Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

ICS Triplex T8122 Trusted Processor Interface Adapter

ICS Triplex T8122 Trusted Processor Interface Adapter

Formulir produk

ICS Triplex T8122 Trusted Processor Interface Adapter Configured for physical serial signal interfacing in the Trusted TMR system, the ICS... Baca selengkapnya

SKU: T8122
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    ICS Triplex T8122 Trusted Processor Interface Adapter

    Configured for physical serial signal interfacing in the Trusted TMR system, the ICS Triplex T8122 (T8122 Processor Interface Adapter) provides electrical access to processor communication ports. It supports RS-422/RS-485 serial communication and IRIG-B time synchronization while maintaining specified electrical isolation between external connections and the processor interface.

    Suffix Breakdown & Model Matrix

    The supplied documentation identifies T8122 as a single fixed model. No suffix or ordering-code breakdown is specified, so no additional model variants are inferred.

    Hardware Specifications

    Parameter Specification
    Model T8122
    Brand ICS Triplex
    Product Series Trusted TMR System
    Product Type Processor Interface Adapter / Communications Interface Module
    Compatibility Trusted TMR Processors, including T8110B and T8111
    Power Supply Directly powered from the Trusted TMR Processor
    Power Dissipation 0.1 W
    Serial Interfaces 3 x RS-422 / RS-485
    Time Synchronization Interface IRIG-B
    Supported Protocols Modbus RTU; Modbus Slave; optional Modbus Master
    Electrical Isolation 50 V reinforced continuous; 250 V basic fault
    Isolation Type Test 2436 VDC for 60 seconds
    Operating Temperature 0 deg C to +60 deg C
    Hot-Swappable Yes, subject to system replacement procedures
    Certifications / Application Rating CE, UL, CSA; SIL 3 safety-rated application support

    TMR Safety Interface and Galvanic Isolation

    The T8122 operates as an interface component within the ICS Triplex Trusted TMR architecture. The associated Trusted processors use triple modular redundancy to maintain fault-tolerant control execution. The T8122 provides specified galvanic isolation between external serial interfaces and the processor-side circuitry.

    The serial interface supports RS-422 and RS-485 electrical signaling for Modbus communications. In addition, the IRIG-B port provides a dedicated interface for time synchronization. Therefore, external communication wiring remains electrically separated according to the stated isolation ratings.

    The isolation system specifies 50 V reinforced continuous isolation and 250 V basic fault isolation. A 2436 VDC withstand test for 60 seconds further defines the stated isolation qualification.

    Frequently Asked Questions (FAQ)

    Q: Which processors can interface with the T8122?
    A: The supplied data identifies the Trusted TMR T8110B and T8111 processors as compatible processor interfaces.

    Q: What serial interfaces does the T8122 provide?
    A: The module provides three RS-422 / RS-485 serial ports for supported Modbus communications.

    Q: Can the T8122 be replaced while the system remains powered?
    A: The supplied specification identifies the T8122 as hot-swappable. Replacement must follow the applicable Trusted system maintenance procedure.

    Field Installation Guidelines

    • Install the T8122 only in the specified Trusted TMR system hardware arrangement.
    • Confirm processor compatibility before connecting communication wiring.
    • Route RS-422 / RS-485 communication cables separately from high-voltage and high-current power conductors.
    • Maintain appropriate cable shielding and grounding practices for the installed communication network.
    • Terminate RS-422 / RS-485 networks according to the applicable network topology and equipment documentation.
    • Keep external communication wiring physically controlled to reduce electromagnetic coupling into serial signal circuits.
    • Connect IRIG-B wiring according to the selected time-synchronization interface configuration.
    • Do not bypass or modify the specified electrical isolation barriers.
    • Verify connector seating and module engagement before returning the system to service.
    • For hot-swap replacement, follow the Trusted system maintenance procedure and verify the module status after installation.

    Spesifikasi

    • Merek: ICS Triplex

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun