Keterangan
Schneider Electric 140XTS00206 Modicon Quantum Terminal Strip
Configured for signal routing in Modicon Quantum systems, the Schneider Electric 140XTS00206 (base model 140XTS002) terminal strip provides direct physical and electrical execution between Quantum I/O interfaces and SUB-D connectors. The assembly integrates a 1.8 m pre-terminated cable for fixed wiring paths within controlled enclosures.
Hardware Specifications
Parameter
Specification
Model Brand
Schneider Electric
Origin
France
Weight
1.31 lbs (0.60 kg)
Dimensions
Not specified
Operating Temp
0 to 40 degC
Power Consumption
Not applicable
Cable Length
1.8 m
Connector Type
1 x Quantum I/O connector, 1 x SUB-D 50-pin
Electrical Isolation
Not specified
Backplane Bus Communication Velocity Licensing
The 140XTS00206 operates within the deterministic backplane bus architecture of the Modicon Quantum platform. Communication velocity licensing defines the maximum data throughput permitted between I/O modules and the central processor over the proprietary parallel backplane. Licensing does not alter electrical characteristics but governs logical bandwidth allocation. Firmware revisions must match the licensed throughput class to ensure consistent timing performance across redundant processors.
Frequently Asked Questions
Q: Does the 140XTS00206 support hot-swapping during system operation?
A: No. Removal or insertion must occur only after de-energizing the associated I/O module to prevent transient backplane faults.
Q: What is the maximum altitude for operation without derating?
A: Operation is specified up to 1000 meters above sea level without performance reduction.
Q: Is firmware flash compatibility required for this terminal strip?
A: Firmware compatibility applies to the connected I/O module rather than the terminal strip itself; verify module firmware against the installed Quantum CPU revision.
Field Installation Guidelines
Mount the terminal strip within enclosures that maintain ambient conditions within 0–40 degC and below 80% relative humidity, non-condensing. Route the 1.8 m cable away from high-current conductors to minimize electromagnetic coupling. Ensure connector screws are torqued to manufacturer-specified values. Verify pin alignment before mating the SUB-D 50-pin connector to prevent contact deformation. Do not exceed the rated bending radius of the cable during installation.