Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Honeywell MU-TAIH52 Redundant High-Level Analog Input Field Termination Assembly

Honeywell MU-TAIH52 Redundant High-Level Analog Input Field Termination Assembly

Formulir produk

Honeywell MU-TAIH52 Redundant High-Level Analog Input Field Termination Assembly Configured for redundant high-level analog input signal termination in Honeywell TDC... Baca selengkapnya

SKU: MU-TAIH52 51304337-200
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell MU-TAIH52 Redundant High-Level Analog Input Field Termination Assembly

    Configured for redundant high-level analog input signal termination in Honeywell TDC 3000 and TPS systems, the Honeywell MU-TAIH52-200 (MU-TAIH52 Redundant High-Level Analog Input FTA) provides direct field wiring interface and electrical signal routing between smart transmitters and I/O Processors.

    Hardware Specifications

    Parameter Specification
    Model MU-TAIH52
    Brand Honeywell
    Origin USA
    Operating Temp 0 deg C to +60 deg C
    Power Consumption Passive field termination assembly; no independent power consumption specified
    Part Number 51304337-200
    Module Type Redundant High-Level Analog Input / Smart Transmitter Interface FTA
    System Compatibility Honeywell TDC 3000 / TotalPlant Solution (TPS)
    Supported Controllers Process Manager (PM), Advanced Process Manager (APM), High-Performance Process Manager (HPM)
    Input Channels 16 channels
    Input Signal Type 4-20 mA DC / Smart Transmitter DE protocol
    Redundancy Configuration Dual redundant HLAI or STI input card interface
    Mounting Method DIN rail / cabinet mounting
    Field Connection Screw terminal field wiring interface
    Storage Temperature -40 deg C to +85 deg C
    Humidity Range 5% to 95% RH, non-condensing

    4-20 mA HART Loop Interface and Channel Isolation

    The MU-TAIH52 operates as a field termination interface for Honeywell analog input architectures. It routes 4-20 mA current signals and Smart Transmitter Interface signals from field devices to redundant input processing cards.

    Furthermore, the assembly supports transmitter communication paths used in process instrumentation applications. The termination design separates field wiring connections and system-side interfaces to maintain controlled signal transmission. Channel-to-channel isolation depends on the connected I/O card architecture and system configuration.

    The redundant arrangement allows two compatible input paths to receive field signals through the termination assembly. Therefore, maintenance activities on one processing path can occur while the paired path remains connected according to the configured TPS or TDC 3000 architecture.

    Frequently Asked Questions

    Q: Does the MU-TAIH52 provide signal conversion from field analog input signals?

    A: No. The MU-TAIH52 functions as a Field Termination Assembly. It terminates and routes field signals but does not perform analog-to-digital conversion.

    Q: Can the MU-TAIH52 operate with non-redundant input cards?

    A: The assembly is designed for redundant HLAI or STI input configurations. Compatibility depends on the installed Honeywell I/O processor and cabinet configuration.

    Q: Does the MU-TAIH52 require separate field power wiring?

    A: The FTA does not contain an independent power supply. Field transmitter power requirements depend on the connected transmitter circuit and associated I/O hardware.

    Field Installation Guidelines

    • Install the MU-TAIH52 inside the designated Honeywell control cabinet or marshalling enclosure using the approved DIN rail mounting arrangement.
    • Verify terminal assignments before connecting field transmitters or Smart Transmitter Interface wiring.
    • Separate analog signal wiring from high-voltage power cables to reduce electromagnetic interference.
    • Connect cable shields according to the plant grounding standard and Honeywell cabinet wiring practices.
    • Confirm redundancy pairing between the FTA and the associated HLAI or STI input cards before commissioning.
    • Check field loop polarity and continuity before applying system power.
    • Verify transmitter communication status after installation through the connected Honeywell control system diagnostics.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama