Honeywell MU-TAMR02 Analog Input Terminal Assembly Module Configured for redundant analog signal termination in Honeywell TDC 3000 and Experion PKS...
Baca selengkapnya
Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .
Hubungi kami: +86 135 995 07613
Tersedia pada hari kerja antara pukul 09.00 hingga 18.00
Email kami: sales2@industriaxplc.com
Tersedia 24/7 untuk pertanyaan dan dukungan
Keterangan
Honeywell MU-TAMR02 Analog Input Terminal Assembly Module
Configured for redundant analog signal termination in Honeywell TDC 3000 and Experion PKS platforms, the Honeywell MU-TAMR02 (MU-TAMR02 Analog Input Terminal Assembly Module) provides direct field wiring interface execution between 4-20 mA instrumentation loops and HPM I/O processing modules.
Hardware Specifications
Parameter
Specification
Model
MU-TAMR02
Brand
Honeywell
Origin
USA
Module Type
Redundant Analog Input Terminal Assembly Module
Part Number
51301376-100 / 51301376-200
System Compatibility
Honeywell TDC 3000, Experion PKS, Process Manager, High-Performance Process Manager
Function
Analog input field termination and signal routing
Channel Capacity
16 analog input channels
Signal Type
4-20 mA DC / 1-5 V DC
Configuration
Redundant I/O termination configuration
Termination Type
Screw terminal blocks / compression terminals
Mounting Type
Cabinet terminal panel or DIN rail mounting arrangement
Operating Temp
0 deg C to +60 deg C
Storage Temp
-40 deg C to +85 deg C
Relative Humidity
5% to 95% non-condensing
Weight
Not specified by manufacturer
Dimensions
Not specified by manufacturer
Power Consumption
Passive termination assembly; no independent power input specified
DCS Analog Signal Interface and Isolation Features
The MU-TAMR02 operates as a field termination interface within Honeywell process control architectures. It accepts standard analog instrumentation signals and routes them to associated HPM or Process Manager I/O modules.
The assembly supports Honeywell DCS analog input configurations based on 4-20 mA HART loop protocol compatibility at the system I/O level. In addition, the termination design supports organized field wiring separation and channel-to-channel signal management when installed with compatible I/O modules.
The redundant TAMR configuration allows two I/O processing paths to access the same field termination point. Therefore, the control system can maintain signal availability during a single I/O path fault condition.
Frequently Asked Questions
Q: Does the MU-TAMR02 provide independent signal measurement processing? A: No. The MU-TAMR02 functions as a terminal assembly interface. Analog signal conversion and processing occur inside the connected Honeywell I/O modules.
Q: Can the MU-TAMR02 support redundant I/O configurations? A: Yes. The TAMR designation indicates a redundant terminal assembly arrangement designed for connection with redundant Honeywell I/O processing configurations.
Q: Does the MU-TAMR02 require separate field power wiring? A: No independent power supply connection is specified. The assembly provides field signal termination and routing functions for compatible Honeywell I/O systems.
Field Installation Guidelines
Install the MU-TAMR02 inside an approved Honeywell control cabinet or compatible terminal panel assembly.
Verify terminal assignments before connecting field analog instruments to prevent incorrect channel mapping.
Use shielded instrumentation cable for low-level analog signal wiring where required by the plant grounding specification.
Connect cable shields according to the site grounding practice and avoid multiple grounding points that may introduce signal noise.
Separate analog signal wiring from high-voltage power cables and switching circuits to reduce electromagnetic interference.
Confirm redundant I/O wiring paths before system commissioning to ensure correct signal routing.
Inspect terminal connections periodically for mechanical tightness and signs of corrosion in field environments.