    Keterangan

    ABB AO845 3BSE045584R1 Analog Output Module

    The ABB AO845 3BSE045584R1 serves as the primary AO845 Analog Output Module utilized to execute 4-20 mA signal output control across ABB S800 I/O system platforms. The module provides 8 unipolar analog output channels with HART communication support and supports single or redundant configuration through ModuleBus.

    Hardware Specifications

    Parameter Specification
    Model AO845 3BSE045584R1
    Brand ABB
    Origin Sweden
    Weight 0.21 kg
    Dimensions 45 mm W x 102 mm D x 119 mm H
    Operating Temp 0 to +55 deg C
    Power Consumption Typ. 3.5 W
    Product Type Analog Output Module
    Series ABB S800 I/O
    Signal Specification 4-20 mA
    Number of Channels 8 unipolar analog output channels
    HART Support Yes
    Redundancy Support Yes
    Resolution 12 bit
    Isolation Groupwise isolated from ground
    Output Load Maximum 750 ohm
    Output Error Maximum 0.1%
    Temperature Drift Maximum 50 ppm/deg C
    Update Cycle Time 10 ms
    Current Limiting Short circuit proof current limited output
    Maximum Field Cable Length 600 m
    Rated Insulation Voltage 50 V
    Dielectric Test Voltage 500 V AC
    Current Consumption +5 V ModuleBus Maximum 125 mA
    Current Consumption +24 V External 218 mA
    MTU Compatibility TU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852
    Keying Code DB
    Protection Class IP20 according to IEC 60529
    EMC Standard EN 61000-6-4 and EN 61000-6-2
    Safety Standard EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201

    ABB S800 I/O Backplane Communication and I/O Density Scaling

    The AO845 module operates within the ABB S800 I/O architecture and exchanges process data through the ModuleBus interface. The hardware supports I/O density scaling by providing eight analog output channels in a compact S800 module format. Additionally, redundant operation allows two modules to participate in a coordinated configuration where the ModuleBus master manages module status supervision.

    The module performs cyclic self-diagnostics during operation. External channel errors are generated when process power supply conditions are insufficient or when the measured output current does not match the configured value above the 1 mA threshold. Internal channel errors are reported when the output circuit cannot maintain the requested current value.

    Module-level diagnostics monitor output transistor faults, short circuits, checksum failures, internal power supply conditions, status link errors, watchdog operation, and incorrect OSP behavior. Therefore, the system can identify hardware execution faults through the module diagnostic interface.

    Frequently Asked Questions

    Q: Does the AO845 3BSE045584R1 support redundant operation?
    A: Yes. The AO845 supports redundant applications. In redundant configurations, the ModuleBus master supervises module status and commands the module to an error state when internal faults occur.

    Q: What type of field signals can the AO845 output?
    A: The module provides eight unipolar analog output channels with 4-20 mA signal capability and HART communication support.

    Q: How does the module handle output short circuits?
    A: The AO845 uses current-limited output circuitry with short circuit protection. Diagnostic functions report output transistor errors and channel faults.

    Field Installation Guidelines

    Install the AO845 module on compatible ABB S800 I/O MTUs according to the selected hardware configuration. Verify the MTU keying code before mounting the module to prevent incorrect module placement.

    Connect field wiring according to the approved terminal assignment. Maintain proper cable routing between analog signal wiring and high-energy conductors to reduce electromagnetic interference. Use appropriate shield grounding practices according to the installation standard of the control system.

    Before commissioning, verify the external process power supply, channel configuration, ModuleBus communication status, and diagnostic LED indications. Confirm that the connected field devices match the configured 4-20 mA output range.

    Spesifikasi

    • Merek: ABB

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama