Yokogawa AD5*D Terminal Board The Yokogawa AD5*D-0, also cataloged as the AD5*D Terminal Board, operates as a dedicated hardware component...
Baca selengkapnya
Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .
Hubungi kami: +86 135 995 07613
Tersedia pada hari kerja antara pukul 09.00 hingga 18.00
Email kami: sales2@industriaxplc.com
Tersedia 24/7 untuk pertanyaan dan dukungan
Keterangan
Yokogawa AD5*D Terminal Board
The Yokogawa AD5*D-0, also cataloged as the AD5*D Terminal Board, operates as a dedicated hardware component for signal termination and bridging between field devices and FIO modules within CENTUM VP and CENTUM CS 3000 systems.
Hardware Specifications
Parameter
Specification
ModelBrand
Yokogawa AD5*D
Origin
Japan
Weight
0.2 kg
Dimensions
3.2 cm × 12.5 cm × 13.0 cm
OperatingTemp
0 to 50 degC
OperatingHumidity
10% to 90% RH (Non-condensing)
MountingType
DIN-rail or panel mount
CompatibleSignalCable
Yokogawa AKB331
InsulationResistance
≥ 10 MΩ at 200 VDC; up to ≥ 10 MΩ at 500 VDC
WithstandingVoltage
200–500 VAC for 1 min (per module insulation class)
CorrosionResistance
ISA-S71.04 Class G3 (if code 6/F selected)
DCS-Specific Signal Characteristics
The AD5*D Terminal Board supports direct channel-to-channel isolation for digital and analog signals routed into FIO modules. Loop-level integration is compatible with 4-20 mA HART protocol signaling. Cold junction compensation is applicable when connected to thermocouple field devices, maintaining consistent voltage references across signal channels. Redundant digital I/O configurations are accommodated without cross-channel interference.
Frequently Asked Questions
Q: VnA: Can the AD5*D be hot-swapped while FIO modules are energized? A: No. Terminal boards require de-energized conditions during insertion or removal to maintain signal integrity and prevent transient overvoltage.
Q: VnA: What is the expected insulation performance for mixed analog and digital signal channels? A: Standard operation maintains ≥ 10 MΩ at 200 VDC. With module-specific configurations, insulation withstands up to 500 VDC without breakdown.
Q: VnA: Does the AD5*D support FOUNDATION Fieldbus or Profibus PA directly? A: The terminal board provides physical termination only; protocol-specific modules must handle digital communication. Electrical routing preserves signal isolation and integrity.
Field Installation Guidelines
Mount the AD5*D on a standard DIN-rail or control panel using screws with firm torque.
Ensure proper grounding of signal shields to reduce EMI.
Route digital and analog signal cables separately to avoid crosstalk.
Maintain recommended bend radius for AKB331 cables to prevent conductor strain.
Confirm power isolation on FIO modules before terminal board installation.
If installing in hazardous areas, verify explosion protection and corrosion-resistant code compliance.