    Keterangan

    Yokogawa ALR121-S53 Serial Communication Module

    Configured for serial data communication in Yokogawa Field Control Station architectures, the Yokogawa ALR121-S53 (ALR121 Serial Communication Module) provides direct physical/electrical execution of RS-422 and RS-485 communication functions between control stations and connected subsystems. The module supports dual communication ports, start-stop synchronization, ASCII or binary transmission formats, and half-duplex operation for subsystem integration.

    Suffix Breakdown & Model Matrix

    Model Element Description
    ALR121 Serial Communication Module
    -S Standard type
    5 Basic type without explosion protection
    3 ISA Standard G3 corrosion-resistant specification

    Hardware Specifications

    Parameter Specification
    Model ALR121-S53
    Brand Yokogawa
    Origin Japan
    Product Type Serial Communication Module
    Interface RS-422 / RS-485
    Number of Ports 2
    Communication Method Half-duplex
    Synchronization Method Start-stop synchronization
    Transmission Code ASCII / Binary
    Character Length 7 bits / 8 bits
    Stop Bit Length 1 bit / 2 bits
    Parity Check None / Even / Odd
    Transmission Speed 1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps
    Maximum Transmission Distance Up to 1200 m
    RS-485 Topology Multipoint communication
    RS-422 Topology Point-to-point communication
    Current Consumption 0.5 A
    Weight Approx. 0.34 kg
    Mounting Compatibility AFV30, AFV40, ANB10, ANB11 and compatible field control units
    Wiring Method Terminal block with M4 screw connections

    Channel Isolation and DCS Communication Integration

    As a Yokogawa DCS communication module, the ALR121-S53 is intended for subsystem-level serial data exchange through RS-422 or RS-485 physical layers. Communication parameters including baud rate, parity, character length, and stop bits can be configured to match connected subsystem requirements.

    The module supports ASCII and binary transmission modes and can be integrated with Modbus RTU slave communication functions where system configuration permits. Dual communication ports allow independent connections to external controllers, intelligent devices, or subsystem interfaces within the same control platform.

    Frequently Asked Questions

    Q: Does the ALR121-S53 support both RS-422 and RS-485 networks?
    A: Yes. The module supports RS-422 point-to-point communication and RS-485 multipoint communication through its serial communication interfaces.

    Q: What is the maximum supported communication distance?
    A: The specified total extended transmission distance is up to 1200 m when suitable communication cable and installation practices are applied.

    Q: Can communication parameters be configured for different field devices?
    A: Yes. The module supports selectable baud rates, parity settings, character lengths, stop bits, and transmission formats according to system configuration requirements.

    Field Installation Guidelines

    • Verify that RS-422 or RS-485 network topology matches the connected subsystem design before commissioning.
    • Use shielded communication cable recommended by the system documentation, such as approved multi-pair shielded industrial communication cable.
    • Route communication wiring separately from high-voltage power cables to reduce electromagnetic interference.
    • Ground cable shields according to plant grounding standards and DCS installation requirements.
    • Confirm baud rate, parity, character length, and stop-bit settings are identical at both communication endpoints before energizing the network.
    • Tighten terminal block connections according to approved maintenance procedures and inspect periodically for loosened conductors.
    • Observe controller cabinet environmental requirements specified by the host control system documentation.

    Spesifikasi

    • Merek: Yokogawa

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun