ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly The ICS Triplex TC-301-02-2M5, also cataloged as the TC-301-02-2M5 Trusted System Communication... Baca selengkapnya

SKU: TC-301-02-2M5
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly

    The ICS Triplex TC-301-02-2M5, also cataloged as the TC-301-02-2M5 Trusted System Communication Cable Assembly, operates as a dedicated hardware component for TMR communication signal transfer within the ICS Triplex Trusted Safety System. It provides physical interconnection between Trusted processor expansion interfaces.

    Hardware Specifications

    Parameter Specification
    Model TC-301-02-2M5
    Brand ICS Triplex (Rockwell Automation)
    Origin United Kingdom
    Product Type Trusted System Communication / Expansion Cable Assembly
    Cable Length 2.5 m
    Cable Type Screened Category 6 Plus cable with LSZH outer sheath
    Processor Side Connector 96-way Type C connector with integrated earth braid
    Adapter Side Connector 12-way LEMO plug
    Signal Interface Trusted proprietary TMR expansion communication bus
    Shielding 360-degree EMI and RFI shielding structure
    Weight Approximately 0.85 kg to 1.0 kg
    Dimensions Cable assembly, 2.5 m length
    Operating Temp -5 deg C to +60 deg C
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95% non-condensing
    Power Consumption Passive cable assembly, no independent power consumption

    TMR Safety Communication Interface

    The TC-301-02-2M5 cable assembly supports the ICS Triplex Trusted triple modular redundancy communication architecture. It transfers synchronized data signals between Trusted system expansion components, such as the Trusted Expander Processor and Expander Interface Adapter.

    Furthermore, the cable maintains signal integrity through a screened construction and dedicated grounding path. The integrated shielding structure reduces electromagnetic interference during operation and supports stable TMR data exchange between redundant hardware nodes.

    The Trusted platform uses a 2oo3 voting architecture to execute fault-tolerant safety functions. Therefore, the TC-301-02-2M5 provides the physical communication path required for coordinated triplicated signal handling within SIL3 safety applications.

    Frequently Asked Questions (FAQ)

    Q: What components does the TC-301-02-2M5 connect within the Trusted system?
    A: The TC-301-02-2M5 connects Trusted expansion communication interfaces, typically linking a Trusted Expander Processor with an Expander Interface Adapter through the proprietary TMR bus.

    Q: Does the TC-301-02-2M5 require external power input?
    A: No. The TC-301-02-2M5 is a passive communication cable assembly and does not include active electronic circuits or independent power requirements.

    Q: How should the cable shielding be installed?
    A: The cable shielding and earth braid should maintain proper grounding continuity according to the Trusted system installation requirements. Avoid routing the cable parallel to high-current power conductors to reduce electromagnetic coupling.

    Field Installation Guidelines

    • Install the TC-301-02-2M5 according to the Trusted system hardware installation manual and approved cabinet wiring practices.
    • Verify that both connector interfaces are fully seated before system commissioning.
    • Maintain the cable bend radius specified for the cable construction to prevent mechanical stress on connectors and shielding layers.
    • Connect the integrated earth braid according to the cabinet grounding scheme.
    • Separate communication cable routing from high-voltage and high-current wiring where possible.
    • Inspect connector contacts for contamination, mechanical damage, or improper engagement before installation.
    • Do not modify connector assemblies or cable shielding structures in the field.

    Spesifikasi

    • Merek: ICS Triplex

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama