and CN2 Ethernet ports according to the Control Network topology requirements. Maintain proper separation between Ethernet cables, serial cables, and high-voltage wiring to reduce electrical interference. Connect shielded communication cables using approved grounding practices for industrial control systems. Verify the 24 VDC supply polarity before energizing the controller. Confirm redundant power supply status inputs and battery installation before system commissioning. Configure the SM812 safety module and safety software according to the applicable Safety Manual before enabling High Integrity functions.
$199.00 $99.00
-
ABB ABB Advant Master PM511V08 3BSE011180R1 Processor Module
ABB PM511V08 3BSE011180R1 Processor Module The ABB PM511V08 3BSE011180R1, also cataloged as the PM511V08 Processor Module, executes controller processing tasks and manages application data exchange within ABB Advant Master and ABB Advant OCS control platforms. Hardware Specifications Parameter Specification Model PM511V08 3BSE011180R1 Brand ABB Product Type Processor Module System Platform ABB Advant Master / ABB Advant OCS Origin Sweden Weight 0.75 kg Dimensions 3 x 33.3 x 29.7 cm (shipping size) Operating Temp -25 deg C to +60 deg C Humidity 5-95% non-condensing CPU PowerPC-based processor RAM 128 MB Flash Memory 64 MB Application Memory 8 MB Cycle Time <= 0.1 ms ABB Advant Master Processor Execution and Firmware Flash Compatibility The PM511V08 processor module uses a PowerPC-based CPU architecture to execute control applications, communication services, and system management functions. In addition, the module provides 8 MB application memory with 64 MB flash storage for firmware and system data retention. Furthermore, the processor module supports ABB control system backplane communication, where deterministic data transfer maintains synchronized operation between controller components and connected I/O resources. The firmware flash compatibility allows the module to store operating software and configuration information required by the Advant Master platform. The module design follows ABB industrial controller architecture principles, including controlled processing cycle execution and memory resource allocation for distributed automation applications. Frequently Asked Questions Q: What controller platform is the PM511V08 3BSE011180R1 designed for?A: The PM511V08 processor module is designed for ABB Advant Master and ABB Advant OCS control system platforms. Q: What memory resources are available on the PM511V08 module?A: The module provides 128 MB RAM, 64 MB flash memory, and 8 MB application memory capacity. Q: Can the PM511V08 operate in redundant controller configurations?A: The supplied technical data does not specify redundancy switching parameters. Configuration capability depends on the installed ABB controller architecture and system software. Field Installation Guidelines Install the PM511V08 module only in the designated ABB controller rack position according to the system hardware configuration documentation. Before installation, verify that the rack power supply is disconnected and that the module connector area remains clean and free from contamination. Ensure correct alignment with the backplane connector before insertion. Maintain proper cabinet ventilation to keep the operating temperature within the specified range. Route communication and power wiring separately where applicable to reduce electrical interference. During maintenance activities, confirm firmware compatibility and controller configuration settings before replacing or upgrading the processor module.
$199.00 $99.00
-
ABB TB811 ABB S800 I/O Optical ModuleBus Ports
ABB TB811 3BSE008568R1 Optical ModuleBus Port Configured for optical ModuleBus communication in ABB S800 I/O systems, the ABB TB811 3BSE008568R1 (TB811 Optical ModuleBus Port) provides direct physical interface conversion between electrical ModuleBus signals and optical communication links. Hardware Specifications Parameter Specification Model TB811 3BSE008568R1 Brand ABB Product Type Optical ModuleBus Port Origin Sweden Dimensions 2 x 5.2 x 4.2 cm Operating Temp -40 deg C to +70 deg C Storage Temp -40 deg C to +85 deg C Power Consumption <= 2 W Supply Voltage 24 V DC (18 - 30 V) Current Draw <= 85 mA @ 24 V Electrical Interface RS-485 half-duplex Optical Budget 12 dB Isolation 2.5 kV AC Humidity 5 - 95 % RH, non-condensing Application Interface ABB ModuleBus optical communication Compatible Equipment CI810 / CI820 communication interfaces, ABB drives equipment Tariff Code 8537101190 ABB Industrial Communication Interface Characteristics The TB811 3BSE008568R1 uses ABB ModuleBus optical communication technology to extend communication distance and maintain signal isolation between connected system components. The unit converts RS-485 half-duplex electrical communication into an optical ModuleBus connection for ABB control architectures. Furthermore, the module supports ABB backplane bus communication velocity and I/O density scaling requirements within S800 I/O configurations. The 2.5 kV AC isolation separates electrical circuits and reduces the influence of potential differences between connected devices. The optical interface provides a 12 dB optical budget, allowing installation flexibility in distributed I/O configurations. The module operates from a 24 V DC supply and maintains low current consumption for control cabinet integration. Frequently Asked Questions Q: What communication interface does the ABB TB811 3BSE008568R1 support?A: The TB811 supports RS-485 half-duplex electrical communication and provides an optical ModuleBus port interface. Q: Can the TB811 be used with ABB CI810 and CI820 interfaces?A: Yes. The TB811 is designed for use with ABB CI810 and CI820 communication interfaces and related ModuleBus configurations. Q: What power supply range does the TB811 require?A: The module requires a 24 V DC supply with an operating voltage range of 18 - 30 V DC. Field Installation Guidelines Install the TB811 on a suitable DIN rail or approved ABB mounting arrangement according to the control cabinet design requirements. Verify the 24 V DC supply polarity before energizing the module. Maintain separation between communication wiring and high-current power cables to reduce electromagnetic interference. Connect optical fibers with correct alignment and protect fiber connectors from contamination during installation. Inspect optical interfaces before connection to avoid signal attenuation caused by dust or mechanical damage. Confirm RS-485 wiring polarity and grounding practices according to ABB installation documentation. Use appropriate shielding methods when installing the module in environments with electrical noise sources.
$199.00 $99.00
-
ABB AO845A 3BSE045584R1 ABB S800 I/O Analog Output Modules
ABB AO845 3BSE045584R1 Analog Output Module The ABB AO845 3BSE045584R1 serves as the primary AO845 Analog Output Module utilized to execute 4-20 mA signal output control across ABB S800 I/O system platforms. The module provides 8 unipolar analog output channels with HART communication support and supports single or redundant configuration through ModuleBus. Hardware Specifications Parameter Specification Model AO845 3BSE045584R1 Brand ABB Origin Sweden Weight 0.21 kg Dimensions 45 mm W x 102 mm D x 119 mm H Operating Temp 0 to +55 deg C Power Consumption Typ. 3.5 W Product Type Analog Output Module Series ABB S800 I/O Signal Specification 4-20 mA Number of Channels 8 unipolar analog output channels HART Support Yes Redundancy Support Yes Resolution 12 bit Isolation Groupwise isolated from ground Output Load Maximum 750 ohm Output Error Maximum 0.1% Temperature Drift Maximum 50 ppm/deg C Update Cycle Time 10 ms Current Limiting Short circuit proof current limited output Maximum Field Cable Length 600 m Rated Insulation Voltage 50 V Dielectric Test Voltage 500 V AC Current Consumption +5 V ModuleBus Maximum 125 mA Current Consumption +24 V External 218 mA MTU Compatibility TU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852 Keying Code DB Protection Class IP20 according to IEC 60529 EMC Standard EN 61000-6-4 and EN 61000-6-2 Safety Standard EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 ABB S800 I/O Backplane Communication and I/O Density Scaling The AO845 module operates within the ABB S800 I/O architecture and exchanges process data through the ModuleBus interface. The hardware supports I/O density scaling by providing eight analog output channels in a compact S800 module format. Additionally, redundant operation allows two modules to participate in a coordinated configuration where the ModuleBus master manages module status supervision. The module performs cyclic self-diagnostics during operation. External channel errors are generated when process power supply conditions are insufficient or when the measured output current does not match the configured value above the 1 mA threshold. Internal channel errors are reported when the output circuit cannot maintain the requested current value. Module-level diagnostics monitor output transistor faults, short circuits, checksum failures, internal power supply conditions, status link errors, watchdog operation, and incorrect OSP behavior. Therefore, the system can identify hardware execution faults through the module diagnostic interface. Frequently Asked Questions Q: Does the AO845 3BSE045584R1 support redundant operation?A: Yes. The AO845 supports redundant applications. In redundant configurations, the ModuleBus master supervises module status and commands the module to an error state when internal faults occur. Q: What type of field signals can the AO845 output?A: The module provides eight unipolar analog output channels with 4-20 mA signal capability and HART communication support. Q: How does the module handle output short circuits?A: The AO845 uses current-limited output circuitry with short circuit protection. Diagnostic functions report output transistor errors and channel faults. Field Installation Guidelines Install the AO845 module on compatible ABB S800 I/O MTUs according to the selected hardware configuration. Verify the MTU keying code before mounting the module to prevent incorrect module placement. Connect field wiring according to the approved terminal assignment. Maintain proper cable routing between analog signal wiring and high-energy conductors to reduce electromagnetic interference. Use appropriate shield grounding practices according to the installation standard of the control system. Before commissioning, verify the external process power supply, channel configuration, ModuleBus communication status, and diagnostic LED indications. Confirm that the connected field devices match the configured 4-20 mA output range.
$199.00 $99.00
-
ABB DO840 3BSE020838R1 ABB S800 I/O Digital Output Modules
ABB DO830 3BSE020838R1 Digital Output Module The ABB DO830 3BSE020838R1, also cataloged as the DO830 Digital Output Module, provides direct electrical execution of current sourcing output signals within the ABB S800 I/O system. It contains 16 digital output channels with 24 VDC signal operation, current limitation, over temperature protection, and groupwise isolation. Hardware Specifications Parameter Specification Model DO830 3BSE020838R1 Brand ABB Product Type Digital Output Module Series S800 I/O Origin Sweden Weight 0.15 kg Dimensions Width 45 mm, Depth 102 mm, Height 119 mm Operating Temp 0 to +55 deg C Power Consumption Typ. 4.3 W Signal Specification 24 VDC (19.2 to 32 VDC), 0.5 A Number of Channels 16 digital output channels Signal Type Current sourcing, current limiting Output Current Maximum 0.5 A per channel continuous HART Support No SOE Support No Redundancy Yes High Integrity No Intrinsic Safety No Isolation Groupwise isolated from ground Current Protection Short circuit proof current limited output Field Cable Length Maximum 600 m Rated Insulation Voltage 50 V Dielectric Test Voltage 500 VAC ModuleBus Current Consumption +5 V 130 mA ModuleBus Current Consumption +24 V 0 mA External +24 V Current Consumption 200 mA Compatible MTU TU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852 Keying Code CE Protection Class IP20 according to IEC 60529 EMC Compliance EN 61000-6-4, EN 61000-6-2 Electrical Safety EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 Hazardous Location Approval C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2 Marine Certification DNV Storage Temperature -40 to +70 deg C Humidity 5 to 95 %, non-condensing Pollution Degree Degree 2, IEC 60664-1 Corrosion Protection ISA-S71.04 G3 RoHS Compliance EU RoHS, UAE RoHS, CN RoHS WEEE Compliance Directive 2012/19/EU ABB S800 I/O Backplane and I/O Density Scaling The DO830 operates as an ABB S800 I/O digital output component with direct ModuleBus communication to the control system. The module integrates 16 output channels in a compact S800 mechanics design and supports redundant configurations through compatible termination units. Each output channel uses a high side driver with current limitation, over temperature protection, EMC protection components, inductive load suppression, status indication LED, and optical isolation. Therefore, the module maintains electrical separation between field circuits and internal electronics. The output architecture supports I/O density scaling within ABB automation systems while maintaining channel-level diagnostics. In addition, the module provides process voltage supervision through two groups, with each group containing eight output channels and one supervision input. Frequently Asked Questions Q: Does the DO830 support HART or Sequence of Events (SOE) functions?A: No. The DO830 is a digital output module without HART communication or SOE event recording capability. Q: How are the output channels protected against field faults?A: Each output channel includes current limitation and over temperature protection. The output design provides short circuit proof operation. Q: Which MTUs are compatible with the DO830 module?A: The DO830 supports TU810, TU812, TU814, TU830, TU833, TU842, TU843, and TU852 termination units. Field Installation Guidelines Install the DO830 module according to ABB S800 I/O mechanical and electrical installation requirements. Connect field wiring through the specified compatible MTU and verify correct keying before module insertion. Maintain proper separation between signal wiring and high voltage power cables to reduce EMC interference. Verify external 24 VDC field supply polarity before energizing the outputs. The protective earth and cabinet grounding system must follow site electrical standards. Use shielded cables where required by the installation environment. Connect cable shields according to the control cabinet grounding design to minimize electrical noise coupling. Check front LED indicators after startup. Confirm module status, warning indication, and individual channel status before placing the output channels into operational service.
$199.00 $99.00
-
ABB TB840 3BSE021456R1 ABB Communication Modules
ABB TB840 Modulebus Cluster Modem Configured for optical cluster modem operation in the ABB Modulebus network, the ABB 3BSE021456R1 (TB840 Modulebus Cluster Modem) provides optical communication for 1+1 redundant operation. The hardware supports the specified TB840 functionality and uses a pin-compatible successor, TB840A, where hardware changes do not alter the stated functionality. Hardware Specifications Parameter Specification Model TB840 Full Product ID 3BSE021456R1 Brand ABB Product Type Communication Module Function Modulebus Cluster Modem Communication Interface Optical Redundancy 1+1 redundant operation Compatibility Pin-compatible with TB840A Product Status Replaced by TB840A Weight 0.272 kg Dimensions 16 cm D x 15.7 cm H x 8 cm W Optical Modulebus Communication and Redundancy TB840 operates as an optical cluster modem within the Modulebus architecture. It supports 1+1 redundant operation, allowing the hardware arrangement to maintain the specified cluster communication function across a redundant configuration. The supplied ABB data identifies TB840A as the pin-compatible replacement. ABB states that hardware changes were implemented without changing the functionality specified for TB840. Therefore, installation and replacement work should verify the exact hardware revision and system compatibility before commissioning. The optical communication path should also remain physically protected from excessive bending, contamination, and mechanical stress. Frequently Asked Questions Q: What is the primary function of ABB TB840 3BSE021456R1?A: TB840 is an optical Modulebus Cluster Modem designed for 1+1 redundant operation. Q: Can TB840 be replaced by TB840A?A: ABB identifies TB840A as the pin-compatible replacement and states that hardware changes did not change the specified functionality. Q: What operating temperature and power consumption does TB840 support?A: The supplied product data does not specify operating temperature or power consumption. These values should therefore be taken from the applicable ABB hardware documentation for the installation revision. Field Installation Guidelines Verify the complete product identification as 3BSE021456R1 before installation. Confirm the Modulebus architecture and required 1+1 redundant configuration before connecting the modem. Inspect optical connectors and interfaces for contamination or mechanical damage before connection. Route optical communication cables separately from high-energy power wiring where practical. Avoid excessive cable bending, tensile loading, or repeated mechanical movement at optical connections. Confirm connector engagement and mechanical retention before energizing the system. Check module seating and physical mounting before applying system power. When replacing TB840 with TB840A, verify pin compatibility and the applicable ABB hardware revision. Do not apply undocumented voltage or signal connections to the communication interface. Complete communication and redundancy checks after installation before returning the Modulebus network to service.
$199.00 $99.00
-
ABB DI885 3BSE013088R1 ABB Advant S800 I/O Digital Input Modules
ABB DI885 3BSE013088R1 Digital Input Module Configured for 24/48 VDC sequence-of-events input acquisition, the ABB 3BSE013088R1 (DI885 Digital Input Module) provides eight digital input channels with a rated isolation of 50 V. The module supports SOE processing and connects through compatible ABB S800 I/O Module Termination Units. Hardware Specifications Parameter Specification Model DI885 3BSE013088R1 Brand ABB Product Type Digital Input Module Product Type Designation I-O_Module Catalog Description Digital Input 24/48 V SOE 8 ch Input Type Digital Input (DI) Number of Input Channels 8 Input Voltage 24/48 VDC SOE Function Supported Channel Configuration 1 x 8 channels Rated Isolation 50 V Compatible MTUs TU810, TU812, TU814, TU830 Dimensions 102 mm D x 119 mm H x 45 mm W Weight 0.3 kg Origin Sweden WEEE Category 5 - Small Equipment ABB Industrial I/O and SOE Characteristics The DI885 accepts 24 VDC or 48 VDC digital input signals across eight channels. It processes the channels as an SOE input module, allowing the connected control system to acquire event-oriented digital status information. The module provides a 50 V rated isolation level. Therefore, field wiring must remain within the specified electrical isolation conditions of the module and associated termination unit. For installation, the DI885 supports the TU810, TU812, TU814, and TU830 Module Termination Units. The selected MTU must match the physical and electrical configuration of the S800 I/O installation. Because the supplied documentation identifies this unit as a spare part for systems placed on the market before July 22, 2017, application engineers should verify system compatibility before replacement. The supplied data also states that the unit is not RoHS 2 2011/65/EU compliant. Frequently Asked Questions Q: How many digital input channels does the DI885 provide?A: The DI885 provides 8 digital input channels configured as 1 x 8 channels. Q: What input voltage does the DI885 support?A: The module is specified for 24/48 VDC digital input signals. Q: Which Module Termination Units are compatible with the DI885?A: The supplied ABB data specifies TU810, TU812, TU814, and TU830 as compatible Module Termination Units. Field Installation Guidelines Install the DI885 on the specified ABB S800 I/O assembly and use a compatible Module Termination Unit. Verify the field signal voltage before connecting the eight digital input channels. Keep field wiring within the module's specified 50 V rated isolation conditions. Route digital input wiring separately from high-current power conductors where practical to reduce electrical interference. Maintain correct channel identification during termination to prevent signal assignment errors. Inspect terminal connections for secure mechanical contact before energizing the I/O assembly. Confirm the installed MTU type against the system documentation before commissioning. For replacement applications, verify hardware compatibility with the existing S800 I/O configuration and system revision. Follow the applicable plant grounding and shield termination practices for the installed control cabinet.
$199.00 $99.00
-
ABB TY801K01 3BSE023607R1 ABB Advant S800 I/O Shunt Stick Kit
ABB TY801K01 3BSE023607R1 Shunt Stick Kit Configured for shunt resistance selection in S800 I/O termination assemblies, the ABB TY801K01 3BSE023607R1 (TY801K01 shunt stick kit) provides eight TY801 shunt sticks for AI845 and AI880A applications on compatible TU834, TU844, TU845, and TU854 termination units. Each shunt stick uses a 125 + 125 ohm shunt arrangement. Hardware Specifications Parameter Specification Model TY801K01 3BSE023607R1 Spare Model 3BSE023607R1 Brand ABB Product Type Shunt Stick Kit Quantity 8 pcs TY801 Shunt Sticks Shunt Resistance 125 + 125 ohms Compatible I/O Modules AI845, AI880A Compatible MTUs TU834, TU844, TU845, TU854 ModuleBus Ports 2 x redundant I/O Slots 8 x S800 I/O module Power Consumption 2 W typical Operating Temp -20 deg C to +70 deg C Storage Temp -40 deg C to +85 deg C Humidity 5 - 95 % RH, non-condensing Weight 0.06 kg Dimensions 11 x 10 x 1.5 cm estimated shipping size Origin Sweden Tariff Code 8537101190 Manufacturer ABB ABB S800 I/O Shunt Configuration The TY801K01 provides eight individual TY801 shunt sticks for defined signal termination arrangements. Each stick incorporates a 125 + 125 ohm shunt configuration. The shunt sticks support AI845 and AI880A installations when used with the specified TU834, TU844, TU845, and TU854 module termination units. Therefore, technicians should verify the I/O module and MTU combination before installation. The supplied quantity matches an eight-channel termination arrangement. However, the TY801K01 itself functions as a passive shunt accessory rather than an independent I/O processing module. Frequently Asked Questions Q: What does the TY801K01 package contain?A: The package contains 8 pcs TY801 shunt sticks. Q: What shunt resistance does each TY801 provide?A: Each TY801 uses a 125 + 125 ohm shunt arrangement. Q: Which ABB I/O modules are specified for TY801 use?A: The supplied data specifies AI845 and AI880A, installed with TU834, TU844, TU845, or TU854 MTUs. Field Installation Guidelines Confirm the installed S800 I/O module and MTU model before fitting the shunt sticks. Isolate the relevant field circuit before modifying the termination assembly. Install each TY801 shunt stick in the designated termination position specified by the applicable ABB hardware documentation. Verify that the shunt stick is fully seated and that no contact pins are displaced. Keep signal wiring separated from high-current switching conductors where practical. Inspect terminal connections for correct seating and mechanical retention before energizing the circuit. After installation, verify the configured signal path and resistance arrangement against the approved control-system drawings. Do not substitute a different resistance value unless the system design explicitly specifies that configuration.
$199.00 $99.00
-
ABB DI830 3BSE013210R1 ABB Advant S800 I/O Digital Input SOE Module
ABB DI830 3BSE013210R1 Digital Input SOE Module Configured for time-stamped digital event acquisition, the ABB DI830 3BSE013210R1 (DI830 Digital Input SOE Module) accepts 16 current-sinking inputs at 24 VDC. It records input events with 0.4 ms resolution and provides an event recording accuracy of -0.3 ms to +0.7 ms. Hardware Specifications Parameter Specification Model DI830 3BSE013210R1 Brand ABB Product Type Digital Input SOE Module Origin Sweden Weight 0.2 kg Signal Specification 24 VDC Number of Channels 16 Signal Type Current sinking Input Voltage Range -30 to +5 V Input Voltage Range 13 to 30 V Input Impedance 3.2 kOhm Filter Times 0 to 100 ms Maximum Field Cable Length 600 m Event Recording Accuracy -0.3 ms to +0.7 ms Event Recording Resolution 0.4 ms Rated Insulation Voltage 50 V Dielectric Test Voltage 500 VAC ABB I/O Density and SOE Characteristics The DI830 provides 16 digital input channels within one module. Therefore, the module supports high channel density for discrete event acquisition while maintaining individual input signal processing. The current-sinking input design accepts field signals within the specified voltage ranges. Furthermore, the 3.2 kOhm input impedance defines the electrical load presented to the connected field circuit. The configurable filter time ranges from 0 to 100 ms. Consequently, the input processing can accommodate different requirements for signal filtering and transient suppression. For sequence-of-events applications, the module records events with 0.4 ms resolution. The specified recording accuracy is -0.3 ms to +0.7 ms, providing the timing characteristics stated for event capture. Frequently Asked Questions (FAQ) Q: How many digital input channels does the DI830 provide?A: The DI830 provides 16 digital input channels. Q: What input signal type does the DI830 use?A: The module uses current-sinking digital inputs with a nominal 24 VDC signal specification. Q: What are the SOE timing specifications?A: The event recording resolution is 0.4 ms, while event recording accuracy is specified as -0.3 ms to +0.7 ms. Field Installation Guidelines Verify the module identification as DI830 3BSE013210R1 before installation. Confirm that field signal voltage remains within the specified input voltage ranges. Connect field wiring according to the applicable ABB system wiring documentation. Keep digital input wiring separated from high-voltage power and high-current switching conductors where practical. Route signal cables to minimize exposure to electromagnetic interference from motors, contactors, and switching equipment. Maintain appropriate shielding and grounding practices according to the control system installation standard. Check cable length before commissioning; the specified maximum field cable length is 600 m. Verify input polarity and current-sinking circuit configuration before applying field power. Configure filter times according to the required signal response and noise rejection characteristics. During commissioning, verify individual channel transitions and confirm the expected SOE event timestamps.
$199.00 $99.00
-
ABB 3BSE018126R1 TP853 ABB Advant Module Termination Unit
ABB TP853 Module Termination Unit Configured for physical mounting and electrical interconnection of CI853, CI855, CI857, and CI861 communication interface modules in ABB control systems, the ABB 3BSE018126R1 (TP853 Module Termination Unit) provides the specified baseplate interface for these CI module configurations. Hardware Specifications Parameter Specification Model TP853 Product ID 3BSE018126R1 Brand ABB Product Type Module Termination Unit Application Baseplate for CI853, CI855, CI857, and CI861 Compatible Modules CI853, CI855, CI857, CI861 Origin Sweden / United States Weight 0.5 kg net; 0.5 kg gross Dimensions 162 mm depth x 63 mm height x 45 mm width Operating Temp Not specified in the supplied data Power Consumption Not specified; passive baseplate power consumption is not stated Minimum Order Quantity 1 piece Selling Unit piece Part Type New Frame Size Spare_Parts Customs Tariff Number 85369095 CN8 85389091 WEEE Category 5. Small Equipment WEEE Classification Business To Business Industrial Control Interface Characteristics The TP853 functions as the specified baseplate for selected ABB CI communication interface modules. Therefore, installation establishes the mechanical and electrical mounting interface required by the associated CI module assembly. The supplied technical information identifies four compatible module families: CI853, CI855, CI857, and CI861. In particular, the TP853 forms part of the following configurations: CI853K01, product ID 3BSE018103R1 CI855K01, product ID 3BSE018106R1 CI857K01, product ID 3BSE018144R1 CI861K01, product ID 3BSE058590R1 The TP853 itself is identified as a Module Termination Unit and does not have a separately specified communication protocol, channel count, operating temperature range, or power consumption in the supplied data. Consequently, engineers should obtain those parameters from the corresponding CI module documentation rather than assigning them to the baseplate. Frequently Asked Questions Q: Which ABB communication interface modules are specified for the TP853? A: The supplied ABB data identifies CI853, CI855, CI857, and CI861 as compatible modules. Q: What are the physical dimensions of the TP853? A: The specified product dimensions are 162 mm depth, 63 mm height, and 45 mm width. Q: Does the supplied data specify TP853 power consumption or operating temperature? A: No. The supplied technical information does not provide a numerical power consumption value or operating temperature range. Field Installation Guidelines Verify the TP853 part number, 3BSE018126R1, before installation. Confirm that the selected CI module belongs to the specified CI853, CI855, CI857, or CI861 families. Mount the baseplate according to the applicable ABB system installation documentation. Ensure the mounting surface remains mechanically stable and free from contamination. Install the associated CI module only after confirming correct mechanical alignment with the baseplate. Route field and communication wiring according to the installation requirements of the associated CI module. Keep communication wiring separated from high-current or high-noise conductors where the system installation rules require segregation. Verify terminal and connector engagement before energizing the assembled system. Do not assign operating temperature, current consumption, or communication specifications to the TP853 unless ABB documentation for the specific system configuration provides them.
$199.00 $99.00
-
ABB TU834 3BSE040364R1 ABB Advant S800 I/O Module Termination Units
ABB TU834 Extended Module Termination Unit Configured for direct field wiring and ModuleBus distribution in ABB S800 I/O systems, the ABB TU834 3BSE040364R1 (TU834 Module Termination Unit) provides physical terminal interfaces for up to 8 I/O channels and process voltage connections. Each channel provides two I/O connections and one ZP connection. The MTU also shifts outgoing position signals to generate the correct address for the next I/O module. Hardware Specifications Parameter Specification Model TU834 Article Number 3BSE040364R1 Brand ABB Product Type Extended Module Termination Unit Configuration Single I/O Connection Terminal block Channels 8 Maximum Rated Voltage 50 V Maximum Current per I/O Channel 2 A Maximum Current per Process Connection 5 A Process Connections 40 total I/O Connections Up to 8 I/O channels, 2 terminals per channel Process Power Connections 4 Process Power 0 V Connections 20 ZP Connection 1 per channel Input Signal Connection Individual shunt sticks, TY801 ModuleBus Function Distributes ModuleBus to the next MTU Position Signal Function Shifts outgoing position signals to the next MTU Compatible I/O AI880 and AI880A Mounting Standard DIN rail Mounting Direction Both directions DIN Rail Locking Mechanical latch Weight 0.28 kg (0.6 lb) Dimensions 126 mm W x 64 mm D x 110 mm H including connector, terminals, and locking device as specified Installed Width 120.5 mm edge to edge Operating Temperature 0 to +55 deg C (+32 to +131 deg F) Storage Temperature -40 to +70 deg C (-40 to +158 deg F) Relative Humidity 5 to 95 %, non-condensing Pollution Degree Degree 2, IEC 60664-1 Protection Class IP20 according to IEC 60529 Dielectric Test Voltage 500 V AC Corrosion Protection ISA-S71.04: G3 EMC EN 61000-6-4, EN 61000-6-2 Electrical Safety EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 Hazardous Location C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2 Marine Certifications ABS, BV, DNV-GL, LR Equipment Class Class I according to IEC 61140 RoHS EN 50581:2012 WEEE DIRECTIVE/2012/19/EU ABB S800 I/O Interface and ModuleBus Function The TU834 provides the physical connection between compatible ABB S800 I/O modules and field wiring. Each of its 8 channels has two I/O terminals and one ZP connection, while individual shunt sticks TY801 connect input signals. The MTU also distributes the ModuleBus to the following MTU. At the same time, it shifts the outgoing position signals so that the next I/O module receives its required address position. Therefore, correct MTU sequencing and mechanical installation directly affect I/O module addressing. The TU834 supports DIN-rail installation and uses a mechanical latch to secure the unit to the rail. Installers can mount the unit in either permitted direction according to the system assembly arrangement. For industrial control installations, the specified I/O density allows multiple field channels to terminate through one compact MTU. However, each channel must remain within the stated 50 V maximum voltage and 2 A maximum current limits. Frequently Asked Questions Q: How many I/O channels does the ABB TU834 support? A: The TU834 supports up to 8 I/O channels. Each channel provides two I/O connections and one ZP connection. Q: What is the maximum electrical rating for each I/O channel? A: The maximum rated voltage is 50 V, while the maximum current is 2 A per I/O channel. The maximum current for a process connection is 5 A. Q: How does the TU834 handle ModuleBus and I/O addressing? A: The MTU distributes ModuleBus to the next MTU and shifts outgoing position signals to generate the correct address position for the next I/O module. Field Installation Guidelines Mount the TU834 on a compatible standard DIN rail and engage the mechanical locking latch fully. Verify the mounting direction and maintain the required physical arrangement of adjacent S800 I/O components. Connect field wiring through the designated terminal connections and use TY801 shunt sticks for the specified input signal connections. Keep each I/O channel within the 50 V maximum voltage and 2 A maximum current ratings. Keep process connection loading within the specified 5 A maximum current. Use compatible conductor sizes: 0.2 - 4 mm2 for solid conductors or 0.2 - 2.5 mm2 for stranded conductors. Apply the specified terminal torque of 0.5 - 0.6 Nm and strip approximately 7 mm of insulation. Route signal wiring separately from high-energy power conductors where the installation environment requires noise reduction. Verify terminal identification before energizing the I/O circuit. Inspect the ModuleBus path and adjacent MTU sequence before commissioning to ensure correct position signal propagation and I/O addressing. Confirm the installation environment remains within the specified operating temperature, humidity, pollution, and IP20 conditions. Connect protective earth according to the applicable system installation requirements and the Class I equipment classification.
$199.00 $99.00
-
ABB TU842 3BSE020850R1 ABB Advant S800 I/O Module Termination Unit
ABB TU842 3BSE020850R1 Module Termination Unit Configured for redundant I/O termination in ABB S800 I/O systems, the ABB TU842 3BSE020850R1 (TU842 Module Termination Unit) provides terminal-block connections for up to 16 I/O channels. It supports 50 V operation, horizontal mounting, and separate process-connection current limits. Hardware Specifications Parameter Specification Model TU842 3BSE020850R1 Spare Model 3BSE020850R1 Brand ABB Product Type Module Termination Unit Configuration Redundant Connection Terminal block Channels 16 Voltage 50 V Maximum Current per I/O Channel 3 A Maximum Current Process Connection 10 A Dielectric Test Voltage 500 VAC Mounting Horizontal Mounting Detail 55 deg Operating Temp 0 to +55 deg C; approvals issued for +5 to +55 deg C Storage Temp -40 to +70 deg C Weight 0.6 kg Dimensions Estimated shipping size: 18.5 x 13 x 6 cm Power Consumption Not specified in the supplied data Origin Sweden S800 I/O Termination and Redundancy The TU842 uses a terminal-block connection structure for field-side I/O wiring. Its redundant configuration supports installations where the associated I/O architecture requires redundant termination. The unit provides 16 channels and accepts up to 50 V. Meanwhile, the specified maximum current reaches 3 A per I/O channel and 10 A at the process connection. Therefore, field wiring must remain within both limits. The dielectric test voltage is specified as 500 VAC. Installers should verify the associated I/O module, terminal arrangement, and system configuration before energizing the circuit. Frequently Asked Questions (FAQ) Q: How many I/O channels does the ABB TU842 3BSE020850R1 support?A: The TU842 provides 16 I/O channels through its terminal-block connection arrangement. Q: What are the specified current limits for the TU842?A: The maximum current is 3 A per I/O channel and 10 A for the process connection. Q: Can the TU842 operate across the full specified storage temperature range?A: No. The operating range is 0 to +55 deg C, while the storage range is -40 to +70 deg C. The two ranges apply to different operating conditions. Field Installation Guidelines Mount the TU842 horizontally and secure it according to the mechanical requirements of the associated S800 I/O installation. Verify the terminal-block identification before connecting field conductors. Keep each I/O channel within the specified 3 A maximum current. Keep the process connection within the specified 10 A maximum current. Route field wiring separately from high-voltage or high-noise conductors where the installation requires signal separation. Connect cable shields according to the system grounding design and applicable site electrical standards. Check terminal tightness and conductor seating before applying power. Confirm that the ambient operating temperature remains within 0 to +55 deg C. Do not treat the -40 to +70 deg C storage range as an operating temperature range. Verify the associated redundant I/O configuration before commissioning the termination assembly.
$199.00 $99.00
-
ABB TU844 3BSE02445R1 ABB Advant S800 I/O Module Termination Unit
ABB TU844 Module Termination Unit Configured for module termination and field wiring interface functions in ABB S800 I/O installations, the ABB TU844 3BSE021445R1 (TU844 Module Termination Unit) provides the physical termination point between field wiring and the associated I/O module. The supplied data identifies the unit as a compact module termination component and lists it as discontinued by the manufacturer. Hardware Specifications Parameter Specification Model TU844 Spare Model 3BSE021445R1 Brand ABB Product Type Module Termination Unit Product Description Compact Module Termination Unit Weight 0.58 kg Dimensions Estimated shipping size: 13.5 x 13 x 6.5 cm Manufacturer Status Discontinued by manufacturer ABB S800 I/O Termination Characteristics The TU844 provides a physical termination interface for an ABB S800 I/O assembly. Therefore, installation should maintain correct mechanical seating and field-wiring routing according to the associated ABB I/O hardware documentation. The supplied data does not define channel count, terminal assignments, rated voltage, current capacity, isolation characteristics, or backplane electrical consumption. Consequently, these parameters should not be inferred from the TU844 model designation. For ABB S800 I/O systems, the termination unit forms part of the module-level hardware arrangement. In addition, technicians should verify the compatible I/O module and mounting configuration before replacement or commissioning. Frequently Asked Questions Q: What is the primary function of the ABB TU844? A: The TU844 functions as a Module Termination Unit that provides the physical termination interface for associated ABB S800 I/O hardware. Q: Does the supplied specification define TU844 electrical ratings? A: No. The supplied data does not specify operating voltage, current rating, isolation, power consumption, or terminal electrical limits. Q: Is TU844 a current ABB product? A: The supplied description identifies TU844, spare number 3BSE021445R1, as discontinued by the manufacturer. Field Installation Guidelines Verify the exact TU844 model and spare number before installation. Confirm mechanical compatibility with the associated ABB S800 I/O module and mounting arrangement. Isolate the relevant control-system power before removing or installing field termination hardware. Route field wiring separately from high-voltage and high-noise conductors where practical. Maintain secure terminal connections and prevent excessive mechanical loading on connected conductors. Inspect the termination area for damaged terminals, loose conductors, contamination, or mechanical deformation. Follow the ABB system installation documentation for grounding, shielding, terminal assignments, and module-specific wiring requirements. After installation, verify wiring continuity and correct signal identification before returning the associated I/O circuit to service.
$199.00 $99.00
-
ABB DI803 3BSE022362R1 ABB Advant S800 I/O Digital Input Module
ABB DI803 3BSE022362R1 Digital Input Module The ABB DI803 3BSE022362R1, also cataloged as the DI803 Digital Input Module, provides eight-channel digital input processing for 230 V field signals within ABB industrial control systems. The module accepts discrete electrical states and transfers input status to the control system through its I/O interface. Hardware Specifications Parameter Specification Model DI803 3BSE022362R1 Spare Model 3BSE022362R1 Brand ABB Product Type Digital Input Module Channel Count 8 channels Input Type Digital input Rated Input Voltage 230 V Origin Sweden Weight 0.24 kg Dimensions 9.3 x 13.6 x 5.7 cm shipping size ABB Industrial I/O Architecture The DI803 processes discrete field states through eight digital input channels. Each channel monitors the connected field circuit and reports its electrical state to the control system. Therefore, correct field wiring and terminal identification must match the installed I/O configuration. The 230 V input rating distinguishes this module from low-voltage digital input variants. Consequently, technicians must verify the field circuit voltage before connecting the module. The supplied documentation does not specify channel isolation, input current, switching thresholds, or backplane current consumption, so these parameters require confirmation from the applicable ABB hardware documentation. Frequently Asked Questions Q: How many digital input channels does the ABB DI803 3BSE022362R1 provide?A: The module provides 8 digital input channels. Q: What field voltage does the DI803 support according to the supplied specification?A: The supplied product marking identifies the module as a 230 V digital input device. Q: Does the supplied data specify the DI803 operating temperature and power consumption?A: No. The provided data does not state either parameter, so installation should follow the applicable ABB system documentation. Field Installation Guidelines Verify the module identification as DI803 3BSE022362R1 before installation. Confirm that the connected field circuits match the specified 230 V digital input application. Isolate field power before wiring or removing field connections. Route field wiring separately from high-current power conductors where practical. Maintain clear terminal identification to prevent cross-connection between input channels. Apply the applicable ABB grounding and cabinet bonding practices for the installed I/O system. Inspect conductors and terminal connections for mechanical security before energizing the circuit. After installation, verify each input channel using the actual field switching condition. Do not apply unspecified voltages or signal types to the module. Confirm environmental limits and system-specific installation requirements from the relevant ABB documentation before commissioning.
$199.00 $99.00
-
ABB ABB CI810B 3BSE020520R1 Fieldbus Communication Interface
ABB CI810B 3BSE020520R1 Fieldbus Communication Interface The ABB CI810B 3BSE020520R1, also cataloged as the CI810B Fieldbus Communication Interface, provides AF100 fieldbus communication through two AF100 twisted-pair modems within ABB control system architectures. It operates from a 24 VDC supply and mounts directly on a 35 mm DIN rail. Hardware Specifications Parameter Specification Model CI810B 3BSE020520R1 Spare Model CI810B Product Type Fieldbus Communication Interface Manufacturer ABB Origin Sweden Weight 0.4 kg Dimensions 16.8 x 8.5 x 12 cm estimated shipping size Supply Voltage 24 VDC Isolation 1500 VDC Mounting 35 mm DIN rail, snap-on Operating Temp 0 deg C to +60 deg C Storage Temp -40 deg C to +85 deg C Humidity 5-95% RH, non-condensing Communication Interface AF100 fieldbus AF100 Modems 2 x twisted-pair modems Power Supply Connector 3BSC840098R1 Modulebus Terminator TB807, 3BSE008538R1 ABB Industrial Control Communication Characteristics The CI810B uses two AF100 twisted-pair modems to provide the physical communication interface for the AF100 fieldbus. Therefore, installation should maintain proper separation between communication wiring and high-energy power conductors. The module operates from a 24 VDC supply and provides 1500 VDC isolation. This isolation specification defines the stated electrical isolation capability between applicable circuits; it does not replace the system grounding requirements. The CI810B uses snap-on mounting for a 35 mm DIN rail. Consequently, the mounting rail should remain mechanically secure and electrically bonded according to the control cabinet design. Frequently Asked Questions (FAQ) Q: What fieldbus does the CI810B 3BSE020520R1 support?A: The supplied data identifies the CI810B as an AF100 Fieldbus Communication Interface with two AF100 twisted-pair modems. Q: What supply voltage does the CI810B require?A: The specified supply voltage is 24 VDC. The supplied data does not define the module's power consumption. Q: What mounting method does the CI810B use?A: The module mounts on a 35 mm DIN rail using a snap-on mounting arrangement. Field Installation Guidelines Verify that the cabinet provides a secure 35 mm DIN rail before mounting the module. Confirm the 24 VDC supply polarity and voltage before energizing the interface. Route AF100 twisted-pair communication wiring separately from high-voltage and high-current conductors. Use the specified connectors and terminal blocks supplied for the module configuration. Install the TB807 Modulebus Terminator where required by the applicable ABB system architecture. Maintain shield and grounding practices specified by the ABB installation documentation for the associated fieldbus network. Keep communication cable routing free from unnecessary loops and excessive proximity to switching power devices. Confirm all field wiring terminations before applying system power.
$199.00 $99.00
-
ABB ABB CI855K01 3BSE018106R1 MB 300 Dual Ethernet Port Kit
ABB CI855K01 3BSE018106R1 MB 300 Dual Ethernet Port Kit Configured for MasterBus 300 communication, the ABB CI855K01 3BSE018106R1 (CI855K01 MB 300 Dual Ethernet Port Kit) provides dual Ethernet connectivity for data exchange across ABB control system networks. The module uses two RJ45 ports and supports 10 Mbit/s transmission with a data rate of up to 200 datasets/s. Hardware Specifications Parameter Specification Model CI855K01 3BSE018106R1 Spare Model 3BSE018106R1 Brand ABB Product Type MB 300 Dual Ethernet Port Kit Communication Protocol MasterBus 300 (MB 300) Ethernet Ports 2 x RJ45, 8-pin Transmission Speed 10 Mbit/s Data Rate 200 datasets/s Operating Temperature Up to 55 deg C Protection Class IP20, according to EN60529 and IEC 529 Power Consumption 150 mA at 24 VDC Origin Sweden Weight 0.6 kg Estimated Dimensions 20.5 x 16 x 8.9 cm Shipment Location Xiamen, China MasterBus 300 Ethernet Communication The CI855K01 implements MasterBus 300 communication through two 8-pin RJ45 Ethernet ports. Therefore, the module provides two physical network interfaces for MB 300 data exchange. The specified transmission speed is 10 Mbit/s, while the stated data rate reaches 200 datasets/s. The communication interface operates from a 24 VDC supply and consumes 150 mA under the specified conditions. The module has an IP20 protection class according to EN60529 and IEC 529. Consequently, installation should place the hardware inside an enclosure or cabinet that provides appropriate environmental protection. Frequently Asked Questions Q: How many Ethernet ports does the ABB CI855K01 provide?A: The CI855K01 provides 2 Ethernet ports, each using an 8-pin RJ45 connector. Q: What communication protocol does the CI855K01 support?A: The module supports MasterBus 300 (MB 300) communication with a specified transmission speed of 10 Mbit/s. Q: What power consumption does the CI855K01 require?A: The specified power consumption is 150 mA at 24 VDC. Field Installation Guidelines Install the CI855K01 in a suitable control cabinet or enclosure because the specified protection class is IP20. Verify the 24 VDC supply before connecting the module. Use Ethernet cabling suitable for the specified RJ45 interfaces and route communication cables separately from high-voltage or high-current conductors. Maintain proper cable routing to reduce electromagnetic interference and avoid unnecessary cable stress at the RJ45 connectors. Confirm MasterBus 300 network connections before energizing the system. Check both Ethernet interfaces for correct physical connections during commissioning. Keep the module within the specified operating temperature limit of up to 55 deg C. Follow the applicable ABB system installation documentation for grounding, shielding, connector handling, and cabinet wiring practices.
$199.00 $99.00
Anda telah melihat 264 dari 1117 produk