Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Tachometer Monitor Module | Bently Nevada 3300/50-02-01-00-00

Tachometer Monitor Module | Bently Nevada 3300/50-02-01-00-00

Formulir produk

Bently Nevada 3300/50 Tachometer Monitor Module The Bently Nevada 3300/50-02-01-00-00 also cataloged as the 3300/50 Tachometer Monitor Module operates as a dedicated hardware component... Baca selengkapnya

SKU: 3300/50-02-01-00-00
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 3300/50 Tachometer Monitor Module

    The Bently Nevada 3300/50-02-01-00-00 also cataloged as the 3300/50 Tachometer Monitor Module operates as a dedicated hardware component for zero-speed detection and shaft rotational speed processing within the 3300 monitoring rack system. Configured for direct tachometer signal conditioning, the Bently Nevada 3300/50-02-01-00-00 (3300/50 Tachometer Monitor Module) provides direct electrical execution of proximity probe and magnetic pickup inputs for low-speed threshold evaluation.

    Suffix Breakdown & Model Matrix

    Code Segment Description Configuration
    -02 Tachometer Type Zero Speed Tachometer
    -01 Relay Output 5 A Epoxy-Sealed SPDT Relays
    -00 Agency Approval None
    -00 Safety Barriers Not Installed

    Hardware Specifications

    Parameter Specification
    ModelBrand Bently Nevada 3300/50-02-01-00-00
    Origin USA
    Weight 1.5 kg
    Dimensions 51 mm x 203 mm x 330 mm
    OperatingTemp -20 degC to +65 degC
    PowerConsumption 2.5 W
    Input Channels Up to 2 transducer inputs
    Compatible Sensors 3300 / 7200 / 3000 proximity probes, magnetic pickups
    Input Impedance 10 kOhm nominal
    Speed Range 1 to 99999 rpm (system dependent)
    Output Signal 4-20 mA / voltage output selectable
    Relay Output SPDT, 5 A epoxy sealed

    Eddy-Current Probe Scaling and Signal Integrity Control

    The Bently Nevada 3300/50 module applies eddy-current proximity probe scaling based on calibrated gap voltage validation referenced to negative DC bias targets (commonly -10 VDC operating region in probe conditioning circuits). Signal linearization is maintained through internal conversion logic aligned with rotor dynamic displacement interpretation. Cross-talk suppression is implemented at the channel conditioning stage to reduce phase contamination between redundant tachometer inputs, particularly when dual probe voting logic is enabled. Magnetic pickup inputs exhibit reduced fidelity at near-zero rotational velocity due to coil amplitude decay, making eddy-current transducer systems the preferred measurement source for zero-speed confirmation.

    Frequently Asked Questions

    Q: Does the 3300/50 support hot-swapping in the rack system?
    A: The module is not designed for live insertion under load conditions. Backplane power should be removed prior to installation or removal to avoid transient signal corruption.

    Q: What is the input redundancy behavior between dual channels?
    A: The module applies internal voting logic between two independent transducer inputs. Discrepancy handling is governed by threshold comparison and fails to a conservative zero-speed state under signal loss conditions.

    Q: Can magnetic pickups be used for zero-speed detection?
    A: Magnetic pickups are supported but exhibit reduced resolution near zero rpm due to low induced voltage amplitude, limiting accuracy in true zero-speed conditions.


    Field Installation Guidelines

    Ensure backplane power isolation before inserting the module into the 3300 rack. Maintain shield continuity for all proximity probe signal cables and terminate shields at a single-point ground to prevent ground loop formation. Signal wiring should be routed separately from high-voltage or VFD conductors to minimize electromagnetic interference coupling. Verify probe gap calibration using manufacturer-specified reference targets prior to commissioning. All terminal connections must maintain mechanical torque retention to prevent micro-disconnection under vibration environments.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun