SKU: 140DDO15310
Negara asal: France

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Schneider Electric 140DDO15310 Modicon Quantum TTL Discrete Output Module

    The Schneider Electric 140DDO15310, also cataloged as the 140DDO15310 TTL Discrete Output Module, operates as a dedicated hardware component for 5 VDC TTL discrete output switching within the Modicon Quantum automation platform. The module provides 32 positive (sink) TTL output channels organized into four isolated groups for direct field signal execution through the Quantum backplane.

    Hardware Specifications

    Parameter Specification
    Model 140DDO15310
    Brand Schneider Electric
    Product Series Modicon Quantum
    Product Type TTL Discrete Output Module
    Origin Not specified
    Discrete Outputs 32 TTL outputs
    Output Grouping 4 groups of 8 channels
    Output Type Positive (sink), TTL
    Rated Output Voltage 5 V DC
    Supply Voltage 4 to 5.5 V DC
    Voltage State 1 <= 0.2 V guaranteed
    Addressing Requirement 2 output words
    Maximum Load Current <= 75 mA per point; <= 600 mA per group; <= 2.4 A per module
    Internal Pull-up Resistor 440 Ohm
    Response Time <= 250 us (0 to 1 and 1 to 0, resistive load)
    Absolute Maximum Output 15 V DC decaying pulse for 0.0013 s
    Surge Current 750 A, 0.5 ms between each point
    Protection Internal fuse, transient voltage suppression
    Fault Indication Blown fuse, loss of field power
    Local Indicators 32 green output LEDs, 1 red fault LED, 1 green Active LED
    Isolation 500 Vrms between groups for 1 minute
    Bus Current Requirement 350 mA
    Supply Current 0.4 A
    Current Consumption 2800 mA at 5 V DC
    Power Consumption 4 W
    Dimensions Not specified
    Weight 0.45 kg
    Operating Temp 0 to 60 degC
    Storage Temp -40 to 85 degC
    Relative Humidity 95 % non-condensing
    Operating Altitude <= 5000 m
    Certifications CE, C-Tick, FM Class 1 Division 2, GOST, RMRS
    Standards CSA C22.2 No. 142, UL 508

    Backplane Communication and I/O Density

    The module exchanges output data through the Modicon Quantum backplane using a two-output-word addressing structure. Thirty-two TTL output channels are integrated within a standard Quantum module format while maintaining group isolation of 500 Vrms. Status reporting is provided through dedicated output LEDs together with Active and Fault indicators for module diagnostics.

    Frequently Asked Questions

    Q: Does the module support hot swapping during operation?
    A: The supplied technical data does not specify hot-swap capability. Installation and removal should follow the procedures defined for the Modicon Quantum platform and system maintenance practices.

    Q: How are the output channels electrically organized?
    A: The module contains 32 TTL sink outputs divided into four independent groups of eight channels, with isolation rated at 500 Vrms between groups for one minute.

    Q: What protection mechanisms are integrated on the outputs?
    A: Each module incorporates internal fuse protection, transient voltage suppression, and diagnostic indication for blown fuse and field power loss.

    Field Installation Guidelines

    • Verify that the system supply voltage remains within 4 to 5.5 V DC before energizing the module.
    • Observe the specified current limits for each output point, group, and the complete module to prevent overload.
    • Separate field output wiring from high-energy power conductors to minimize electrical interference.
    • Ensure the protective earth and cabinet grounding system are correctly connected before commissioning.
    • Confirm correct seating of the module in the Quantum backplane and verify Active and output status LEDs during startup.
    • Replace blown fuses only after the source of the overload or wiring fault has been identified and corrected.

    Spesifikasi

    • Merek: Schneider Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun