Yokogawa ALR121-S00 S1 Serial Communication Module The Yokogawa ALR121-S00 S1, also cataloged as the ALR121 Serial Communication Module, operates as... Baca selengkapnya

SKU: ALR121-S00 S1
Negara asal: JAPAN

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Yokogawa ALR121-S00 S1 Serial Communication Module

    The Yokogawa ALR121-S00 S1, also cataloged as the ALR121 Serial Communication Module, operates as a dedicated hardware component for serial data exchange via RS-422, RS-485, and RS-232C interfaces within CENTUM VP and CENTUM CS 3000 distributed control systems.

    Hardware Specifications

    Parameter Specification
    Brand Yokogawa
    Origin Japan
    Weight Approx. 0.30 kg
    Dimensions Not specified in source documentation
    Operating Temp 0 to 50 degC (32 to 122 degF)
    Power Consumption Max. 0.5 A at 5 V DC
    Number of Ports 2 (Port 1, Port 2)
    Interface Standards RS-422, RS-485 (2-wire/4-wire), RS-232C (software selectable per port)
    Transmission Speed 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
    Maximum Cable Length RS-422/485: 1200 m; RS-232C: 15 m
    Connection Method AKB161 or AKB162 cables

    Fieldbus Integration and Channel Isolation

    This module supports deterministic communication performance through CENTUM VP backplane bus integration, maintaining consistent data throughput for connected subsystems. Each port operates with independent electrical isolation characteristics, preventing ground loop formation when interfacing with heterogeneous field instrumentation. The hardware complies with standard 4-20 mA loop signaling conventions where applicable in hybrid analog-digital architectures, ensuring compatibility with existing process measurement devices.

    Frequently Asked Questions

    Q: Does the ALR121-S00 S1 support hot-swapping without interrupting DCS operations?

    A: Yes. The module can be replaced online without powering down the station, provided the redundant configuration is active to maintain bumpless operation.

    Q: What is the maximum cable length supported for RS-485 connections?

    A: The module supports up to 1200 meters for RS-422/485 links, depending on cable quality and network topology.

    Q: Are both ports independently configurable for different serial standards?

    A: Yes. Each port can be individually set to RS-422, RS-485, or RS-232C via software configuration.

    Field Installation Guidelines

    Mount the module into the designated CENTUM VP or CS 3000 I/O slot using correct ESD precautions. Use shielded twisted-pair cabling for RS-422/485 connections, grounding the shield at one end only to minimize noise pickup. Maintain separation from high-voltage power wiring to prevent electromagnetic interference. Verify termination resistor settings according to the connected device specifications before energizing the system.

    Spesifikasi

    • Merek: Yokogawa

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama