    Keterangan

    Description

    The Schneider Electric DEA 106 is a high-performance analog input module engineered for precise signal acquisition in industrial automation environments. Designed for compatibility with TSX and Modicon PLC platforms, this module provides reliable signal conditioning and data conversion for critical process variables. Its robust design ensures consistent operation in demanding control applications.

    Features

    • Six isolated input channels for enhanced signal integrity and noise immunity.
    • Configurable input ranges supporting both 0-10V voltage and 4-20 mA current signals.
    • High-precision 12-bit resolution for accurate process monitoring.
    • Fast conversion time of 2.5 ms per channel to support dynamic control loops.
    • Galvanic isolation of 1500V between the input channels and the backplane.

    Technical Specifications

    Manufacturer Schneider Electric
    Model DEA 106
    Type Analog Input Module
    Number of Channels 6 (Isolated)
    Input Ranges 0-10V, 4-20 mA
    Resolution 12 Bits
    Conversion Time 2.5 ms per channel
    Isolation 1500V (Channel to Backplane)
    Weight 0.28 kg

    Installation Guidelines

    • Ensure the PLC rack power is disconnected before installing or removing the module.
    • Mount the module securely in the designated rack slot to ensure proper backplane connection.
    • Use shielded twisted-pair cabling for analog signal inputs to minimize electromagnetic interference (EMI).
    • Maintain proper spacing within the cabinet to allow for adequate ventilation and heat dissipation.
    • Verify that all signal wiring is correctly terminated and that input ranges are configured according to the specific application requirements.

    FAQ

    What is the primary function of the DEA 106 module?

    The DEA 106 is an analog input module used to convert external voltage or current signals from field sensors into digital data for processing by Schneider Electric PLC systems.

    Does this module require external power for the inputs?

    The DEA 106 is designed to interface with standard 0-10V and 4-20 mA signals. Please refer to your specific system wiring diagram to determine if your field devices require a separate loop power supply.

    Is the DEA 106 compatible with all Modicon platforms?

    The DEA 106 is specifically designed for integration with compatible TSX and Modicon PLC platforms. Always verify your specific CPU and rack compatibility before installation.

    Spesifikasi

    • Merek: Schneider

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun